SKU
MPN
MINI MCR-2-TC-UI
Weight
0.124 kg
This product is Not Cancellable/Not Returnable
Series MINI-MCR

MINI MCR-2-TC-UI - Thermocouple measuring transducer

Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, standard configuration

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog Pro
TypeSignal conditioner
ConfigurationDIP switches
ConfigurationSoftware
ConfigurationApp

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolation3-way isolation
Typical cold point errors2 K (2 K + (0.2 K * ΔT))
Protective circuitTransient protection
Step response (0–99%)300 ms
Step response (0–99%)570 ms
Maximum temperature coefficient≤ 0.01 %/K
Transmission error thermocouples0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
Transmission error thermocouples0.2 % * 600 K / set measuring range; 0.2 % > 600 K (B, R, S, A1, A2, A3)
Transmission error thermocouples0.2% * 600 K / set measuring range; 0.2% > 600 K (E, J, K, N, T, L, U, M Gost, L Gost); Highspeed Mode
Transmission error thermocouples0.4% * 600 K / set measuring range; 0.4% > 600 K (B, R, S, A1, A2, A3); Highspeed Mode

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage3 kV AC (50 Hz, 60 s)
InsulationReinforced insulation according to IEC/EN 61010-1

Supply

Supply Voltage Range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption32.7 mA (24 V DC)
Typical current consumption66.8 mA (12 V DC)
Power consumption≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Signal

Number of Inputs1

Measurement

Number of Inputs1
Configurable/programmableYes
Input voltage range- 500 mV ... 500 mV (can be set via software)
Sensor types that can be used (TC)B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
Temperature measuring range≥ 50 K
Voltage measuring range3 mV
Sensor type: 500 °C ... 1820 °C
Sensor type: -230 °C ... 1000 °C
Sensor type: -210 °C ... 1200 °C
Sensor type: -250 °C ... 1372 °C
Sensor type: -200 °C ... 1300 °C
Sensor type: -50 °C ... 1768 °C
Sensor type: -50 °C ... 1768 °C
Sensor type: -200 °C ... 400 °C
Sensor type: -200 °C ... 900 °C
Sensor type: -200 °C ... 600 °C
Sensor type: 0 °C ... 2500 °C
Sensor type: 0 °C ... 1800 °C
Sensor type: 0 °C ... 1800 °C
Sensor type: -200 °C ... 100 °C
Sensor type: -200 °C ... 800 °C

Signal: Voltage/current

Number of Outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V (via DIP switch)
Voltage output signal1 V ... 5 V (via DIP switch)
Voltage output signal0 V ... 10 V (via DIP switch)
Voltage output signal10 V ... 0 V (via DIP switch)
Voltage output signal0 V ... 10.5 V (can be set via software)
Max. voltage output signal 12.3 V
Non-load voltage< 17.5 V
Current Output Signal0 mA ... 20 mA (via DIP switch)
Current Output Signal4 mA ... 20 mA (via DIP switch)
Current Output Signal20 mA ... 0 mA (via DIP switch)
Current Output Signal20 mA ... 4 mA (via DIP switch)
Current Output Signal0 mA ... 21 mA (can be set via software)
Max. current output signal24.6 mA
Short-circuit current< 31.5 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output≤ 600 Ω (20 mA)
Ripple< 10 mVrms
Ripple< 10 mVrms (600 Ω)
Resolution, outputs (voltage)1 mV
Resolution, outputs (current)2 µA

Connection data

Connection MethodScrew connection
Stripping length10 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 1.5 mm² (with ferrule)
Conductor cross section rigid0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Data: IFS interface

Connection MethodMicro USB type B

Signaling

Status displayGreen LED (supply voltage)
Error indicationRed LED

Dimensions

Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material specifications

Colorgray (RAL 7042)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateBVS 20 ATEX E 024 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIF21UKEX2902049X

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx BVS 20.0017X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T6
IdentificationClass I, Zone 2, Group IIC T6

Shipbuilding approval

CertificateDNV GL TAA00002UA

EAC Ex

Identification 2Ex ec IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00079

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.06 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value0.1 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value0.05 %

Standards and Regulations

Electrical isolation3-way isolation

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2902055?

Proax is an authorized distributor of Phoenix Contact 2902055 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability