Official Distributor
SKU
MPN
MINI MCR-2-UI-REL-PT
Weight
0.122 kg
Series MINI-MCR
MINI MCR-2-UI-REL-PT - Limit value switch
Universally configurable threshold value switch with changeover contact relay output and plug-in connection technology for switching analog limit values. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog Pro |
No. of channels | 1 |
Type | Signal conditioner |
Configuration | DIP switches |
Configuration | Software |
Configuration | App |
Insulation characteristics: GB Standard
Overvoltage category | II |
Pollution degree | 2 |
Functionality
Configuration | DIP switches |
Configuration | Software |
Configuration | App |
Electrical properties
Electrical isolation between input and output | yes |
Switching point accuracy | < 0.1 % |
Step response (0–99%) | 140 ms (can be set via software) |
Maximum temperature coefficient | 0.01 %/K |
Maximum transmission error | 0.1 % (of final value) |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 300 Vrms |
Test voltage | 3 kV AC (50 Hz, 60 s) |
Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Typical current consumption | 40 mA (12 V DC) |
Typical current consumption | 20 mA (24 V DC) |
Power consumption | ≤ 0.5 W |
Signal: Voltage/current
Configurable/programmable | Yes |
Voltage input signal | 0 V ... 10 V (via DIP switch) |
Voltage input signal | 0 V ... 12 V (can be set via software) |
Max. voltage input signal | 12 V |
Current Input Signal | 0 mA ... 20 mA (via DIP switch) |
Current Input Signal | 0 mA ... 24 mA (can be set via software) |
Max. current input signal | 24 mA |
Input resistance of voltage input | > 120 kΩ |
Input resistance current input | 50 Ω (+0.7 V for test diode) |
Specification of the switching point | Can be set via software or in steps via DIP switches |
Switching: Relay
Contact switching type | 1 changeover contact |
Contact Material | AgSnO2, hard gold-plated |
Maximum Switching Voltage | 250 V AC |
Maximum Switching Voltage | 30 V DC |
Maximum Switching Voltage | 240 V AC (UL) |
Limiting Continuous Current | 6 A AC |
Limiting Continuous Current | 4 A DC |
Min. switching current | 100 mA (12 V DC) |
Max. switching current | 6 A AC (250 V AC) |
Max. switching current | 4 A DC (30 V DC) |
Mechanical service life | 2x 107 cycles |
Setting range of the response delay | 0 s ... 10 s (can be set freely via software) |
Internal hysteresis | can be set freely via software |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 (flexible) |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Data: IFS interface
Connection Method | Micro USB type B |
Signaling
Status display | Green LED (supply voltage) |
Status display | Yellow LED (switching output) |
Error indication | Red LED |
Dimensions
Width | 6.2 mm |
Height | 109.81 mm |
Depth | 119.2 mm |
Material specifications
Color | gray (RAL 7042) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3G Ex ec ic nC IIC T4 Gc |
Certificate | BVS 18 ATEX E 071 X |
UKCA Ex (UKEX)
Identification | II 3 G Ex ec ic IIC T4 Gc |
Certificate | PxCIF21UKEX2905632X |
IECEx
Identification | Ex ec ic nC IIC T4 Gc |
Certificate | IECEx BVS 18.0060X |
CCC / China-Ex
Identification | Ex ic nA nC IIC T4 Gc |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4A |
Identification | Class I, Zone 2, Group IIC T4A |
Shipbuilding approval
Certificate | DNV GL TAA000021E Rev. 1 |
EAC Ex
Identification | 2Ex ec ic nC IIC T4 Gc |
Certificate | BY/112 02.01 TP012 103.01 00081 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
GB Standard
Standards/regulations | GB 3836.1 |
Standards/regulations | GB 3836.4 |
Standards/regulations | GB 3836.8 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902035?
Proax is an authorized distributor of Phoenix Contact 2902035 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended