SKU
MPN
MACX MCR-SL-RPSS-2I-2I-SP
Weight
0.245 kg
Series MACX-MCR-SL-RPSS
MACX MCR-SL-RPSS-2I-2I-SP - Repeater power supply
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, Push-in connection, SIL, PL.
Technical Specifications
Product properties
Product family | MACX Analog |
Application | Analog IN |
No. of channels | 2 |
Type | Signal conditioners with SIL and PL Functional Safety |
Electrical properties
Signal transmission behavior | In = Out |
Step response (10-90%) | < 1.3 ms (for 4 mA ... 20 mA step) |
Maximum temperature coefficient | < 0.01 %/K |
Maximum transmission error | < 0.1 % (of final value) |
Transmission error, typical | < 0.05 % (of final value) |
Electrical isolation
Overvoltage category | II |
Pollution degree | 2 |
Electrical isolation Input/output, power supply IEC/EN 61010-1
Standards/regulations | IEC/EN 61010-1 |
Rated Insulation Voltage | 300 Vrms |
Test voltage | 2.5 kV AC (50 Hz, 60 s) |
Insulation | Safe isolation |
Electrical isolation Output 1/output 2/ power supply
Test voltage | 1.5 kV AC (50 Hz, 60 s) |
Supply
Nominal Supply Voltage | 24 V DC -20 % ... +25 % |
Supply Voltage Range | 19.2 V DC ... 30 V DC |
Max. current consumption | < 100 mA (24 V DC / 20 mA) |
Power dissipation | < 1.4 W (24 V DC / 20 mA) |
Power consumption | ≤ 2.4 W |
Signal: Current
Number of Inputs | 2 |
Current Input Signal | 4 mA ... 20 mA |
Transmitter supply voltage | > 16 V (20 mA) |
Underload/overload signal range | 0 mA ... 24 mA |
Signal
Output description | Current output |
Number of Outputs | 2 |
Current Output Signal | 4 mA ... 20 mA (active) |
Load/Output Load Current Output | ≤ 450 Ω (20 mA) |
Load/Output Load Current Output | ≤ 375 Ω (24 mA) |
Output behavior in the event of an error | < 3.6 mA (In the event of cable break at the input (as per NE 43)) |
Output behavior in the event of an error | > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) |
Underload/overload signal range | 0 mA ... 24 mA |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible (2 conductors with same cross section) | 0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve) |
Conductor cross section flexible (2 conductors with same cross section) | 0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve) |
Conductor cross section AWG | 24 ... 14 |
Conductor cross section AWG | 24 ... 22 (TWIN ferrule without plastic sleeve) |
Conductor cross section AWG | 20 ... 16 (TWIN ferrule with plastic sleeve) |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Data communication (bypass)
HART Function | Yes |
Protocols Supported | HART-transparent |
Signaling
Status display | Green LED (supply voltage) |
Dimensions
Width | 12.5 mm |
Height | 107.9 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Housing Material | PA 6.6-FR |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 60 °C (Any mounting position) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Derating) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Altitude range (≤ 2000 m)
Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Ambient Temperature (Operation) | -40 °C ... 60 °C |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Derating) |
Rated Insulation Voltage | 375 VPP (Power supply, input / output) |
Altitude range (≤ 3000 m)
Height Range | > 2000 m ... 3000 m |
Ambient Temperature (Operation) | -40 °C ... 54 °C |
Ambient Temperature (Operation) | -40 °C ... 63 °C (Derating) |
Rated Insulation Voltage | 190 V AC (Power supply, input / output) |
Rated Insulation Voltage | 110 V DC (Power supply, input / output) |
Altitude range (≤ 4000 m)
Height Range | > 3000 m ... 4000 m |
Ambient Temperature (Operation) | -40 °C ... 48 °C |
Ambient Temperature (Operation) | -40 °C ... 56 °C (Derating) |
Rated Insulation Voltage | 60 V AC/DC (Power supply, input / output) |
Altitude range (≤ 5000 m)
Height Range | > 4000 m ... 5000 m |
Ambient Temperature (Operation) | -40 °C ... 42 °C |
Ambient Temperature (Operation) | -40 °C ... 49 °C (Derating) |
Rated Insulation Voltage | 60 V AC/DC (Power supply, input / output) |
CE
Certificate | CE-compliant |
Note | and EN 61326 |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc X |
Certificate | PxCIF11ATEX2924825X |
UKCA Ex (UKEX)
Identification | II 3 G Ex nA IIC T4 Gc |
Certificate | PxCIF21UKEX2904089X |
IECEx
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx BVS 10.0097X |
CCC / China-Ex
Identification | Ex ec IIC T4 Gc |
Certificate | 2022122316115972 |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | UL 61010 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Identification | Class I, Zone 2, Groups IIC, IIB, IIA T4 |
Identification | UL 61010 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Identification | Class I, Zone 2, Group IIC T4 |
Shipbuilding approval
Certificate | DNV GL TAA000020C |
Safety Integrity Level (SIL, IEC 61508)
Identification | 3 |
Certificate | BVS PB 04-13 |
Performance Level (ISO 13849)
Identification | d |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2904090?
Proax is an authorized distributor of Phoenix Contact 2904090 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended