Series MINI-MCR
MINI MCR-2-U-UI-PT - Signal conditioner
3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Push-in connection technology, standard configuration.
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
| Product family | MINI Analog Pro |
| No. of channels | 1 |
| Type | Signal conditioner |
| Configuration | DIP switches |
Insulation characteristics: GB Standard
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Electrical isolation | 3-way isolation |
| Electrical isolation between input and output | yes |
| Limit frequency (3 dB) | 30 Hz (via DIP switch) |
| Limit frequency (3 dB) | 5 kHz (via DIP switch) |
| Protective circuit | Transient protection |
| Step response (10-90%) | < 8.5 ms (with 30 Hz filter) |
| Maximum temperature coefficient | 0.01 %/K |
| Maximum transmission error | ≤ 0.1 % (of final value) |
Electrical isolation Input/output/power supply
| Rated Insulation Voltage | 300 Vrms |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
| Nominal Supply Voltage | 24 V DC |
| Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Typical current consumption | 25 mA (Current output, at 24 V DC incl. load) |
| Typical current consumption | 54 mA (Current output, at 12 V DC incl. load) |
| Power consumption | ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) |
Signal: Voltage
| Number of Inputs | 1 |
| Configurable/programmable | Yes |
| Input Signal | Voltage |
| Voltage input signal | -50 mV ... 50 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 50 mV (via DIP switch) |
| Voltage input signal | -60 mV ... 60 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 60 mV (via DIP switch) |
| Voltage input signal | -75 mV ... 75 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 75 mV (via DIP switch) |
| Voltage input signal | -80 mV ... 80 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 80 mV (via DIP switch) |
| Voltage input signal | -100 mV ... 100 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 100 mV (via DIP switch) |
| Voltage input signal | -120 mV ... 120 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 120 mV (via DIP switch) |
| Voltage input signal | -150 mV ... 150 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 150 mV (via DIP switch) |
| Voltage input signal | -200 mV ... 200 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 200 mV (via DIP switch) |
| Voltage input signal | -240 mV ... 240 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 240 mV (via DIP switch) |
| Voltage input signal | -300 mV ... 300 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 300 mV (via DIP switch) |
| Voltage input signal | -500 mV ... 500 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 500 mV (via DIP switch) |
| Voltage input signal | -600 mV ... 600 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 600 mV (via DIP switch) |
| Voltage input signal | -750 mV ... 750 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 750 mV (via DIP switch) |
| Voltage input signal | -800 mV ... 800 mV (via DIP switch) |
| Voltage input signal | 0 mV ... 800 mV (via DIP switch) |
| Voltage input signal | -1 V ... 1 V (via DIP switch) |
| Voltage input signal | 0 V ... 1 V (via DIP switch) |
| Voltage input signal | -1.2 V ... 1.2 V (via DIP switch) |
| Voltage input signal | 0 V ... 1.2 V (via DIP switch) |
| Voltage input signal | -1.5 V ... 1.5 V (via DIP switch) |
| Voltage input signal | 0 V ... 1.5 V (via DIP switch) |
| Voltage input signal | -2 V ... 2 V (via DIP switch) |
| Voltage input signal | 0 V ... 2 V (via DIP switch) |
| Voltage input signal | -2.4 V ... 2.4 V (via DIP switch) |
| Voltage input signal | 0 V ... 2.4 V (via DIP switch) |
| Voltage input signal | -3 V ... 3 V (via DIP switch) |
| Voltage input signal | 0 V ... 3 V (via DIP switch) |
| Voltage input signal | -5 V ... 5 V (via DIP switch) |
