Official Distributor
SKU
MPN
MINI MCR-SL-UI-I-LP-NC
Weight
0.087 kg
MINI MCR-SL-UI-I-LP-NC - Signal conditioner
2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with screw connection technology and standard configuration.
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog |
No. of channels | 1 |
Configuration | DIP switches |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Alignment span | ± 2 % |
Alignment zero | ± 2 % |
Electrical isolation | 2-way isolation |
Electrical isolation between input and output | yes |
Limit frequency (3 dB) | approx. 30 Hz |
Maximum power dissipation for nominal condition | 19 mW |
Step response (10-90%) | approx. 16 ms |
Maximum temperature coefficient | 0.01 %/K |
Temperature coefficient, typical | 0.005 %/K |
Maximum transmission error | < 0.1 % (of final value) |
Maximum transmission error | < 0.2 % (Without adjustment) |
Electrical isolation Input/output
Rated Insulation Voltage | 50 V AC/DC |
Test voltage | 1.5 kV AC (50 Hz, 60 s) |
Insulation | Basic insulation in accordance with IEC/EN 61010 |
Supply
Supply Voltage Range | loop-powered, no external supply necessary |
Power consumption | 28 mW (without signal) |
Signal: Voltage/current
Number of Inputs | 1 |
Voltage input signal | 0 mV ... 1000 mV |
Voltage input signal | 0 mV ... 750 mV |
Voltage input signal | 0 mV ... 500 mV |
Voltage input signal | 0 mV ... 300 mV |
Voltage input signal | 0 mV ... 250 mV |
Voltage input signal | 0 mV ... 200 mV |
Voltage input signal | 0 mV ... 150 mV |
Voltage input signal | 0 mV ... 125 mV |
Voltage input signal | 0 mV ... 120 mV |
Voltage input signal | 0 mV ... 100 mV |
Voltage input signal | 0 mV ... 75 mV |
Voltage input signal | 0 mV ... 60 mV |
Voltage input signal | 0 mV ... 50 mV |
Voltage input signal | 0 V ... 10 V |
Voltage input signal | 0 V ... 7.5 V |
Voltage input signal | 0 V ... 5 V |
Voltage input signal | 0 V ... 3 V |
Voltage input signal | 0 V ... 2.5 V |
Voltage input signal | 0 V ... 2 V |
Voltage input signal | 0 V ... 1.5 V |
Voltage input signal | 0 V ... 1.25 V |
Voltage input signal | 0 V ... 1.2 V |
Voltage input signal | 0 V ... 30 V |
Voltage input signal | 0 V ... 25 V |
Voltage input signal | 0 V ... 20 V |
Voltage input signal | 0 V ... 12.5 V |
Voltage input signal | 0 V ... 12 V |
Voltage input signal | 0 V ... 15 V |
Voltage input signal | -1000 mV ... 1000 mV |
Voltage input signal | -750 mV ... 750 mV |
Voltage input signal | -500 mV ... 500 mV |
Voltage input signal | -300 mV ... 300 mV |
Voltage input signal | -250 mV ... 250 mV |
Voltage input signal | -200 mV ... 200 mV |
Voltage input signal | -125 mV ... 125 mV |
Voltage input signal | -120 mV ... 120 mV |
Voltage input signal | -150 mV ... 150 mV |
Voltage input signal | -100 mV ... 100 mV |
Voltage input signal | -75 mV ... 75 mV |
Voltage input signal | -60 mV ... 60 mV |
Voltage input signal | -50 mV ... 50 mV |
Voltage input signal | -10 V ... 10 V |
Voltage input signal | -7.5 V ... 7.5 V |
Voltage input signal | -5 V ... 5 V |
Voltage input signal | -3 V ... 3 V |
Voltage input signal | -2.5 V ... 2.5 V |
Voltage input signal | -2 V ... 2 V |
Voltage input signal | -1.25 V ... 1.25 V |
Voltage input signal | -1.2 V ... 1.2 V |
Voltage input signal | -1.5 V ... 1.5 V |
Voltage input signal | -30 V ... 30 V |
Voltage input signal | -25 V ... 25 V |
Voltage input signal | -20 V ... 20 V |
Voltage input signal | -12.5 V ... 12.5 V |
Voltage input signal | -12 V ... 12 V |
Voltage input signal | -15 V ... 15 V |
Voltage input signal | 200 mV ... 1000 mV |
Voltage input signal | 150 mV ... 750 mV |
Voltage input signal | 100 mV ... 500 mV |
Voltage input signal | 60 mV ... 300 mV |
Voltage input signal | 50 mV ... 250 mV |
Voltage input signal | 40 mV ... 200 mV |
Voltage input signal | 25 mV ... 125 mV |
Voltage input signal | 24 mV ... 120 mV |
Voltage input signal | 30 mV ... 150 mV |
