Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1182185
Weight
0.038 kg

AXL SE INC1 ASYM - Function module

Axioline Smart Elements, Position detection module, Incremental encoder input: 1, Asymmetrical encoder, Digital inputs: 2, 24 V DC, degree of protection: IP20

  • Acquisition of digital signals from asymmetrical incremental encoders (A, B, Z)
  • Acquisition of pulses of up to 300 kHz
  • Evaluating linear or rotary axes
  • Power supply for 5 V or 24 V encoder
  • 1 input can be used for referencing
  • Latch function for quick buffering of positions
  • 32-bit register to output the measured increments
  • Device rating plate stored
Technical Specifications

Dimensions

Width14.9 mm
Height62.2 mm
Depth62 mm

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Smart Element interface

Number of interfaces1
Connection MethodCard edge connector
Transmission SpeedSee system in which you use the Smart Element.
Start time until ready to operate< 500 ms

Module

ID code (hex)none
Process data channel80 bit
Input address area10 Byte
Output address area10 Byte
Required parameter data 19 Byte
Required configuration data 7 Byte

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2, type 3
Number of Inputs2 (DI Ref, DI L)
Connection MethodPush-in connection
Connection technology1-conductor
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UIN3 mA
Protective circuitTransient protection; Suppressor diode

Encoder

Number of Inputs1 (A, B, Z)
Input nameIncremental encoder input
Encoder signalsAsymmetrical encoder
Cable Length< 30 m (Shielded cable)

Product properties

Product familyAxioline Smart Elements
Typemodular
Mounting PositionSee the system in which the Smart Element is used.

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.8 W

Encoder

Number1 (+5 V)
Nominal Output Voltage5 V DC
Voltage range5 V DC ... 5.5 V DC
Current carrying capacitymax. 300 mA
Protective circuitShort-circuit protection; Electrical and thermal
Protective circuitOverload protection
Protective circuitTransient protection; Suppressor diode
Number1 (+24 V)
Nominal Output Voltage24 V DC
Voltage range19.2 V DC ... 30 V DC
Current carrying capacitymax. 500 mA
Protective circuitShort-circuit protection; Electrical (from approx. 600 mA)
Protective circuitOverload protection
Protective circuitTransient protection; Suppressor diode
Number1 (A, B, Z)
DesignationAsymmetrical incremental encoder
Input Frequencymax. 300 kHz

Potentials: Communications power supply of the Smart Elements (USE)

Supply Voltageusing card edge connectors

Potentials: I/O supply (UP)

Supply Voltage24 V DC (using card edge connectors)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 700 mA
Current drawtyp. 512 mA
Current consumptionmin. 11 mA (without connected peripherals)
Power consumptionmax. 21 W (of which 1.55 W internal losses)
Power consumptionmin. 264 mW
Protective circuitSurge protection; See the system in which the Smart Element is used.
Protective circuitReverse polarity protection; Polarity protection diode

Electrical isolation/isolation of the voltage ranges

Test voltage: Communications supply / 24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameI/O
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.25 mm² ... 1.5 mm²
Conductor cross section flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

I/O

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Conductor cross section, rigid0.25 mm² ... 1.5 mm²
Conductor cross section, flexible0.25 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeSmart Element slot
Mounting PositionSee the system in which the Smart Element is used.

Why Proax for Phoenix Contact AXL SE INC1 ASYM?

Proax is an authorized distributor of Phoenix Contact AXL SE INC1 ASYM and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information