Official Distributor
SKU
Series AXL-SE-DO
AXL SE DO16/1 NPN - Module TOR
Axioline Smart Elements, Module de sortie numérique, Sorties TOR: 16 (NPN), 24 V DC, 500 mA, connectique: 1 fil, indice de protection: IP20
- 16 sorties TOR, commutation type npn
- 24 V DC, 500 mA
- Raccordement des actionneurs à 1 conducteur
- Comportement des valeurs de substitution des sorties paramétrable pour le Smart Element
- Plaque signalétique de l'appareil enregistrée
Technical Specifications
Dimensions
Width | 14.9 mm |
Height | 62.2 mm |
Depth | 62 mm |
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Smart Element interface
Number of interfaces | 1 |
Connection Method | Card edge connector |
Transmission Speed | See system in which you use the Smart Element. |
Start time until ready to operate | < 500 ms |
Module
ID code (hex) | none |
Process data channel | 16 bit |
Input address area | 0 Byte |
Output address area | 2 Byte |
Required parameter data | 9 Byte |
Required configuration data | 6 Byte |
Digital:
Output name | Digital outputs |
Connection Method | Push-in connection |
Connection technology | 1-conductor |
Number of Outputs | 16 (NPN) |
Protective circuit | Short-circuit and overload protection; electronic |
Output Voltage | 24 V |
Limitation of the voltage induced on circuit interruption | 30 V DC ... 55 V DC |
Maximum Output Current per module | 6 A (Also make sure that the maximum permissible current of 6 A is not exceeded.) |
Nominal Output Voltage | 24 V DC |
Load min. | 10 kΩ |
Output voltage when switched off | min. 23 V (At UP = 24 V DC) |
Output current when switched off | max. 100 µA |
Nominal load, inductive | 12 VA (1.2 H, 48 Ω, with nominal voltage) |
Nominal load, lamp | 12 W (at nominal voltage) |
Nominal load, ohmic | 12 W (48 Ω, with nominal voltage) |
Switching frequency | max. 1200 per second (With resistive load, at least 50 mA load current) |
Switching frequency | max. 1 per second (with inductive load) |
Switching frequency | max. 16 per second (with nominal lamp load) |
Reverse voltage resistance to short pulses | limited protection up to 0.5 A for 1 s |
Behavior with overload | Shutdown with automatic restart |
Behavior with inductive overload | Output can be destroyed |
Signal delay | max. 100 µs (when switched on) |
Signal delay | max. 100 µs (when switched off, with at least 50 mA load current) |
Overcurrent shut-down | min. 0.7 A |
Product properties
Product family | Axioline Smart Elements |
Type | modular |
Mounting Position | See the system in which the Smart Element is used. |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Electrical properties
Maximum power dissipation for nominal condition | 1.85 W |
Potentials: Communications power supply of the Smart Elements (USE)
Supply Voltage | using card edge connectors |
Potentials: I/O supply (UP)
Supply Voltage | 24 V DC (using card edge connectors) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 6 A |
Current consumption | min. 14 mA (without connected peripherals) |
Power consumption | max. 180 W (of which 1.2 W internal losses) |
Power consumption | min. 336 mW |
Protective circuit | Surge protection; See the system in which the Smart Element is used. |
Protective circuit | Reverse polarity protection; parallel diode |
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Communications supply / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | I/O |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual. |
Note on the connection method | With a small conductor cross section and high current, the terminal point temperature can reach up to 31 K above the ambient temperature. |
Note on the connection method | When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 8 mm |
I/O
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual. |
Note on the connection method | With a small conductor cross section and high current, the terminal point temperature can reach up to 31 K above the ambient temperature. |
Note on the connection method | When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL. |
Conductor cross section, rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | Smart Element slot |
Mounting Position | See the system in which the Smart Element is used. |
Why Proax for Phoenix Contact 1105560?
Proax is an authorized distributor of Phoenix Contact 1105560 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1079231 - Axioline Smart Elements, Digital output module, Functional safety, PROFIsafe, only for connection to Phoenix Contact or Siemens controller, Safe digital outputs: 2 (2-channel assignment), 4 (1-channel assignment), 24 V DC, 2 A, connection technology: 2-conductor, degree of protection: IP20