Voltage input signal | 20 mV ... 100 mV |
Voltage input signal | 15 mV ... 75 mV |
Voltage input signal | 12 mV ... 60 mV |
Voltage input signal | 10 mV ... 50 mV |
Voltage input signal | 2 V ... 10 V (additional areas can be configured, see table) |
Voltage input signal | 1.5 V ... 7.5 V |
Voltage input signal | 1 V ... 5 V |
Voltage input signal | 0.6 V ... 3 V |
Voltage input signal | 0.5 V ... 2.5 V |
Voltage input signal | 0.4 V ... 2 V |
Voltage input signal | 0.25 V ... 1.25 V |
Voltage input signal | 0.24 V ... 1.2 V |
Voltage input signal | 0.3 V ... 1.5 V |
Voltage input signal | 6 V ... 30 V |
Voltage input signal | 5 V ... 25 V |
Voltage input signal | 4 V ... 20 V |
Voltage input signal | 2.5 V ... 12.5 V |
Voltage input signal | 2.4 V ... 12 V |
Voltage input signal | 3 V ... 15 V |
Max. voltage input signal | < 40 V |
Current Input Signal | 0 mA ... 40 mA |
Current Input Signal | 0 mA ... 30 mA |
Current Input Signal | 0 mA ... 20 mA |
Current Input Signal | 0 mA ... 12 mA |
Current Input Signal | 0 mA ... 10 mA |
Current Input Signal | 0 mA ... 8 mA |
Current Input Signal | 0 mA ... 7.5 mA |
Current Input Signal | 0 mA ... 5 mA |
Current Input Signal | 0 mA ... 6 mA |
Current Input Signal | 0 mA ... 4 mA |
Current Input Signal | 0 mA ... 3 mA |
Current Input Signal | 0 mA ... 2.5 mA |
Current Input Signal | 0 mA ... 2 mA |
Current Input Signal | -40 mA ... 40 mA |
Current Input Signal | -30 mA ... 30 mA |
Current Input Signal | -20 mA ... 20 mA |
Current Input Signal | -12 mA ... 12 mA |
Current Input Signal | -10 mA ... 10 mA |
Current Input Signal | -8 mA ... 8 mA |
Current Input Signal | -7.5 mA ... 7.5 mA |
Current Input Signal | -5 mA ... 5 mA |
Current Input Signal | -6 mA ... 6 mA |
Current Input Signal | -4 mA ... 4 mA |
Current Input Signal | -3 mA ... 3 mA |
Current Input Signal | -2.5 mA ... 2.5 mA |
Current Input Signal | -2 mA ... 2 mA |
Current Input Signal | 8 mA ... 40 mA |
Current Input Signal | 6 mA ... 30 mA |
Current Input Signal | 4 mA ... 20 mA |
Current Input Signal | 2.4 mA ... 12 mA |
Current Input Signal | 2 mA ... 10 mA |
Current Input Signal | 1.6 mA ... 8 mA |
Current Input Signal | 1.5 mA ... 7.5 mA |
Current Input Signal | 1 mA ... 5 mA |
Current Input Signal | 1.2 mA ... 6 mA |
Current Input Signal | 0.8 mA ... 4 mA |
Current Input Signal | 0.6 mA ... 3 mA |
Current Input Signal | 0.5 mA ... 2.5 mA |
Current Input Signal | 0.4 mA ... 2 mA |
Max. current input signal | < 50 mA (Dielectric strength up to 30 V) |
Input resistance of voltage input | 100 kΩ (≤ 1 V) |
Input resistance of voltage input | 1 MΩ (≥ 1 V) |
Input resistance current input | ≤ 50 Ω |
Signal
Number of Outputs | 1 |
Configurable/programmable | Yes, preconfigured |
Current Output Signal | 4 mA ... 20 mA |
Max. current output signal | 35 mA (output limit) |
Load/Output Load Current Output | < 1000 Ω ((UB - 8 V) / 22 mA) |
Ripple | < 20 mVPP (at 500 Ω) |
Connection data
Connection Method | Screw connection |
Stripping length | 12 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 12 |
Dimensions
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 101.2 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T5 |
Identification | Class I, Zone 2, Group IIC |
Shipbuilding approval
Certificate | DNV GL TAA00002R0 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | B |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 0.5 % |
Comments | Criterion A |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 2 % |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Comments | Criterion B |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 0.5 % |
Comments | Criterion A |
Standards and Regulations
Electrical isolation | 2-way isolation |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902829?
Proax is an authorized distributor of Phoenix Contact 2902829 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended