Official Distributor
SKU
MPN
MINI MCR-2-UI-UI-PT
Weight
0.116 kg
Series MINI-MCR
MINI MCR-2-UI-UI-PT - Signal conditioner
3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover, for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. push-in connection technology, standard configuration.
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog Pro |
No. of channels | 1 |
Type | Signal conditioner |
Configuration | DIP switches |
Insulation characteristics: GB Standard
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Electrical isolation | 3-way isolation |
Electrical isolation between input and output | yes |
Limit frequency (3 dB) | 30 Hz (via DIP switch) |
Limit frequency (3 dB) | 5 kHz (via DIP switch) |
Protective circuit | Transient protection |
Step response (10-90%) | < 12 ms (with 30 Hz filter) |
Maximum temperature coefficient | 0.01 %/K |
Temperature coefficient, typical | 0.01 %/K |
Maximum transmission error | ≤ 0.1 % (of final value) |
Maximum transmission error | ≤ 0.15 % (of final value, at IN: 4 mA ... 20 mA / OUT: -10 V ... 10 V) |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 300 Vrms |
Test voltage | 3 kV AC (50 Hz, 60 s) |
Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Typical current consumption | 25 mA (Current output, at 24 V DC incl. load) |
Typical current consumption | 54 mA (Current output, at 12 V DC incl. load) |
Power consumption | ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) |
Signal: Voltage/current
Number of Inputs | 1 |
Configurable/programmable | Yes |
Voltage input signal | 0 V ... 5 V (via DIP switch) |
Voltage input signal | 1 V ... 5 V (via DIP switch) |
Voltage input signal | -5 V ... 5 V (via DIP switch) |
Voltage input signal | 0 V ... 10 V (via DIP switch) |
Voltage input signal | 2 V ... 10 V (via DIP switch) |
Voltage input signal | -10 V ... 10 V (via DIP switch) |
Voltage input signal | 0 V ... 20 V (via DIP switch) |
Voltage input signal | 4 V ... 20 V (via DIP switch) |
Voltage input signal | -20 V ... 20 V (via DIP switch) |
Voltage input signal | 0 V ... 24 V (via DIP switch) |
Voltage input signal | 4.8 V ... 24 V (via DIP switch) |
Voltage input signal | -24 V ... 24 V (via DIP switch) |
Voltage input signal | 0 V ... 30 V (via DIP switch) |
Voltage input signal | 6 V ... 30 V (via DIP switch) |
Voltage input signal | -30 V ... 30 V (via DIP switch) |
Max. voltage input signal | 33 V |
Current Input Signal | 0 mA ... 20 mA (via DIP switch) |
Current Input Signal | 4 mA ... 20 mA (via DIP switch) |
Current Input Signal | -20 mA ... 20 mA (via DIP switch) |
Max. current input signal | 24 mA |
Input resistance of voltage input | > 1000 kΩ |
Input resistance current input | approx. 63 Ω (+0.7 V for test diode) |
Number of Outputs | 1 |
Configurable/programmable | Yes |
Voltage output signal | 0 V ... 5 V (via DIP switch) |
Voltage output signal | 1 V ... 5 V (via DIP switch) |
Voltage output signal | -5 V ... 5 V (via DIP switch) |
Voltage output signal | 0 V ... 10 V (via DIP switch) |
Voltage output signal | 2 V ... 10 V (via DIP switch) |
Voltage output signal | -10 V ... 10 V (via DIP switch) |
Non-load voltage | < 17 V |
Current Output Signal | 0 mA ... 20 mA (via DIP switch) |
Current Output Signal | 4 mA ... 20 mA (via DIP switch) |
Max. current output signal | 22 mA |
Short-circuit current | < 32 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/Output Load Current Output | ≤ 600 Ω (at 20 mA) |
Ripple | < 20 mVPP (at 600 Ω) |
Ripple | < 20 mVPP (at 600 Ω) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 (flexible) |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Signaling
Status display | Green LED (supply voltage) |
Dimensions
Width | 6.2 mm |
Height | 109.81 mm |
Depth | 119.2 mm |
Material specifications
Color | gray (RAL 7042) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex ec ic IIC T4 Gc |
Certificate | BVS 19 ATEX E 047 X |
UKCA Ex (UKEX)
Identification | II 3 G Ex ec ic IIC T4 Gc |
Certificate | PxCIF21UKEX2902000X |
IECEx
Identification | Ex ec ic IIC T4 Gc |
Certificate | IECEx BVS 19.0041X |
CCC / China-Ex
Identification | Ex nA ic IIC T4 Gc |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T6 |
Identification | Class I, Zone 2, Group IIC T6 |
Shipbuilding approval
Certificate | DNV GL TAA00002UA |
EAC Ex
Identification | 2Ex ec ic IIC T4 Gc |
Certificate | BY/112 02.01 TP012 103.01 00079 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Standards and Regulations
Electrical isolation | 3-way isolation |
GB Standard
Standards/regulations | GB 3836.1 |
Standards/regulations | GB 3836.4 |
Standards/regulations | GB 3836.8 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902040?
Proax is an authorized distributor of Phoenix Contact 2902040 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended