Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
AXL SE DO16/1
Series AXL-SE-DO

AXL SE DO16/1 - Digital module

Axioline Smart Elements, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 1-conductor, degree of protection: IP20

  • 16 digital outputs
  • 24 V DC, 500 mA
  • Connection of actuators in 1-conductor technology
  • Substitute value behavior of the outputs can be parameterized for the Smart Element
  • Device rating plate stored
Technical Specifications

Dimensions

Width14.9 mm
Height62.2 mm
Depth62 mm

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Smart Element interface

Number of interfaces1
Connection MethodCard edge connector
Transmission SpeedSee system in which you use the Smart Element.
Start time until ready to operate< 500 ms

Module

ID code (hex)none
Process data channel16 bit
Input address area0 Byte
Output address area2 Byte
Required parameter data 9 Byte
Required configuration data 6 Byte

Digital:

Output nameDigital outputs
Connection MethodPush-in connection
Connection technology1-conductor
Number of Outputs16
Protective circuitShort-circuit and overload protection; electronic
Output Voltage24 V
Limitation of the voltage induced on circuit interruption-32.8 V DC ... -15 V DC
Maximum Output Current per module6 A (Also make sure that the maximum permissible current of 6 A is not exceeded.)
Nominal Output Voltage24 V DC
Load min.10 kΩ
Output voltage when switched offmax. 1 V
Output current when switched offmax. 300 µA
Nominal load, inductive12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp12 W (at nominal voltage)
Nominal load, ohmic12 W (48 Ω, with nominal voltage)
Switching frequencymax. 1200 per second (With resistive load, at least 50 mA load current)
Switching frequencymax. 1 per second (with inductive load)
Switching frequencymax. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulseslimited protection up to 0.5 A for 1 s
Behavior with overloadShutdown with automatic restart
Behavior with inductive overloadOutput can be destroyed
Signal delaymax. 100 µs (when switched on)
Signal delaymax. 100 µs (when switched off, with at least 50 mA load current)
Overcurrent shut-downmin. 0.7 A
Output current with ground connection interrupt when switched off< 1 mA

Product properties

Product familyAxioline Smart Elements
Typemodular
Mounting PositionSee the system in which the Smart Element is used.

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.2 W

Potentials: Communications power supply of the Smart Elements (USE)

Supply Voltageusing card edge connectors

Potentials: I/O supply (UP)

Supply Voltage24 V DC (using card edge connectors)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 6 A
Current consumptionmin. 40 mA (without connected peripherals)
Power consumptionmax. 180 W (of which 1.1 W internal losses)
Power consumptionmin. 288 mW
Protective circuitSurge protection; See the system in which the Smart Element is used.
Protective circuitReverse polarity protection; parallel diode

Electrical isolation/isolation of the voltage ranges

Test voltage: Communications supply / 24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameI/O
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Note on the connection methodWith a small conductor cross section and high current, the terminal point temperature can reach up to 45 K above the ambient temperature.
Note on the connection methodWhen selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.25 mm² ... 1.5 mm²
Conductor cross section flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

I/O

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Note on the connection methodWith a small conductor cross section and high current, the terminal point temperature can reach up to 45 K above the ambient temperature.
Note on the connection methodWhen selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor cross section, rigid0.25 mm² ... 1.5 mm²
Conductor cross section, flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeSmart Element slot
Mounting PositionSee the system in which the Smart Element is used.
Accessories

Why Proax for Phoenix Contact 1088129?

Proax is an authorized distributor of Phoenix Contact 1088129 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability