Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1088132
Weight
0.04 kg

AXL SE IOL4 - Communication module

Axioline Smart Elements, IO-Link master, IO-Link ports Class A: 4, connection method: Push-in connection, connection technology: 3-conductor, degree of protection: IP20

  • Connection of 4 IO-Link devices
  • Alternatively: connection of one digital sensor or actuator per port
  • Connection of IO-Link devices in 3-conductor technology
  • Connection of sensors in 3-conductor technology
  • Connection of actuators in 2- and 3-conductor technology
  • Parameter data storage on the master
  • IO-Link specification V1.1.2
  • Substitute value behavior of inputs and outputs can be parameterized for each port
  • IOL-CONF supported
  • Device rating plate stored
Technical Specifications

Dimensions

Width14.9 mm
Height62.2 mm
Depth62 mm

Smart Element interface

Number of interfaces1
Connection MethodCard edge connector
Transmission SpeedSee system in which you use the Smart Element.
Start time until ready to operate< 500 ms

Module

ID code (hex)none
Process data channel512 bit
Input address area64 Byte
Output address area64 Byte

Digital

Description of the inputIO-Link ports in digital input (DI) mode
Number of Inputsmax. 4 (EN 61131-2 type 1)
Connection MethodPush-in connection
Connection technology3-conductor
Nominal input voltage UIN24 V DC
Input voltage range "0" signal-0.3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input currenttyp. 2.5 mA
Sensor current per channelmax. 500 mA (from L+/L-)
Input filter time1 µs

IO-Link

Number of Ports4
Connection MethodPush-in connection
Connection technology3-conductor
Port TypeClass A

Digital

Output descriptionIO-Link ports in digital output (DO) mode
Connection MethodPush-in connection
Connection technology2-, 3-conductor
Number of Outputsmax. 4
Nominal Output Voltage24 V DC
Nominal current per channel200 mA

Product properties

Product familyAxioline Smart Elements
Typemodular
Mounting PositionSee the system in which the Smart Element is used.

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.85 W

Supply: IO-Link

Nominal voltage for I/O supply24 V DC
Supply Voltage Range18 V DC ... 30 V DC (including all tolerances, including ripple)
Nominal current for every IO-Link port500 mA (at L+/L-)
Nominal current for every IO-Link port200 mA (at C/Q)
Protective circuitOverload protection for L+; electronically limited to 0.6 A
Protective circuitShort-circuit protection for L+; by switching off after 55 ms

Potentials: Communications power supply of the Smart Elements (USE)

Supply Voltageusing card edge connectors

Potentials: I/O supply (UP) incl. IO-Link port supply

Supply Voltage24 V DC (using card edge connectors)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 2030 mA (Internal current consumption + full load of the 4 IO-Link ports (4 x 500 mA))
Current drawtyp. 2020 mA
Current consumptionmin. 18 mA (without connected peripherals)
Power consumptionmax. 61 W (of which 1.45 W internal losses)
Power consumptionmin. 432 mW
Protective circuitSurge protection; See the system in which the Smart Element is used.
Protective circuitReverse polarity protection; Polarity protection diode

Electrical isolation/isolation of the voltage ranges

Test voltage: Communications supply / 24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameI/O
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.25 mm² ... 1.5 mm²
Conductor cross section flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

I/O

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Conductor cross section, rigid0.25 mm² ... 1.5 mm²
Conductor cross section, flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeSmart Element slot
Mounting PositionSee the system in which the Smart Element is used.
Accessories

Why Proax for Phoenix Contact AXL SE IOL4?

Proax is an authorized distributor of Phoenix Contact AXL SE IOL4 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAXLSEIOL4
Pack Size1
Recommended

Available for order