| Voltage input signal | 0 V ... 5 V (via DIP switch) |
| Voltage input signal | -6 V ... 6 V (via DIP switch) |
| Voltage input signal | 0 V ... 6 V (via DIP switch) |
| Voltage input signal | -7.5 V ... 7.5 V (via DIP switch) |
| Voltage input signal | 0 V ... 7.5 V (via DIP switch) |
| Voltage input signal | -8 V ... 8 V (via DIP switch) |
| Voltage input signal | 0 V ... 8 V (via DIP switch) |
| Voltage input signal | -10 V ... 10 V (via DIP switch) |
| Voltage input signal | 0 V ... 10 V (via DIP switch) |
| Voltage input signal | -12 V ... 12 V (via DIP switch) |
| Voltage input signal | 0 V ... 12 V (via DIP switch) |
| Voltage input signal | -15 V ... 15 V (via DIP switch) |
| Voltage input signal | 0 V ... 15 V (via DIP switch) |
| Voltage input signal | -20 V ... 20 V (via DIP switch) |
| Voltage input signal | 0 V ... 20 V (via DIP switch) |
| Voltage input signal | -24 V ... 24 V (via DIP switch) |
| Voltage input signal | 0 V ... 24 V (via DIP switch) |
| Voltage input signal | -30 V ... 30 V (via DIP switch) |
| Voltage input signal | 0 V ... 30 V (via DIP switch) |
| Max. voltage input signal | 33 V |
| Input resistance of voltage input | > 10 kΩ |
Signal: Voltage/current
| Number of Outputs | 1 |
| Configurable/programmable | Yes |
| Voltage output signal | 0 V ... 5 V (via DIP switch) |
| Voltage output signal | 1 V ... 5 V (via DIP switch) |
| Voltage output signal | -5 V ... 5 V (via DIP switch) |
| Voltage output signal | 0 V ... 10 V (via DIP switch) |
| Voltage output signal | 2 V ... 10 V (via DIP switch) |
| Voltage output signal | -10 V ... 10 V (via DIP switch) |
| Non-load voltage | < 17 V |
| Current Output Signal | 0 mA ... 20 mA (via DIP switch) |
| Current Output Signal | 4 mA ... 20 mA (via DIP switch) |
| Max. current output signal | 22 mA |
| Short-circuit current | < 32 mA |
| Load/output load voltage output | ≥ 10 kΩ |
| Load/Output Load Current Output | ≤ 600 Ω (at 20 mA) |
| Ripple | < 20 mVPP (at 600 Ω) |
| Ripple | < 20 mVPP (at 600 Ω) |
Connection data
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
Ex data
| Ex installation (EPL) | Gc |
| Ex installation (EPL) | Div. 2 |
Signaling
| Status display | Green LED (supply voltage) |
Dimensions
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
Material specifications
| Color | gray (RAL 7042) |
| Housing Material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
| Degree of Protection | IP20 (not assessed by UL) |
| Ambient Temperature (Operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 3 G Ex ec ic IIC T4 Gc |
| Certificate | BVS 19 ATEX E 047 X |
UKCA Ex (UKEX)
| Identification | II 3 G Ex ec ic IIC T4 Gc |
| Certificate | PxCIF21UKEX2902000X |
IECEx
| Identification | Ex ec ic IIC T4 Gc |
| Certificate | IECEx BVS 19.0041X |
CCC / China-Ex
| Identification | Ex nA ic IIC T4 Gc |
UL, USA/Canada
| Identification | UL 508 Listed |
| Identification | Class I, Div. 2, Groups A, B, C, D T6 |
| Identification | Class I, Zone 2, Group IIC T6 |
Shipbuilding approval
| Certificate | DNV GL TAA00002UA |
EAC Ex
| Identification | 2Ex ec ic IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00079 |
DNV GL data
| Temperature | B |
| Humidity | B |
| Vibration | A |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
Fast transients (burst)
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
Conducted interference
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
Standards and Regulations
| Electrical isolation | 3-way isolation |
GB Standard
| Standards/regulations | GB 3836.1 |
| Standards/regulations | GB 3836.4 |
| Standards/regulations | GB 3836.8 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902021?
Proax is an authorized distributor of Phoenix Contact 2902021 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended