Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2864082
Weight
0.108 kg

MINI MCR-SL-UI-F - Frequency measuring transducer

Analog frequency transducers for converting analog standard signals into frequency signals or PWM signals, configurable via DIP switch, with screw connection

  • Power supply possible via the foot element (TBUS)
  • Error indication via diagnostic LED and analog signal
  • PWM output of 5 ... 95 %
  • Highly-compact analog-to-frequency transducer for electrical isolation, amplification, conversion, and filtering of standard signals to create frequencies or PWM signals
  • Input and output signals can be configured via DIP switches
  • Configurable interference filter
  • 3-way isolation
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog
No. of channels1
ConfigurationDIP switches

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches

Electrical properties

Electrical isolation between input and outputyes
Step response (0–99%)< 15 ms (+ (1/f) smallest filter)
Step response (0–99%)< 1 s (+ (1/f) largest filter)
Maximum temperature coefficient< 0.02 %/K
Temperature coefficient, typical< 0.02 %/K
Maximum transmission error≤ 0.1 % (> 7 kHz ≤ 0.2 %)

Electrical isolation Input/output/power supply

Rated Insulation Voltage30 V AC
Rated Insulation Voltage50 V DC
Test voltage1.5 kV AC (50 Hz, 60 s)
InsulationBasic insulation in accordance with IEC/EN 61010

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 10 mA (at 24 V DC)
Power consumption< 200 mW

Signal: Voltage/current

Number of Inputs1
Configurable/programmableYes
Voltage input signal0 V ... 5 V
Voltage input signal1 V ... 5 V
Voltage input signal0 V ... 10 V
Voltage input signal2 V ... 10 V
Max. voltage input signal30 V DC
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Current Input Signal0 mA ... 10 mA
Current Input Signal2 mA ... 10 mA
Max. current input signal100 mA
Input resistance of voltage inputapprox. 110 kΩ
Input resistance current inputapprox. 50 Ω
Behavior in the event of an errorAlarm in the form of a red LED

Frequency: Frequency

Frequency output0 Hz ... 10 kHz
Frequency output0 Hz ... 5 kHz
Frequency output0 Hz ... 2.5 kHz
Frequency output0 Hz ... 1 kHz
Frequency output0 Hz ... 500 Hz
Frequency output0 Hz ... 250 Hz
Frequency output0 Hz ... 100 Hz
Frequency output0 Hz ... 50 Hz
Load min.4 mA ≤ (UL / RL) ≤ 20 mA
Output signal PWM7.8 kHz (10 bit)
Output signal PWM3.9 kHz (10 bit)
Output signal PWM1.9 kHz (12 bit)
Output signal PWM977 Hz (12 bit)
Output signal PWM488 Hz (14 bit)
Output signal PWM244 Hz (14 bit)
Output signal PWM122 Hz (16 bit)
Output signal PWM61 Hz (16 bit)
Load min.12 mA ≤ (UL/RL) ≤ 20 mA
Load current maximum20 mA
Maximum Switching Voltage30 V
Overrange/underrangecan be set (via DIP switch)
Protective circuitShort-circuit protection, polarity reversal protection

Signal

Number of Outputs1

Connection data

Connection MethodScrew connection
Stripping length12 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth101.2 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

UL, USA/Canada

IdentificationUL 508 Recognized
IdentificationClass I, Div. 2, Groups A, B, C, D T4

Shipbuilding approval

CertificateDNV GL TAA000020N

DNV GL data

TemperatureB
HumidityB
VibrationB
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value2 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2 %

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-SL-UI-F?

Proax is an authorized distributor of Phoenix Contact MINI MCR-SL-UI-F and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCRSLUIF
Pack Size1
Recommended

Available for order