Series MINI-MCR

MINI MCR-2-UI-UI - Signal conditioner

3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, standard configuration.

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog Pro
No. of channels1
TypeSignal conditioner
ConfigurationDIP switches

Insulation characteristics: GB Standard

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolation3-way isolation
Electrical isolation between input and outputyes
Limit frequency (3 dB)30 Hz (via DIP switch)
Limit frequency (3 dB)5 kHz (via DIP switch)
Protective circuitTransient protection
Step response (10-90%)< 12 ms (with 30 Hz filter)
Maximum temperature coefficient0.01 %/K
Temperature coefficient, typical0.01 %/K
Maximum transmission error≤ 0.1 % (of final value)
Maximum transmission error≤ 0.15 % (of final value, at IN: 4 mA ... 20 mA / OUT: -10 V ... 10 V)

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage3 kV AC (50 Hz, 60 s)
InsulationReinforced insulation according to IEC/EN 61010-1

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption25 mA (Current output, at 24 V DC incl. load)
Typical current consumption54 mA (Current output, at 12 V DC incl. load)
Power consumption≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Signal: Voltage/current

Number of Inputs1
Configurable/programmableYes
Voltage input signal0 V ... 5 V (via DIP switch)
Voltage input signal1 V ... 5 V (via DIP switch)
Voltage input signal-5 V ... 5 V (via DIP switch)
Voltage input signal0 V ... 10 V (via DIP switch)
Voltage input signal2 V ... 10 V (via DIP switch)
Voltage input signal-10 V ... 10 V (via DIP switch)
Voltage input signal0 V ... 20 V (via DIP switch)
Voltage input signal4 V ... 20 V (via DIP switch)
Voltage input signal-20 V ... 20 V (via DIP switch)
Voltage input signal0 V ... 24 V (via DIP switch)
Voltage input signal4.8 V ... 24 V (via DIP switch)
Voltage input signal-24 V ... 24 V (via DIP switch)
Voltage input signal0 V ... 30 V (via DIP switch)
Voltage input signal6 V ... 30 V (via DIP switch)
Voltage input signal-30 V ... 30 V (via DIP switch)
Max. voltage input signal33 V
Current Input Signal0 mA ... 20 mA (via DIP switch)
Current Input Signal4 mA ... 20 mA (via DIP switch)
Current Input Signal-20 mA ... 20 mA (via DIP switch)
Max. current input signal24 mA
Input resistance of voltage input> 1000 kΩ
Input resistance current inputapprox. 63 Ω (+0.7 V for test diode)
Number of Outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V (via DIP switch)
Voltage output signal1 V ... 5 V (via DIP switch)
Voltage output signal-5 V ... 5 V (via DIP switch)
Voltage output signal0 V ... 10 V (via DIP switch)
Voltage output signal2 V ... 10 V (via DIP switch)
Voltage output signal-10 V ... 10 V (via DIP switch)
Non-load voltage< 17 V
Current Output Signal0 mA ... 20 mA (via DIP switch)
Current Output Signal4 mA ... 20 mA (via DIP switch)
Max. current output signal22 mA
Short-circuit current< 32 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output≤ 600 Ω (at 20 mA)
Ripple< 20 mVPP (at 600 Ω)
Ripple< 20 mVPP (at 600 Ω)

Connection data

Connection MethodScrew connection
Stripping length10 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 1.5 mm² (with ferrule)
Conductor cross section rigid0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Signaling

Status displayGreen LED (supply voltage)

Dimensions

Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material specifications

Colorgray (RAL 7042)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec ic IIC T4 Gc
CertificateBVS 19 ATEX E 047 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec ic IIC T4 Gc
CertificatePxCIF21UKEX2902000X

IECEx

IdentificationEx ec ic IIC T4 Gc
CertificateIECEx BVS 19.0041X

CCC / China-Ex

IdentificationEx nA ic IIC T4 Gc

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T6
IdentificationClass I, Zone 2, Group IIC T6

Shipbuilding approval

CertificateDNV GL TAA00002UA

EAC Ex

Identification 2Ex ec ic IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00079

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4

Surge current load (surge)

Standards/regulationsEN 61000-4-5

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6

Standards and Regulations

Electrical isolation3-way isolation

GB Standard

Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.4
Standards/regulationsGB 3836.8

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2902037?

Proax is an authorized distributor of Phoenix Contact 2902037 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability