Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog Pro |
No. of channels | 1 |
Type | Signal conditioner |
Configuration | DIP switches |
Insulation characteristics: GB Standard
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Electrical isolation | 2-way isolation |
Electrical isolation between input and output | yes |
Limit frequency (3 dB) | approx. 30 Hz |
Step response (10-90%) | 20 ms |
Maximum temperature coefficient | 0.01 %/K |
Temperature coefficient, typical | 0.005 %/K |
Maximum transmission error | ≤ 0.1 % (of final value) |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 300 Vrms |
Test voltage | 3 kV AC (50 Hz, 60 s) |
Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
Supply Voltage Range | 8 V DC ... 30 V DC (loop-powered, no external supply necessary) |
Typical current consumption | ≤ 20 mA |
Power consumption | ≤ 600 mW |
Signal: Voltage/current
Number of Inputs | 1 |
Configurable/programmable | Yes |
Voltage input signal | 0 mV ... 1000 mV |
Voltage input signal | 0 mV ... 750 mV |
Voltage input signal | 0 mV ... 500 mV |
Voltage input signal | 0 mV ... 300 mV |
Voltage input signal | 0 mV ... 250 mV |
Voltage input signal | 0 mV ... 200 mV |
Voltage input signal | 0 mV ... 125 mV |
Voltage input signal | 0 mV ... 120 mV |
Voltage input signal | 0 mV ... 150 mV |
Voltage input signal | 0 mV ... 100 mV |
Voltage input signal | 0 mV ... 75 mV |
Voltage input signal | 0 mV ... 60 mV |
Voltage input signal | 0 mV ... 50 mV |
Voltage input signal | 0 V ... 10 V |
Voltage input signal | 0 V ... 7.5 V |
Voltage input signal | 0 V ... 5 V |
Voltage input signal | 0 V ... 3 V |
Voltage input signal | 0 V ... 2.5 V |
Voltage input signal | 0 V ... 2 V |
Voltage input signal | 0 V ... 1.5 V |
Voltage input signal | 0 V ... 1.25 V |
Voltage input signal | 0 V ... 1.2 V |
Voltage input signal | 0 V ... 30 V |
Voltage input signal | 0 V ... 25 V |
Voltage input signal | 0 V ... 20 V |
Voltage input signal | 0 V ... 12.5 V |
Voltage input signal | 0 V ... 12 V |
Voltage input signal | 0 V ... 15 V |
Voltage input signal | -1000 mV ... 1000 mV |
Voltage input signal | -750 mV ... 750 mV |
Voltage input signal | -500 mV ... 500 mV |
Voltage input signal | -300 mV ... 300 mV |
Voltage input signal | -250 mV ... 250 mV |
Voltage input signal | -200 mV ... 200 mV |
Voltage input signal | -125 mV ... 125 mV |
Voltage input signal | -120 mV ... 120 mV |
Voltage input signal | -150 mV ... 150 mV |
Voltage input signal | -100 mV ... 100 mV |
Voltage input signal | -75 mV ... 75 mV |
Voltage input signal | -60 mV ... 60 mV |
Voltage input signal | -50 mV ... 50 mV |
Voltage input signal | -10 V ... 10 V |
Voltage input signal | -7.5 V ... 7.5 V |
Voltage input signal | -5 V ... 5 V |
Voltage input signal | -3 V ... 3 V |
Voltage input signal | -2.5 V ... 2.5 V |
Voltage input signal | -2 V ... 2 V |
Voltage input signal | -1.25 V ... 1.25 V |
Voltage input signal | -1.2 V ... 1.2 V |
Voltage input signal | -1.5 V ... 1.5 V |
Voltage input signal | -30 V ... 30 V |
Voltage input signal | -25 V ... 25 V |
Voltage input signal | -20 V ... 20 V |
Voltage input signal | -12.5 V ... 12.5 V |
Voltage input signal | -12 V ... 12 V |
Voltage input signal | -15 V ... 15 V |
Voltage input signal | 2 V ... 10 V (additional areas can be configured, see table) |
Voltage input signal | 1 V ... 5 V (additional areas can be configured, see table) |
Max. voltage input signal | < 30 V |
Current Input Signal | 0 mA ... 40 mA |
Current Input Signal | 0 mA ... 30 mA |
Current Input Signal | 0 mA ... 20 mA |
Current Input Signal | 0 mA ... 12 mA |
Current Input Signal | 0 mA ... 10 mA |
Current Input Signal | 0 mA ... 8 mA |
Current Input Signal | 0 mA ... 7.5 mA |
Current Input Signal | 0 mA ... 6 mA |
Current Input Signal | 0 mA ... 5 mA |
Current Input Signal | 0 mA ... 4 mA |
Current Input Signal | 0 mA ... 3 mA |
Current Input Signal | 0 mA ... 2.5 mA |
Current Input Signal | 0 mA ... 2 mA |
Current Input Signal | 4 mA ... 20 mA |
Current Input Signal | 2 mA ... 10 mA |
Current Input Signal | 1 mA ... 5 mA |
Max. current input signal | 50 mA (Dielectric strength up to 30 V) |
Input resistance of voltage input | 100 kΩ (≤ 1 V) |
Input resistance of voltage input | 1 MΩ (≥ 1 V) |
Input resistance current input | 25 Ω (+0.7 V for test diode) |
Signal: Current
Number of Outputs | 1 |
Current Output Signal | 4 mA ... 20 mA |
Max. current output signal | 32 mA |
Load/Output Load Current Output | < 1000 Ω ((UB - 8 V) / 22 mA) |
Ripple | < 10 mVrms (at 600 Ω) |
Connection data
Connection Method | Screw connection |
Stripping length | 10 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² (with ferrule) |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 (flexible) |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Signaling
Status display | Green LED (supply voltage) |
Dimensions
Width | 6.2 mm |
Height | 109.81 mm |
Depth | 119.2 mm |
Material specifications
Color | gray (RAL 7042) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | BVS 19 ATEX E 079 X |
UKCA Ex (UKEX)
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | PxCIF21UKEX2901994X |
IECEx
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx BVS 19.0068X |
CCC / China-Ex
Identification | Ex nA IIC T4 Gc |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T5 |
Identification | Class I, Zone 2, Group IIC T5 |
Shipbuilding approval
Certificate | DNV GL TAA000021E Rev. 1 |
EAC Ex
Identification | 2Ex ec IIC T4 Gc |
Certificate | BY/112 02.01 TP012 103.01 00081 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Standards and Regulations
Electrical isolation | 2-way isolation |
GB Standard
Standards/regulations | GB 3836.1 |
Standards/regulations | GB 3836.8 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902061?
Proax is an authorized distributor of Phoenix Contact 2902061 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended