MINI MCR-SL-PT100-UI-SP-NC - Resistance thermometer measuring transducer

MCR temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with spring-cage connection, not preconfigured. Replacement part: 2902052 MINI MCR-2-RTD-UI-PT.

  • Power supply possible via the foot element (TBUS)
  • For 2-, 3-, 4-conductor Pt 100 sensors in accordance with IEC 60751
  • Error indication via diagnostic LED and analog signal
  • Temperature measuring range of -150°C to +850°C
  • Input and output signals can be configured via DIP switches
  • 3-way isolation
  • Pt 100 signals to create standard signals
  • Highly-compact temperature transducer for electrical isolation, conversion, amplification, and filtering of
Technical Specifications

Product properties

Product familyMINI Analog
No. of channels1

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Rated Insulation Voltage50 V AC/DC
Electrical isolationBasic insulation in accordance with EN 61010
Maximum power dissipation for nominal condition235.5 mW
Test voltage, input/output/supply1.5 kV AC (50 Hz, 60 s)
Protective circuitTransient protection
Step response (0–99%)< 160 ms
Maximum temperature coefficient< 0.02 %/K
Transmission error in the set measuring range((100 K / set measurement range [K]) + 0.1)%
Transmission error in the full measuring range≤ 0,2 %

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 21 mA (at 24 V DC)
Power consumption< 500 mW

Signal

Number of Inputs1
Input SignalTemperature

Measurement

Configurable/programmableYes
Sensor types (RTD) that can be usedPt 100 (IEC 60751/EN 60751)
Temperature measuring rangemin. 50 K
Sensor type: -150 °C ... 850 °C (configurable)
Sensor input current1 mA (constant)
Max. permissible overall conductor resistance10 Ω (Per cable)
Connection technology2-, 3-, 4-conductor

Signal

Number of Outputs1
Configurable/programmableYes, unconfigured
Voltage output signal0 V ... 10 V
Voltage output signal10 V ... 0 V
Voltage output signal0 V ... 5 V
Voltage output signal1 V ... 5 V
Max. voltage output signalapprox. 12.5 V
Non-load voltageapprox. 12.5 V
Current Output Signal0 mA ... 20 mA
Current Output Signal20 mA ... 0 mA
Current Output Signal20 mA ... 4 mA
Current Output Signal4 mA ... 20 mA
Max. current output signal23 mA
Short-circuit currentapprox. 10 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output< 500 Ω (at 20 mA)
Ripple< 20 mVPP (at 500 Ω)
Ripple< 20 mVPP (at 500 Ω)

Connection data

Connection MethodSpring-cage connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA IIC T4 Gc X

UL, USA/Canada

IdentificationUL 508 Recognized
IdentificationClass I, Div. 2, Groups A, B, C, D T5

GL

IdentificationGL EMC 2 D

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value10 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value10 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value10 %

Standards and Regulations

Electrical isolationBasic insulation in accordance with EN 61010

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2864286?

Proax is an authorized distributor of Phoenix Contact 2864286 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability