AXL SE PSDI8/3 - Safety module
Axioline Smart Elements, Digital input module, Functional safety, PROFIsafe, only for connection to Phoenix Contact or Siemens controller, Safe digital inputs: 4 (2-channel assignment), 8 (1-channel assignment), 24 V DC, connection technology: 3-conductor, degree of protection: IP20
- Up to SIL 3 in accordance with EN 61508
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
- 8 safe inputs for 1-channel assignment
- 4 safe inputs for 2-channel assignment
Technical Specifications
Dimensions
Width | 14.9 mm |
Height | 62.2 mm |
Depth | 62 mm |
Smart Element interface
Number of interfaces | 1 |
Connection Method | Card edge connector |
Transmission Speed | See system in which you use the Smart Element. |
Module
Input address area | 6 Byte (PROFIsafe 2.6.1) |
Output address area | 5 Byte (PROFIsafe 2.6.1) |
Digital:
Input name | Safe digital inputs |
Description of the input | EN 61131-2, type 3 |
Number of Inputs | 4 (2-channel assignment) |
Number of Inputs | 8 (1-channel assignment) |
Cable Length | max. 200 m (200 m from the clock output to the safe input (total based on forward and return path)) |
Connection Method | Push-in connection |
Connection technology | 3-conductor |
Input voltage range "0" signal | -3 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | typ. 2.7 mA |
Input filter time | 1.5 ms |
Input filter time | 3 ms (Default) |
Input filter time | 5 ms |
Input filter time | 15 ms |
Protective circuit | Polarity reversal protection of the inputs; Diode |
Product properties
Product family | Axioline Smart Elements |
Application | Functional safety |
Application | PROFIsafe |
Application | only for connection to Phoenix Contact or Siemens controller |
Type | modular |
Mounting Position | any |
Operating mode | PROFIsafe 2.4, PROFIsafe 2.6.1 |
Insulation characteristics
Overvoltage category | II (IEC 60664-1) |
Pollution degree | 2 (EN 60664-1) |
Electrical properties
Transmission medium | Copper |
Potentials
Protection | external fusing via the system in which the Smart Element is used |
Protective circuit | Surge protection of the supply voltage; electronic (35 V, 0.5 s) |
Protective circuit | Polarity reversal protection of the supply voltage; via the system in which the Smart Element is used |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 140 mA (at UBus 5 V DC) |
Current draw | typ. 101 mA (at UBus 5 V DC) |
Potentials: Communications power supply of the Smart Elements (USE)
Supply Voltage | using card edge connectors |
Potentials: I/O supply (UP)
Supply Voltage | 24 V DC (using card edge connectors) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 12 mA (Power supply from Up with 30 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2) |
Current draw | typ. 9 mA (Power supply from Up with 24 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2) |
Current consumption | min. 8 mA (Power supply from Up with 19.2 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2) |
Power consumption | max. 360 mW |
Power consumption | min. 154 mW |
Connection technology
Connection name | I/O |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
I/O
Connection Method | Push-in connection |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor cross section, rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Degree of protection at installation location | min. IP54 |
Air pressure (operation) | 70 kPa ... 108 kPa |
Air pressure (storage/transport) | 66 kPa ... 108 kPa |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Air clearances and creepage distances
Air clearances and creepage distances | IEC 60664-1 |
Mounting
Mounting Type | Smart Element slot |
Mounting Position | any |
Accessories
- 1031721 - Crimping pliers, contact connection type: Insulated and uninsulated ferrules, standards/specifications: DIN 46228-1, DIN 46228-4, UL 486F, form A, E, F, min. cross section: 0.14 mm2, max. cross section: 10 mm2, for TWIN ferrules up to 2 x 4 mm2, automatic cross section adjustment, rotating die, lateral and frontal insertion, compression: Trapezoidal crimp, black/green
- 1134913 - Crimping pliers, contact connection type: Insulated and uninsulated ferrules, standards/specifications: DIN 46228-1, DIN 46228-4, min. cross section: 0.14 mm2, max. cross section: 10 mm2, For TWIN ferrules up to 2 x 4 mm2, automatic cross section adjustment, frontal insertion, compression: Trapezoidal crimp, black
Why Proax for Phoenix Contact 1079241?
Proax is an authorized distributor of Phoenix Contact 1079241 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1079231 - Axioline Smart Elements, Digital output module, Functional safety, PROFIsafe, only for connection to Phoenix Contact or Siemens controller, Safe digital outputs: 2 (2-channel assignment), 4 (1-channel assignment), 24 V DC, 2 A, connection technology: 2-conductor, degree of protection: IP20
- 1182068 - Axioline Smart Elements, Temperature recording module, Analog inputs: 4 (Inputs for thermocouples or linear voltage), connection technology: 2-conductor (shielded, twisted pair), External cold junction (can also be used as an additional Pt 100 sensor input): 1, connection technology: 4-conductor, degree of protection: IP20