MINI MCR-SL-SHUNT-UI-NC - Signal conditioner

MCR 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range, both unipolar and bipolar with screw connection, not preconfigured

  • Power supply possible via the foot element (TBUS)
  • Ideal for converting signals for shunt measurements
  • Low power consumption
  • Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of mV signals to create standard analog signals
  • Up to 280 signal combinations can be configured using DIP switches
  • 3-way isolation
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog
No. of channels1
ConfigurationDIP switches

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolationBasic insulation in accordance with EN 61010
Electrical isolation between input and outputyes
Limit frequency (3 dB)100 Hz / 30 Hz switchable
Step response (10-90%)3.5 ms (100 Hz)
Maximum temperature coefficient< 0.01 %/K
Temperature coefficient, typical< 0.002 %/K
Maximum transmission error≤ 0.2 %
Maximum transmission error< 0.4 % (Without adjustment)

Electrical isolation Input/output/power supply

Rated Insulation Voltage30 V AC
Rated Insulation Voltage50 V DC
Test voltage1.5 kV AC (50 Hz, 60 s)

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 25 mA
Power consumption< 450 mW (Current output)

Signal: Voltage

Number of Inputs1
Configurable/programmableYes, unconfigured
Voltage input signal-50 mV ... 50 mV
Voltage input signal-60 mV ... 60 mV
Voltage input signal-75 mV ... 75 mV
Voltage input signal-80 mV ... 80 mV
Voltage input signal-100 mV ... 100 mV
Voltage input signal-120 mV ... 120 mV
Voltage input signal-150 mV ... 150 mV
Voltage input signal-200 mV ... 200 mV
Voltage input signal-240 mV ... 240 mV
Voltage input signal-300 mV ... 300 mV
Voltage input signal-500 mV ... 500 mV
Voltage input signal-600 mV ... 600 mV
Voltage input signal-750 mV ... 750 mV
Voltage input signal-800 mV ... 800 mV
Voltage input signal-1 V ... 1 V
Voltage input signal-1.2 V ... 1.2 V
Voltage input signal-1.5 V ... 1.5 V
Voltage input signal-2 V ... 2 V
Voltage input signal-2.4 V ... 2.4 V
Voltage input signal-3 V ... 3 V
Voltage input signal0 mV ... 50 mV (additional areas can be configured, see table)
Voltage input signal0 mV ... 60 mV
Voltage input signal0 mV ... 75 mV
Voltage input signal0 mV ... 80 mV
Voltage input signal0 mV ... 100 mV
Voltage input signal0 mV ... 120 mV
Voltage input signal0 mV ... 150 mV
Voltage input signal0 mV ... 200 mV
Voltage input signal0 mV ... 240 mV
Voltage input signal0 mV ... 300 mV
Voltage input signal0 mV ... 500 mV
Voltage input signal0 mV ... 600 mV
Voltage input signal0 mV ... 750 mV
Voltage input signal0 mV ... 800 mV
Voltage input signal0 V ... 1 V
Voltage input signal0 V ... 1.2 V
Voltage input signal0 V ... 1.5 V
Voltage input signal0 V ... 2 V
Voltage input signal0 V ... 2.4 V
Voltage input signal0 V ... 3 V
Max. voltage input signalapprox. 3 V DC
Input resistance of voltage inputapprox. 10 kΩ

Signal: Voltage/current

Number of Outputs1
Configurable/programmableYes, unconfigured
Voltage output signal0 V ... 10 V
Voltage output signal2 V ... 10 V
Voltage output signal0 V ... 5 V
Voltage output signal1 V ... 5 V
Voltage output signal-10 V ... 10 V (The bi-polar output can be used only for bi-polar input signals.)
Voltage output signal-5 V ... 5 V (The bi-polar output can be used only for bi-polar input signals.)
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output< 500 Ω (at 20 mA)
Ripple< 20 mVPP (at 500 Ω)
Ripple< 20 mVPP (at 10 kΩ)

Connection data

Connection MethodScrew connection
Connection technology2-conductor
Stripping length12 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

UL, USA/Canada

IdentificationUL 508 Recognized
IdentificationClass I, Div. 2, Groups A, B, C, D T4

Shipbuilding approval

CertificateDNV GL TAA000020N

DNV GL data

TemperatureB
HumidityB
VibrationB
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value6 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value6 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value6 %

Standards and Regulations

Electrical isolationBasic insulation in accordance with EN 61010

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-SL-SHUNT-UI-NC?

Proax is an authorized distributor of Phoenix Contact MINI MCR-SL-SHUNT-UI-NC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCRSLSHUNTUINC
Pack Size1
Recommended

Available for order