Official Distributor
SKU
MPN
MINI MCR-SL-NAM-2RNO-SP
Weight
0.094 kg
This product is Not Cancellable/Not Returnable
Series MINI-MCR-SL-NAM
MINI MCR-SL-NAM-2RNO-SP - Switching amplifier
NAMUR switching amplifier for proximity sensors, can be configured, floating switching contacts and switching contacts with a resistance circuit. Output-side 2 N/O contact, with spring-cage connection, can be configured. Replacement part: 2902005 MINI MCR-2-NAM-2RO-PT.
- Floating contacts and contacts with resistance circuit can be connected
- Power supply possible via the foot element (TBUS)
- Highly compact isolation amplifier for electrical isolation, amplification, and duplication of proximity sensor signals
- For proximity sensors according to IEC 60947-5-6 and EN 50227
- Error indication via diagnostic LED and analog signal
- Second output can be used as a duplicator or error signaling output
- N/O contacts at output
- Input and output signals can be configured via DIP switches
- 3-way isolation
- Operating current/closed circuit current switch-over (inverted switching behavior)
Technical Specifications
Product properties
Product family | MINI Analog |
No. of channels | 1 |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Rated Insulation Voltage | 150 V AC (Input/relay outputs (reinforced insulation)) |
Rated Insulation Voltage | 150 V AC (Supply/relay outputs (reinforced insulation)) |
Rated Insulation Voltage | 150 V AC (Relay output 1/relay output 2 (reinforced insulation)) |
Rated Insulation Voltage | 30 V AC (Input/supply) |
Rated Insulation Voltage | 50 V DC (Input/supply) |
Electrical isolation | Reinforced insulation in accordance with EN 61010-1 |
Electrical isolation between input and output | yes |
Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) |
Supply
Designation | Supply |
Nominal Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC |
Max. current consumption | < 25 mA |
Power consumption | < 600 mW |
Signal: NAMUR
Number of Inputs | 1 |
Available Input Sources | NAMUR proximity sensors (IEC/EN 60947-5-6) |
Available Input Sources | Floating switch contacts |
Available Input Sources | Switch contacts with resistance circuit |
Switching threshold "0" signal current | < 1.2 mA (blocking) |
Switching threshold "1" signal, current | > 2.1 mA (conductive) |
Line fault detection | > 6 mA (Short circuit) |
Line fault detection | < 0.35 mA (Line break) |
Line fault detection | Activated /deactivated via DIP switch |
Non-load voltage | 8.2 V DC ±10 % |
Switching:
Maximum Switching Voltage | 250 V AC |
Maximum Switching Voltage | 125 V DC |
Maximum Switching Voltage | 150 V AC (UL) |
Maximum Switching Voltage | 125 V DC (UL) |
Signal
Number of Outputs | 2 |
Connection data
Connection Method | Spring-cage connection |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Dimensions
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 102.5 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA nC IIC T4 Gc X |
UL, USA/Canada
Identification | UL 508 Recognized |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Shipbuilding approval
Identification | BBBAA |
Certificate | DNV GL TAA00000N1 |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Evaluation criterion | A |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Evaluation criterion | A |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Evaluation criterion | A |
Standards and Regulations
Electrical isolation | Reinforced insulation in accordance with EN 61010-1 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2810269?
Proax is an authorized distributor of Phoenix Contact 2810269 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- MINI MCR-SL-PT100-UI-SP, The 6.2 mm wide MINI MCR-SL-PT100-UI... is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.On the output side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V, 0...5 V, 1...5 V, 10...0 V, 20...0 mA or 20...4 mA are available, electrically isolated.The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:- Connection method- Temperature range to be measured- Output signal as well- Fault evaluation typePower (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
- MINI MCR-SL-PT100-UI-SP-NC, The 6.2 mm wide MINI MCR-SL-PT100-UI... is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.On the output side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V, 0...5 V, 1...5 V, 10...0 V, 20...0 mA or 20...4 mA are available, electrically isolated.The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:- Connection method- Temperature range to be measured- Output signal as well- Fault evaluation typePower (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.