MINI MCR-SL-SHUNT-UI-SP-NC - Signal conditioner
MCR 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range, both・unipolar・and・bipolar with spring-cage connection, not preconfigured. Replacement part: 2902021 MINI MCR-2-U-UI-PT.
- Power supply possible via the foot element (TBUS)
- Low power consumption
- Ideal for converting signals for shunt measurements
- Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of mV signals to create standard analog signals
- Up to 280 signal combinations can be configured using DIP switches
- 3-way isolation
Technical Specifications
Product properties
Product family | MINI Analog |
No. of channels | 1 |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Rated Insulation Voltage | 30 V AC |
Rated Insulation Voltage | 50 V DC |
Electrical isolation | Basic insulation in accordance with EN 61010 |
Electrical isolation between input and output | yes |
Limit frequency (3 dB) | 100 Hz / 30 Hz switchable |
Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) |
Step response (10-90%) | 3.5 ms (100 Hz) |
Maximum temperature coefficient | < 0.01 %/K |
Temperature coefficient, typical | < 0.002 %/K |
Maximum transmission error | ≤ 0.2 % |
Maximum transmission error | < 0.4 % (Without adjustment) |
Supply
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Max. current consumption | < 25 mA |
Power consumption | < 450 mW (Current output) |
Signal: Voltage
Number of Inputs | 1 |
Configurable/programmable | Yes, unconfigured |
Voltage input signal | -50 mV ... 50 mV |
Voltage input signal | -60 mV ... 60 mV |
Voltage input signal | -75 mV ... 75 mV |
Voltage input signal | -80 mV ... 80 mV |
Voltage input signal | -100 mV ... 100 mV |
Voltage input signal | -120 mV ... 120 mV |
Voltage input signal | -150 mV ... 150 mV |
Voltage input signal | -200 mV ... 200 mV |
Voltage input signal | -240 mV ... 240 mV |
Voltage input signal | -300 mV ... 300 mV |
Voltage input signal | -500 mV ... 500 mV |
Voltage input signal | -600 mV ... 600 mV |
Voltage input signal | -750 mV ... 750 mV |
Voltage input signal | -800 mV ... 800 mV |
Voltage input signal | -1 V ... 1 V |
Voltage input signal | -1.2 V ... 1.2 V |
Voltage input signal | -1.5 V ... 1.5 V |
Voltage input signal | -2 V ... 2 V |
Voltage input signal | -2.4 V ... 2.4 V |
Voltage input signal | -3 V ... 3 V |
Voltage input signal | 0 mV ... 50 mV (additional areas can be configured, see table) |
Voltage input signal | 0 mV ... 60 mV |
Voltage input signal | 0 mV ... 75 mV |
Voltage input signal | 0 mV ... 80 mV |
Voltage input signal | 0 mV ... 100 mV |
Voltage input signal | 0 mV ... 120 mV |
Voltage input signal | 0 mV ... 150 mV |
Voltage input signal | 0 mV ... 200 mV |
Voltage input signal | 0 mV ... 240 mV |
Voltage input signal | 0 mV ... 300 mV |
Voltage input signal | 0 mV ... 500 mV |
Voltage input signal | 0 mV ... 600 mV |
Voltage input signal | 0 mV ... 750 mV |
Voltage input signal | 0 mV ... 800 mV |
Voltage input signal | 0 V ... 1 V |
Voltage input signal | 0 V ... 1.2 V |
Voltage input signal | 0 V ... 1.5 V |
Voltage input signal | 0 V ... 2 V |
Voltage input signal | 0 V ... 2.4 V |
Voltage input signal | 0 V ... 3 V |
Max. voltage input signal | approx. 3 V DC |
Input resistance of voltage input | approx. 10 kΩ |
Signal: Voltage/current
Number of Outputs | 1 |
Configurable/programmable | Yes, unconfigured |
Voltage output signal | 0 V ... 10 V |
Voltage output signal | 2 V ... 10 V |
Voltage output signal | 0 V ... 5 V |
Voltage output signal | 1 V ... 5 V |
Voltage output signal | -10 V ... 10 V (The bi-polar output can be used only for bi-polar input signals.) |
Voltage output signal | -5 V ... 5 V (The bi-polar output can be used only for bi-polar input signals.) |
Current Output Signal | 0 mA ... 20 mA |
Current Output Signal | 4 mA ... 20 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/Output Load Current Output | < 500 Ω (at 20 mA) |
Ripple | < 20 mVPP (at 500 Ω) |
Ripple | < 20 mVPP (at 10 kΩ) |
Connection data
Connection Method | Spring-cage connection |
Connection technology | 2-conductor |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Dimensions
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 102.5 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA/Canada
Identification | UL 508 Recognized |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Shipbuilding approval
Certificate | DNV GL TAA000020N |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | B |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 6 % |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 6 % |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Comments | Criterion B |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 6 % |
Standards and Regulations
Electrical isolation | Basic insulation in accordance with EN 61010 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2810793?
Proax is an authorized distributor of Phoenix Contact 2810793 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended