Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2902830
Weight
0.082 kg
This product has been discontinued and replaced with MINI MCR-2-UI-I-OLP-PT

MINI MCR-SL-UI-I-LP-SP-NC - Signal conditioner

Output-side-powered 2-way loop-powered signal conditioner, can be configured via DIP switches, with spring-cage connection technology, standard configuration. Replacement part: 2902063 MINI MCR-2-UI-I-OLP-PT.

Technical Specifications

Product properties

Product familyMINI Analog
No. of channels1

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Alignment span± 2 %
Alignment zero± 2 %
Rated Insulation Voltage50 V AC/DC
Electrical isolationBasic insulation in accordance with EN 61010
Electrical isolation between input and outputyes
Limit frequency (3 dB)approx. 30 Hz
Test voltage input/output1.5 kV AC (50 Hz, 60 s)
Step response (10-90%)approx. 16 ms
Maximum temperature coefficient0.01 %/K
Temperature coefficient, typical0.005 %/K
Maximum transmission error< 0.1 % (of final value)
Maximum transmission error< 0.2 % (Without adjustment)

Supply

Supply Voltage Rangeloop-powered, no external supply necessary
Power consumption28 mW (without signal)

Signal

Number of Inputs1
Voltage input signal0 mV ... 1000 mV
Voltage input signal0 mV ... 750 mV
Voltage input signal0 mV ... 500 mV
Voltage input signal0 mV ... 300 mV
Voltage input signal0 mV ... 250 mV
Voltage input signal0 mV ... 200 mV
Voltage input signal0 mV ... 150 mV
Voltage input signal0 mV ... 125 mV
Voltage input signal0 mV ... 120 mV
Voltage input signal0 mV ... 100 mV
Voltage input signal0 mV ... 75 mV
Voltage input signal0 mV ... 60 mV
Voltage input signal0 mV ... 50 mV
Voltage input signal0 V ... 10 V
Voltage input signal0 V ... 7.5 V
Voltage input signal0 V ... 5 V
Voltage input signal0 V ... 3 V
Voltage input signal0 V ... 2.5 V
Voltage input signal0 V ... 2 V
Voltage input signal0 V ... 1.5 V
Voltage input signal0 V ... 1.25 V
Voltage input signal0 V ... 1.2 V
Voltage input signal0 V ... 30 V
Voltage input signal0 V ... 25 V
Voltage input signal0 V ... 20 V
Voltage input signal0 V ... 12.5 V
Voltage input signal0 V ... 12 V
Voltage input signal0 V ... 15 V
Voltage input signal-1000 mV ... 1000 mV
Voltage input signal-750 mV ... 750 mV
Voltage input signal-500 mV ... 500 mV
Voltage input signal-300 mV ... 300 mV
Voltage input signal-250 mV ... 250 mV
Voltage input signal-200 mV ... 200 mV
Voltage input signal-125 mV ... 125 mV
Voltage input signal-120 mV ... 120 mV
Voltage input signal-150 mV ... 150 mV
Voltage input signal-100 mV ... 100 mV
Voltage input signal-75 mV ... 75 mV
Voltage input signal-60 mV ... 60 mV
Voltage input signal-50 mV ... 50 mV
Voltage input signal-10 V ... 10 V
Voltage input signal-7.5 V ... 7.5 V
Voltage input signal-5 V ... 5 V
Voltage input signal-3 V ... 3 V
Voltage input signal-2.5 V ... 2.5 V
Voltage input signal-2 V ... 2 V
Voltage input signal-1.25 V ... 1.25 V
Voltage input signal-1.2 V ... 1.2 V
Voltage input signal-1.5 V ... 1.5 V
Voltage input signal-30 V ... 30 V
Voltage input signal-25 V ... 25 V
Voltage input signal-20 V ... 20 V
Voltage input signal-12.5 V ... 12.5 V
Voltage input signal-12 V ... 12 V
Voltage input signal-15 V ... 15 V
Voltage input signal200 mV ... 1000 mV
Voltage input signal150 mV ... 750 mV
Voltage input signal100 mV ... 500 mV
Voltage input signal60 mV ... 300 mV
Voltage input signal50 mV ... 250 mV
Voltage input signal40 mV ... 200 mV
