Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MACX MCR-SL-TC-I-NC
Weight
0.163 kg
This product is Not Cancellable/Not Returnable

MACX MCR-SL-TC-I-NC - Temperature measuring transducer

Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4 - 20 mA analog signals. Freely programmable, 3-way electrical isolation, custom-configured. Replacement item: 1050228 MACX MCR-TC-I.

  • Input for thermocouples and mV sources
  • Power supply possible via DIN rail connector
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Output: 0 mA ... 20 mA or 4 mA ... 20 mA
  • Programming during operation and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
  • Status indicator for supply voltage, cable, sensor, and module errors
  • 3-way electrical isolation
  • Configuration via software (FDT/DTM): sensor type, connection technology, measuring range, measuring unit, filter, alarm signal, and output range
Technical Specifications

Product properties

ApplicationTemperature
No. of channels1
TypeSignal conditioner

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Alignment span± 5 %
Alignment zero± 5 %
Electrical isolation3-way isolation
Typical cold point errors± 1 K
Step response (0–99%)700 ms
Step response (0–99%)≤ 1100 ms
Temperature coefficient, typical0.01 %/K

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1

Electrical isolation Input/output

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Electrical isolation Input/power supply

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 40 mA (24 V DC)
Power dissipation< 1 W

Signal

Number of Inputs1
Input SignalTemperature
Input SignalVoltage
Voltage input signal-20 mV ... 70 mV

Measurement

Sensor types that can be used (TC)E, J, K, N as per IEC / EN 60584, L as per DIN 43760
Temperature measuring range-250 °C ... 1372 °C (Range depending on the sensor type)
Sensor type: -210 °C ... 1200 °C
Sensor type: -200 °C ... 1372 °C
Sensor type: -200 °C ... 1300 °C
Sensor type: -226 °C ... 1000 °C
Sensor type: -200 °C ... 900 °C
Linear mV signal range-20 mV ... 70 mV
Temperature measuring rangeMin. 50 K for thermocouples, 3 mV for mV sources

Switching:

Configurable/programmableno

Signal

Output descriptionCurrent output
Number of Outputs1
Configurable/programmableYes
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Load/Output Load Current Outputmax. 500 Ω
Output ripple (current)< 50 µAPP
Output ripple (current)< 10 µArms
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined

Connection data

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Signaling

Status displayGreen LED (supply voltage, PWR)
Status displayRed LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR)
Status displayRed LED, flashing 1.2 Hz (service operation, ERR)
Status displayRed LED, permanently on (module error, ERR)

Dimensions

Width12.5 mm
Height106.4 mm
Depth114.5 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant
Noteand EN 61326-1

ATEX

Identification II 3G Ex nA ic IIC T4 Gc X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationUL 61010 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T4
IdentificationClass I, Zone 2, Group IIC T4

Shipbuilding approval

CertificateGL 86 644-10HH

GL

IdentificationC, EMC1

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6

Standards and Regulations

Electrical isolation3-way isolation

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2924346?

Proax is an authorized distributor of Phoenix Contact 2924346 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1