Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2864493
Weight
0.094 kg
This product has been discontinued and replaced with MINI MCR-2-UI-REL-PT

MINI MCR-SL-UI-REL-SP - Limit value switch

MCR threshold value switch, with adjustable hysteresis and delay time, with spring-cage connection. Replacement part: 2902035 MINI MCR-2-UI-REL-PT.

  • Power supply possible via the foot element (TBUS)
  • Highly-compact threshold value switch for switching analog limit values
  • Status and error indication via two diagnostic LEDs
  • Changeover contact relay at the output
  • 3-way isolation
  • Limit value can be freely adjusted via potentiometer on the front
  • Input signal, hysteresis, and delay time can be configured via DIP switches
  • Operating current/closed circuit current switch-over
Technical Specifications

Product properties

Product familyMINI Analog
No. of channels1

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Rated Insulation Voltage50 V AC/DC
Electrical isolationBasic insulation in accordance with EN 61010
Electrical isolation between input and outputyes
Test voltage input/power supply1.5 kV AC (50 Hz, 60 s)
Switching point accuracy< 0.05 %
Step response (0–99%)< 35 ms
Maximum temperature coefficient< 0.02 %/K

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 14 mA (at 24 V DC)
Power consumption< 330 mW (at 24 V DC)

Signal

Number of Inputs1
Voltage input signal0 V ... 10 V
Max. voltage input signal30 V
Current Input Signal0 mA ... 20 mA
Max. current input signal100 mA
Input resistance of voltage input> 100 kΩ
Input resistance current input50 Ω
Specification of the switching pointWith 25-speed potentiometer

Switching: Relay

Contact switching type1 changeover contact
Contact MaterialAgSnO2, hard gold-plated
Maximum Switching Voltage250 V AC
Maximum Switching Voltage240 V AC (UL)
Limiting Continuous Current2 A
Setting range of the response delay0 s ... 10 s (0 s, 1 s, 2 s, 3 s, 4 s, 6 s  8 s, 10 s)
Internal hysteresis0.1 %, 1 %, 2.5 %, 5 %

Signal

Number of Outputs1

Connection data

Connection MethodSpring-cage connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA nC IIC T4 Gc X

UL, USA

IdentificationClass I, Zone 2, AEx nA nC IIC T5

UL, USA/Canada

IdentificationUL 508 Recognized

UL, Canada

IdentificationClass I, Zone 2, Ex nA nC IIC T5 Gc

GL

IdentificationGL EMC 2 D

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value5 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value5 %

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value5 %

Standards and Regulations

Electrical isolationBasic insulation in accordance with EN 61010

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact MINI MCR-SL-UI-REL-SP?

Proax is an authorized distributor of Phoenix Contact MINI MCR-SL-UI-REL-SP and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMINIMCRSLUIRELSP
Pack Size1
Recommended

Available for order