Voltage input signal25 mV ... 125 mV
Voltage input signal24 mV ... 120 mV
Voltage input signal30 mV ... 150 mV
Voltage input signal20 mV ... 100 mV
Voltage input signal15 mV ... 75 mV
Voltage input signal12 mV ... 60 mV
Voltage input signal10 mV ... 50 mV
Voltage input signal2 V ... 10 V
Voltage input signal1.5 V ... 7.5 V
Voltage input signal1 V ... 5 V
Voltage input signal0.6 V ... 3 V
Voltage input signal0.5 V ... 2.5 V
Voltage input signal0.4 V ... 2 V
Voltage input signal0.25 V ... 1.25 V
Voltage input signal0.24 V ... 1.2 V
Voltage input signal0.3 V ... 1.5 V
Voltage input signal6 V ... 30 V
Voltage input signal5 V ... 25 V
Voltage input signal4 V ... 20 V
Voltage input signal2.5 V ... 12.5 V
Voltage input signal2.4 V ... 12 V
Voltage input signal3 V ... 15 V
Max. voltage input signal< 40 V
Current Input Signal0 mA ... 40 mA
Current Input Signal0 mA ... 30 mA
Current Input Signal0 mA ... 20 mA
Current Input Signal0 mA ... 12 mA
Current Input Signal0 mA ... 10 mA
Current Input Signal0 mA ... 8 mA
Current Input Signal0 mA ... 7.5 mA
Current Input Signal0 mA ... 5 mA
Current Input Signal0 mA ... 6 mA
Current Input Signal0 mA ... 4 mA
Current Input Signal0 mA ... 3 mA
Current Input Signal0 mA ... 2.5 mA
Current Input Signal0 mA ... 2 mA
Current Input Signal-40 mA ... 40 mA
Current Input Signal-30 mA ... 30 mA
Current Input Signal-20 mA ... 20 mA
Current Input Signal-12 mA ... 12 mA
Current Input Signal-10 mA ... 10 mA
Current Input Signal-8 mA ... 8 mA
Current Input Signal-7.5 mA ... 7.5 mA
Current Input Signal-5 mA ... 5 mA
Current Input Signal-6 mA ... 6 mA
Current Input Signal-4 mA ... 4 mA
Current Input Signal-3 mA ... 3 mA
Current Input Signal-2.5 mA ... 2.5 mA
Current Input Signal-2 mA ... 2 mA
Current Input Signal8 mA ... 40 mA
Current Input Signal6 mA ... 30 mA
Current Input Signal4 mA ... 20 mA
Current Input Signal2.4 mA ... 12 mA
Current Input Signal2 mA ... 10 mA
Current Input Signal1.6 mA ... 8 mA
Current Input Signal1.5 mA ... 7.5 mA
Current Input Signal1 mA ... 5 mA
Current Input Signal1.2 mA ... 6 mA
Current Input Signal0.8 mA ... 4 mA
Current Input Signal0.6 mA ... 3 mA
Current Input Signal0.5 mA ... 2.5 mA
Current Input Signal0.4 mA ... 2 mA
Max. current input signal< 50 mA (Dielectric strength up to 30 V)
Input resistance of voltage inputapprox. 100 kΩ (At ≤ 1 V, otherwise approximately 1 MΩ)
Input resistance current input≤ 50 Ω
Number of Outputs1
Configurable/programmableYes, preconfigured
Current Output Signal4 mA ... 20 mA
Max. current output signal35 mA (output limit)
Load/Output Load Current Output< 1000 Ω ((UB - 8 V) / 22 mA)
Ripple< 20 mVPP (at 500 Ω)

Connection data

Connection MethodSpring-cage connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA IIC T4 Gc X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T5
IdentificationClass I, Zone 2, Group IIC

Shipbuilding approval

IdentificationD, EMC1
CertificateDNV GL 14085-15HH

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.5 %
CommentsCriterion A

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value0.5 %
CommentsCriterion A

Standards and Regulations

Electrical isolationBasic insulation in accordance with EN 61010

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-SL-UI-I-LP-SP-NC?

Proax is an authorized distributor of Phoenix Contact MINI MCR-SL-UI-I-LP-SP-NC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCRSLUIILPSPNC
Pack Size1
Recommended