2924346
SKU
PHX2924346
MPN
MACX MCR-SL-TC-I-NC
Weight
0.163 kg
This product is Not Cancellable/Not Returnable
MACX MCR-SL-TC-I-NC - Temperature measuring transducer
Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4 - 20 mA analog signals. Freely programmable, 3-way electrical isolation, custom-configured. Replacement item: 1050228 MACX MCR-TC-I.
- Input for thermocouples and mV sources
- Power supply possible via DIN rail connector
- Installation in zone 2, protection type "n" (EN 60079-15) permitted
- Output: 0 mA ... 20 mA or 4 mA ... 20 mA
- Programming during operation and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
- Status indicator for supply voltage, cable, sensor, and module errors
- 3-way electrical isolation
- Configuration via software (FDT/DTM): sensor type, connection technology, measuring range, measuring unit, filter, alarm signal, and output range
Technical Specifications
Product properties
| Application | Temperature |
| No. of channels | 1 |
| Type | Signal conditioner |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Alignment span | ± 5 % |
| Alignment zero | ± 5 % |
| Electrical isolation | 3-way isolation |
| Typical cold point errors | ± 1 K |
| Step response (0–99%) | 700 ms |
| Step response (0–99%) | ≤ 1100 ms |
| Temperature coefficient, typical | 0.01 %/K |
Electrical isolation Input/output/power supply
| Rated Insulation Voltage | 300 Vrms |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Insulation | Safe isolation in accordance with IEC/EN 61010-1 |
Electrical isolation Input/output
| Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Electrical isolation Input/power supply
| Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Supply
| Nominal Supply Voltage | 24 V DC |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
| Max. current consumption | < 40 mA (24 V DC) |
| Power dissipation | < 1 W |
Signal
| Number of Inputs | 1 |
| Input Signal | Temperature |
| Input Signal | Voltage |
| Voltage input signal | -20 mV ... 70 mV |
Measurement
| Sensor types that can be used (TC) | E, J, K, N as per IEC / EN 60584, L as per DIN 43760 |
| Temperature measuring range | -250 °C ... 1372 °C (Range depending on the sensor type) |
| Sensor type: | -210 °C ... 1200 °C |
| Sensor type: | -200 °C ... 1372 °C |
| Sensor type: | -200 °C ... 1300 °C |
| Sensor type: | -226 °C ... 1000 °C |
| Sensor type: | -200 °C ... 900 °C |
| Linear mV signal range | -20 mV ... 70 mV |
| Temperature measuring range | Min. 50 K for thermocouples, 3 mV for mV sources |
Switching:
| Configurable/programmable | no |
Signal
| Output description | Current output |
| Number of Outputs | 1 |
| Configurable/programmable | Yes |
| Current Output Signal | 0 mA ... 20 mA |
| Current Output Signal | 4 mA ... 20 mA |
| Load/Output Load Current Output | max. 500 Ω |
| Output ripple (current) | < 50 µAPP |
| Output ripple (current) | < 10 µArms |
| Behavior in the event of a sensor error | As per NE 43 or can be freely defined |
Connection data
| Connection Method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
| Status display | Green LED (supply voltage, PWR) |
| Status display | Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR) |
| Status display | Red LED, flashing 1.2 Hz (service operation, ERR) |
| Status display | Red LED, permanently on (module error, ERR) |
Dimensions
| Width | 12.5 mm |
| Height | 106.4 mm |
| Depth | 114.5 mm |
Material specifications
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 (Housing) |
| Housing Material | PA 6.6-FR |
Ambient conditions
| Degree of Protection | IP20 (not assessed by UL) |
| Ambient Temperature (Operation) | -20 °C ... 60 °C (Any mounting position) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
| Note | and EN 61326-1 |
ATEX
| Identification | II 3G Ex nA ic IIC T4 Gc X |
UL, USA/Canada
| Identification | UL 508 Listed |
| Identification | UL 61010 Listed |
| Identification | Class I, Div. 2, Groups A, B, C, D T4 |
| Identification | Class I, Zone 2, Group IIC T4 |
Shipbuilding approval
| Certificate | GL 86 644-10HH |
GL
| Identification | C, EMC1 |
EMC data
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
Electromagnetic HF field
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
Fast transients (burst)
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
Conducted interference
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
Standards and Regulations
| Electrical isolation | 3-way isolation |
Mounting
| Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2924346?
Proax is an authorized distributor of Phoenix Contact 2924346 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended