MINI MCR-SL-PT100-UI-200-NC - Temperature measuring transducer

MCR temperature transducer, configurable, for Pt 100 temperature sensors, with screw-connection, not configured

  • Power supply possible via the foot element (TBUS)
  • Optimized temperature measuring range of -50°C to +200°C for increased accuracy
  • For 2-, 3-, 4-conductor Pt 100 sensors in accordance with IEC 60751
  • Error indication via diagnostic LED and analog signal
  • Pt 100 signals to create standard signals
  • 3-way isolation
  • Highly-compact temperature transducer for electrical isolation, conversion, amplification, and filtering of
  • Input and output signals can be configured via DIP switches
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog
ConfigurationDIP switches

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition235.5 mW
Protective circuitTransient protection
Step response (0–99%)< 200 ms
Maximum temperature coefficient< 0.02 %/K
Transmission error in the set measuring range((50 K / Δ Temp)+ 0.05)%
Transmission error in the full measuring range≤ 0.25 %

Electrical isolation Input/output/power supply

Rated Insulation Voltage50 V AC/DC
Test voltage1.5 kV AC (50 Hz, 60 s)
InsulationBasic insulation in accordance with IEC/EN 61010

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 21 mA (at 24 V DC)
Power consumption< 500 mW

Signal

Number of Inputs1

Measurement

Sensor types (RTD) that can be usedPt 100 (IEC 60751/EN 60751)
Temperature measuring rangemin. 50 K
Sensor type: -50 °C ... 200 °C (configurable)
Sensor input current1 mA (constant)
Max. permissible overall conductor resistance10 Ω (Per cable)
Connection technology2-, 3-, 4-conductor

Signal: Voltage/current

Number of Outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V
Voltage output signal1 V ... 5 V
Voltage output signal0 V ... 10 V
Voltage output signal10 V ... 0 V
Max. voltage output signal 12.5 V
Non-load voltage 12.5 V
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Current Output Signal20 mA ... 0 mA
Current Output Signal20 mA ... 4 mA
Max. current output signal23 mA
Short-circuit current 10 mA
Load/output load voltage output> 10 kΩ
Load/Output Load Current Output< 500 Ω (at 20 mA)
Ripple< 20 mVPP (at 500 Ω)
Ripple< 20 mVPP (at 10 kΩ)

Connection data

Connection MethodScrew connection
Stripping length12 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth101.2 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

UL, USA/Canada

IdentificationUL 508 Recognized
IdentificationClass I, Div. 2, Groups A, B, C, D T5

Shipbuilding approval

CertificateDNV GL TAA00002R0

DNV GL data

TemperatureB
HumidityB
VibrationB
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value10 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value10 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value10 %

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-SL-PT100-UI-200-NC?

Proax is an authorized distributor of Phoenix Contact MINI MCR-SL-PT100-UI-200-NC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCRSLPT100UI200NC
Pack Size1
Recommended

Available for order