Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MINI MCR-2-UNI-UI-2UI
Weight
0.126 kg
Series MINI-MCR

MINI MCR-2-UNI-UI-2UI - Signal duplicator

Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Screw connection technology, standard configuration.

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog Pro
No. of channels2
TypeSignal conditioner
ConfigurationDIP switches
ConfigurationSoftware
ConfigurationApp

Insulation characteristics: GB Standard

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches
ConfigurationSoftware
ConfigurationApp

Electrical properties

Electrical isolation4-way isolation
Step response (0–99%)140 ms (15 Hz sample rate)
Step response (0–99%)45 ms (60 Hz sample rate)
Step response (0–99%)25 ms (240 Hz sample rate, can only be set via software)
Maximum temperature coefficient0.01 %/K
Maximum transmission error0.05 % (of final value)

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage3 kV AC (50 Hz, 60 s)
InsulationReinforced insulation according to IEC/EN 61010-1

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption55 mA (24 V DC)
Typical current consumption110 mA (12 V DC)
Power consumption1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Signal: Voltage/current

Number of Inputs1
Configurable/programmableYes
Voltage input signal0 V ... 10 V (via DIP switch)
Voltage input signal2 V ... 10 V (via DIP switch)
Voltage input signal0 V ... 5 V (via DIP switch)
Voltage input signal1 V ... 5 V (via DIP switch)
Voltage input signal0 V ... 12 V (can be set via software)
Max. voltage input signal12 V
Current Input Signal0 mA ... 20 mA (via DIP switch)
Current Input Signal4 mA ... 20 mA (via DIP switch)
Current Input Signal0 mA ... 10 mA (via DIP switch)
Current Input Signal20 mA ... 0 mA (via DIP switch)
Current Input Signal0 mA ... 24 mA (can be set via software)
Max. current input signal24 mA
Input resistance of voltage input> 120 kΩ
Input resistance current input~ 50 Ω (+0.7 V for test diode)
Number of Outputs2
Voltage output signal0 V ... 10 V (via DIP switch)
Voltage output signal2 V ... 10 V (via DIP switch)
Voltage output signal0 V ... 5 V (via DIP switch)
Voltage output signal1 V ... 5 V (via DIP switch)
Voltage output signal0 V ... 10.5 V (can be set via software)
Max. voltage output signal~ 12.3 V
Non-load voltage≤ 18.5 V
Current Output Signal0 mA ... 20 mA (via DIP switch)
Current Output Signal4 mA ... 20 mA (via DIP switch)
Current Output Signal0 mA ... 10 mA (via DIP switch)
Current Output Signal20 mA ... 0 mA (via DIP switch)
Current Output Signal0 mA ... 21 mA (can be set via software)
Max. current output signal24.6 mA
Short-circuit current≤ 25 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output≤ 600 Ω (per channel)
Ripple< 20 mVPP (600 Ω)
Ripple< 20 mVPP (600 Ω)

Connection data

Connection MethodScrew connection
Stripping length10 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 1.5 mm² (with ferrule)
Conductor cross section rigid0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Data: IFS interface

Connection MethodMicro USB type B

Signaling

Status displayGreen LED (supply voltage)
Error indicationRed LED

Dimensions

Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material specifications

Colorgray (RAL 7042)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateBVS 19 ATEX E 083 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIF21UKEX2905026X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx BVS 19.0072X

CCC / China-Ex

IdentificationEx nA IIC T4 Gc
CertificateNEPSI GYJ20.1318X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T6
IdentificationClass I, Zone 2, Group IIC T6

Shipbuilding approval

CertificateDNV GL TAA000021E Rev. 1

EAC Ex

Identification 2Ex ec IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00081

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.2 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value0.1 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2.8 %

Standards and Regulations

Electrical isolation4-way isolation

GB Standard

Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.8

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2905026?

Proax is an authorized distributor of Phoenix Contact 2905026 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability