MACX MCR-SL-UI-REL-SP - Limit value switch

Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.

Technical Specifications

Product properties

Product familyMACX Analog
TypeSignal conditioners with SIL and PL Functional Safety
ConfigurationDIP switches

Insulation characteristics: GB Standard

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches

Electrical properties

Electrical isolation3-way isolation
Switching point accuracy< 0.1 %
Step response (0–99%)≤ 22 ms
Maximum temperature coefficient0.01 %/K
Maximum transmission error0.1 %

Electrical isolation Output/supply

Rated Insulation Voltage250 V AC (IEC/EN 60079-7)

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 V AC (EN 61010-1)
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1

Electrical isolation Input/output, power supply

Rated Insulation Voltage375 V AC (IEC/EN 60079-7)

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range9.6 V DC ... 30 V DC (12 V DC ... 24 V DC (-20 % ... +25 %))
Typical current consumption38 mA (24 V DC)
Max. current consumption90 mA (10 V DC)
Power dissipation< 0.9 W
Power consumption≤ 1.2 W

Signal: Voltage/current

Voltage input signal0.1 V ... 10 V
Voltage input signal0.1 V ... 10.5 V (Maximum range)
Total error of the voltage input maximum± 10 mV
Current Input Signal0.2 mA ... 20 mA
Current Input Signal0.18 mA ... 21 mA (Maximum range)
Total error of the current input maximum± 20 µA
Input resistance of voltage input> 100 kΩ
Input resistance current input< 28 Ω
Switching threshold "0" signal currentConfigurable via DIP switch (in 1.25% increments) and potentiometer (linearly up to  2% of the switching threshold set via the DIP switch)
Switching hysteresisoff: approx. 0.5 %, on: approx. 1 %
Line fault detection< 0.1 mA (Line break)
Line fault detection> 21.1 mA (Short circuit)

Switching: Relay

Contact switching type1 changeover contact
Contact MaterialAgSnO2, hard gold-plated
Max. switching current≤ 4 A AC (cos phi = 1)
Max. switching current≤ 1 A DC (ohmic load, 24 V DC, 50 mW)
Max. switching current≤ 0.2 A DC (ohmic load, 120 V DC)

Connection data

Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Test socket

Max. diameter2 mm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Signaling

Status displayGreen LED (supply voltage)
Status displayYellow LED (switching output)
Status displayRed LED, flashing (line, sensor error, ERR)

Dimensions

Width12.5 mm
Height116 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification II 3G Ex ec nC IIC T4 Gc
CertificateTÜV 18 ATEX 8222 X

UKCA Ex (UKEX)

Identification II 3 G Ex ec nC IIC T4 Gc
CertificatePxCIF21UKEX2906169X

IECEx

IdentificationEx ec nC IIC T4 Gc
CertificateIECEx TUR 18.0014X

CCC / China-Ex

IdentificationEx ec nC IIC T4 Gc
Certificate2022122304115959

INMETRO

IdentificationEx ec nC IIC T4 Gc
CertificateDNV 21.0089 X

UL, USA/Canada

IdentificationUL 61010 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T4
IdentificationClass I, Zone 2, Group IIC T4

Shipbuilding approval

CertificateDNV GL TAA000020C

EAC

Identification2Ex e nC IIC T4 Gc X
CertificateRU C-DE.HB49.B.00145/21

Safety Integrity Level (SIL, IEC 61508)

Identification2
CertificateTÜV Rheinland 968/FSP 1481.01/23
NoteSingle-channel
Identification3
CertificateTÜV Rheinland 968/FSP 1481.01/23
NoteTwo-channel

Systematic Capability

Identification3

Performance Level (ISO 13849)

Identificationc
TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Electromagnetic compatibilityConformance with EMC directive
Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Noise emissionEN 61000-6-4

Standards and Regulations

Electrical isolation3-way isolation

GB Standard

Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.3
Standards/regulationsGB 3836.8

Mounting

Mounting TypeDIN rail mounting

Why Proax for Phoenix Contact 2906170?

Proax is an authorized distributor of Phoenix Contact 2906170 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability