Official Distributor
SKU
MPN
AXL SE SSDO4/2 2A
Weight
0.048 kg
This product is Not Cancellable/Not Returnable
AXL SE SSDO4/2 2A - Safety module
Axioline Smart Elements, Digital output module, Functional safety, SafetyBridge technology, Safe digital outputs: 2 (2-channel assignment), 4 (1-channel assignment), 24 V DC, 2 A, connection technology: 2-conductor, degree of protection: IP20
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- 4 safe outputs for 1-channel assignment
- 2 safe outputs for 2-channel assignment
Technical Specifications
Dimensions
Width | 14.9 mm |
Height | 62.2 mm |
Depth | 62 mm |
Smart Element interface
Number of interfaces | 1 |
Connection Method | Card edge connector |
Transmission Speed | See system in which you use the Smart Element. |
Module
Input address area | 5 Byte |
Output address area | 6 Byte |
Digital:
Output name | Safe digital outputs |
Output description | EN 61131-2 |
Connection Method | Push-in connection |
Connection technology | 2-conductor |
Number of Outputs | 2 (2-channel assignment) |
Number of Outputs | 4 (1-channel assignment) |
Protective circuit | Short-circuit protection, overload protection of the outputs; electronic |
Output Voltage | 24 V DC |
Output Current | max. 2 A (per output) |
Maximum Output Current per channel | 2 A |
Maximum Output Current per module | 4 A |
Nominal Output Voltage | 24 V DC |
Load min. | 1.5 kΩ (at nominal voltage) |
Output voltage when switched off | < 5 V |
Output current when switched off | < 2 mA |
Nominal load, inductive | 48 VA (1 H; 12 Ω; at nominal voltage) |
Nominal load, ohmic | 48 W (12 Ω, at nominal voltage) |
Switching frequency | 1 Hz (0.2 Hz at > 1 A) |
Reverse voltage resistance to short pulses | no |
Behavior with overload | Switch-off of the relevant output, restart upon acknowledgment |
Behavior with inductive overload | Output can be destroyed |
Product properties
Product family | Axioline Smart Elements |
Application | Functional safety |
Application | SafetyBridge technology |
Type | modular |
Mounting Position | any |
Operating mode | SafetyBridge |
Insulation characteristics
Overvoltage category | II (IEC 60664-1) |
Pollution degree | 2 (EN 60664-1) |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Current draw | max. 120 mA (at UBus 5 V DC) |
Current draw | typ. 93 mA (at UBus 5 V DC) |
Potentials: Communications power supply of the Smart Elements (USE)
Supply Voltage | using card edge connectors |
Potentials: I/O supply (UP)
Supply Voltage | 24 V DC (using card edge connectors) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 30 mA ((Supply from UP with 30 V DC, all outputs set, without supply to the actuators)) |
Current draw | typ. 25 mA ((Supply from UP with 24 V DC, all outputs set, without supply to the actuators)) |
Current consumption | min. 21 mA ((Supply from UP with 19.2 V DC, all outputs set, without supply to the actuators)) |
Power consumption | max. 900 mW |
Power consumption | min. 403 mW |
Connection technology
Connection name | I/O |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
I/O
Connection Method | Push-in connection |
Note on the connection method | Note the specification in the section Conductor cross sections, and stripping and insertion lengths. |
Conductor cross section, rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Degree of protection at installation location | min. IP54 |
Air pressure (operation) | 70 kPa ... 108 kPa |
Air pressure (storage/transport) | 66 kPa ... 108 kPa |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Air clearances and creepage distances
Air clearances and creepage distances | IEC 60664-1 |
Mounting
Mounting Type | Smart Element slot |
Mounting Position | any |
Accessories
- 1031721 - Crimping pliers, contact connection type: Insulated and uninsulated ferrules, standards/specifications: DIN 46228-1, DIN 46228-4, UL 486F, form A, E, F, min. cross section: 0.14 mm2, max. cross section: 10 mm2, for TWIN ferrules up to 2 x 4 mm2, automatic cross section adjustment, rotating die, lateral and frontal insertion, compression: Trapezoidal crimp, black/green
- 1134913 - Crimping pliers, contact connection type: Insulated and uninsulated ferrules, standards/specifications: DIN 46228-1, DIN 46228-4, min. cross section: 0.14 mm2, max. cross section: 10 mm2, For TWIN ferrules up to 2 x 4 mm2, automatic cross section adjustment, frontal insertion, compression: Trapezoidal crimp, black
Why Proax for Phoenix Contact 1190017?
Proax is an authorized distributor of Phoenix Contact 1190017 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- Axioline Smart Elements, Module de détermination de la température, Entrées analogiques: 4 (Entrées pour thermocouples ou tension linéaire), connectique: à 2 fils (blindés, torsadés par paires), Point de comparaison externe (également utilisable comme entrée supplémentaire du capteur Pt 100): 1, connectique: 4 fils, indice de protection: IP20
- 1079231 - Axioline Smart Elements, Digital output module, Functional safety, PROFIsafe, only for connection to Phoenix Contact or Siemens controller, Safe digital outputs: 2 (2-channel assignment), 4 (1-channel assignment), 24 V DC, 2 A, connection technology: 2-conductor, degree of protection: IP20