Official Distributor
SKU
MPN
MINI MCR-SL-RPSS-I-I-SP
Weight
0.113 kg
MINI MCR-SL-RPSS-I-I-SP - Repeater power supply
MCR repeater power supply with HART transmission, input signal: 4 mA...20 mA, output signal: 4 mA...20 mA, with spring-cage connection. Replacement part: 2902015 MINI MCR-2-RPSS-I-I-PT.
- Power supply possible via the foot element (TBUS)
- Bidirectional HART transmission as an option
- Can be used as an isolator with passive input
- Supply of 2-conductor and passive 3-conductor sensors
- 3-way isolation
- Highly-compact repeater power supplies for electrical isolation, amplification, and filtering of standard analog signals
Technical Specifications
Product properties
Product family | MINI Analog |
No. of channels | 1 |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Rated Insulation Voltage | 50 V AC/DC |
Electrical isolation | Basic insulation in accordance with EN 61010 |
Electrical isolation between input and output | yes |
Limit frequency (3 dB) | 175 Hz (typ.) |
Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) |
Protective circuit | Transient protection |
Signal transmission behavior | In = Out |
Step response (10-90%) | < 2 ms |
Maximum temperature coefficient | < 0.005 %/K |
Temperature coefficient, typical | < 0.002 %/K |
Maximum transmission error | ≤ 0.2 % (of final value) |
Transmission error, typical | ≤ 0.1 % (of final value) |
Supply
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 20.4 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Power consumption | < 900 mW (at 24 V DC and in repeater power supply operation) |
Power consumption | < 600 mW (at 24 V DC and in isolator operation) |
Signal
Description of the input | Current input (sensor circuit) |
Number of Inputs | 1 |
Current Input Signal | 4 mA ... 20 mA (repeater power supply and isolator operation) |
Current Input Signal | 0 mA ... 20 mA (isolator operation) |
Input resistance current input | approx. 50 Ω |
Transmitter supply voltage | 16.5 V |
Signal: Current
Number of Outputs | 1 |
Non-load voltage | approx. 12.5 V |
Current Output Signal | 0 mA ... 20 mA (isolator operation) |
Current Output Signal | 4 mA ... 20 mA (repeater power supply and isolator operation) |
Max. current output signal | > 21 mA (22.5 mA, typical) |
Load/Output Load Current Output | ≤ 500 Ω (I = 20 mA) |
Ripple | < 20 mVrms (at 500 Ω) |
Connection data
Connection Method | Spring-cage connection |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Data communication (bypass)
HART Function | Yes |
Limit frequency (3 dB) | approx. 2.5 Hz |
Dimensions
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 102.5 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Identification | Class I, Zone 2, Group IIC |
Shipbuilding approval
Identification | BBBAA |
Certificate | DNV GL TAA00000N1 |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 3 % |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 3 % |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Comments | Criterion B |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 3 % |
Standards and Regulations
Electrical isolation | Basic insulation in accordance with EN 61010 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2810230?
Proax is an authorized distributor of Phoenix Contact 2810230 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- MINI MCR-SL-PT100-UI-SP, The 6.2 mm wide MINI MCR-SL-PT100-UI... is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.On the output side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V, 0...5 V, 1...5 V, 10...0 V, 20...0 mA or 20...4 mA are available, electrically isolated.The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:- Connection method- Temperature range to be measured- Output signal as well- Fault evaluation typePower (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
- MINI MCR-SL-PT100-UI-SP-NC, The 6.2 mm wide MINI MCR-SL-PT100-UI... is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.On the output side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V, 0...5 V, 1...5 V, 10...0 V, 20...0 mA or 20...4 mA are available, electrically isolated.The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:- Connection method- Temperature range to be measured- Output signal as well- Fault evaluation typePower (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.