MACX MCR-SL-RPSSI-I-UP-SP - Repeater power supply
Repeater power supply for supplying 2- and 4-conductor transmitters with HART transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), Push-in connection
- 250 Ω resistor that can be activated via DIP switches to increase HART impedance for low-resistance systems
- Up to SIL 2 in accordance with EN 61508
- Installation in zone 2, protection type "n" (EN 60079-15) permitted
- Wide-range power supply of 19.2 ... 253 V AC/DC
- 3-way electrical isolation
- Plug-in screw or spring-cage connection technology (Push-in technology), with integrated sockets for HART communicators
- Input: 0/4 mA ... 20 mA (powered or not powered)
- Bidirectional transmission of digital HART communication signals
- 0/4 ... 20 mA output (active or passive), 0/1 ... 5 V, can be selected via DIP switches
Technical Specifications
Product properties
Product family | MACX Analog |
Application | Analog IN |
No. of channels | 1 |
Type | Signal conditioners with SIL functional safety |
Configuration | DIP switches |
Electrical properties
Electrical isolation | 3-way isolation |
Electrical isolation between input and output | yes |
Signal transmission behavior | In = Out |
Step response (10-90%) | < 600 µs (for 4 mA ... 20 mA step) |
Maximum temperature coefficient | < 0.01 %/K |
Maximum transmission error | < 0.1 % (of final value) |
Transmission error, typical | < 0.05 % (of final value) |
Electrical isolation
Test voltage | 2.5 kV AC (50 Hz, 60 s) |
Overvoltage category | II |
Pollution degree | 2 |
Electrical isolation Input/output/power supply IEC/EN 61010-1
Standards/regulations | IEC/EN 61010-1 |
Rated Insulation Voltage | 300 Vrms |
Insulation | Safe isolation |
Supply
Designation | Repeater power supply operation |
Nominal supply voltage range | 24 V AC/DC ... 230 V AC/DC -20 % ... +10 % (50/60 Hz) |
Supply Voltage Range | 19.2 V AC/DC ... 253 V AC/DC (50/60 Hz) |
Max. current consumption | < 75 mA (24 V DC / 20 mA) |
Power dissipation | < 1.6 W (24 V DC / 20 mA) |
Power consumption | < 1.9 W |
Designation | Signal conditioner operation |
Nominal supply voltage range | 24 V AC/DC ... 230 V AC/DC -20 % ... +10 % (50/60 Hz) |
Supply Voltage Range | 19.2 V AC/DC ... 253 V AC/DC (50/60 Hz) |
Max. current consumption | < 45 mA (24 V DC / 20 mA) |
Power dissipation | < 1.1 W (24 V DC / 20 mA) |
Power consumption | < 1.1 W |
Signal: Repeater power supply operation
Description of the input | Active current input |
Number of Inputs | 1 |
Current Input Signal | 4 mA ... 20 mA |
Transmitter supply voltage | > 16 V (20 mA) |
Transmitter supply voltage | > 15.3 V (22.5 mA) |
Signal: Signal conditioner operation
Description of the input | Passive current input |
Current Input Signal | 0 mA ... 20 mA |
Current Input Signal | 4 mA ... 20 mA |
Voltage drop | < 3.5 V (in input isolating amplifier operation) |
Signal: Repeater power supply operation
Output description | Current output (active and passive) |
Number of Outputs | 1 |
Voltage output signal | 1 V ... 5 V (internal resistance, 250 Ω, 0.1%) |
Voltage output signal | Configurable via DIP switches |
Current Output Signal | 4 mA ... 20 mA (active) |
Current Output Signal | 4 mA ... 20 mA (14 ... 26 V ext. source voltage) |
Load/Output Load Current Output | < 600 Ω (20 mA) |
Load/Output Load Current Output | < 525 Ω (22.5 mA) |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
Output behavior in the event of an error | ≥ 22.5 mA (Cable short-circuit in the input) |
Signal: Signal conditioner operation
Output description | Current output (active and passive) |
Voltage output signal | 0 V ... 5 V (internal resistance, 250 Ω, 0.1%) |
Voltage output signal | 1 V ... 5 V (internal resistance, 250 Ω, 0.1%) |
Current Output Signal | 0 mA ... 20 mA (active) |
Current Output Signal | 4 mA ... 20 mA (active) |
Current Output Signal | 0 mA ... 20 mA (14 ... 26 V ext. source voltage) |
Current Output Signal | 4 mA ... 20 mA (14 ... 26 V ext. source voltage) |
Load/Output Load Current Output | < 600 Ω (20 mA) |
Load/Output Load Current Output | < 525 Ω (22.5 mA) |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
Output behavior in the event of an error | 0 mA (Cable short-circuit in the input) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible (2 conductors with same cross section) | 0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve) |
Conductor cross section flexible (2 conductors with same cross section) | 0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve) |
Conductor cross section AWG | 24 ... 14 |
Conductor cross section AWG | 24 ... 22 (TWIN ferrule without plastic sleeve) |
Conductor cross section AWG | 20 ... 16 (TWIN ferrule with plastic sleeve) |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Data communication (bypass)
HART Function | Yes |
Protocols Supported | HART-transparent |
Signaling
Status display | Green LED (supply voltage) |
Dimensions
Width | 17.5 mm |
Height | 107.9 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Housing Material | PA 6.6-FR |
Ambient conditions
Degree of Protection | IP20 (not assessed by UL) |
Ambient Temperature (Operation) | -40 °C ... 60 °C (Any mounting position) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Derating) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Altitude range (≤ 2000 m)
Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Ambient Temperature (Operation) | -40 °C ... 60 °C |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Derating) |
Rated Insulation Voltage | 375 VPP (Power supply, input / output) |
Altitude range (≤ 3000 m)
Height Range | > 2000 m ... 3000 m |
Ambient Temperature (Operation) | -40 °C ... 54 °C |
Ambient Temperature (Operation) | -40 °C ... 63 °C (Derating) |
Rated Insulation Voltage | 190 V AC (Power supply, input / output) |
Rated Insulation Voltage | 110 V DC (Power supply, input / output) |
Altitude range (≤ 4000 m)
Height Range | > 3000 m ... 4000 m |
Ambient Temperature (Operation) | -40 °C ... 48 °C |
Ambient Temperature (Operation) | -40 °C ... 56 °C (Derating) |
Rated Insulation Voltage | 60 V AC/DC (Power supply, input / output) |
Altitude range (≤ 5000 m)
Height Range | > 4000 m ... 5000 m |
Ambient Temperature (Operation) | -40 °C ... 42 °C |
Ambient Temperature (Operation) | -40 °C ... 49 °C (Derating) |
Rated Insulation Voltage | 60 V AC/DC (Power supply, input / output) |
CE
Certificate | CE-compliant |
Note | and EN 61326-1 |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc X |
Certificate | PxCIF08ATEX2865968X |
UKCA Ex (UKEX)
Identification | II 3 G Ex nA IIC T4 Gc |
Certificate | PxCIF21UKEX2865968X |
IECEx
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx BVS 08.0035X |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | UL 61010 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Identification | Class I, Zone 2, Group IIC T4 |
Safety Integrity Level (SIL / SILCL, IEC 61508)
Identification | 2 |
Certificate | ZP/C031/20 |
Systematic Capability (SC / SILCL)
Identification | 3 |
EMC data
Noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Standards and Regulations
Electrical isolation | 3-way isolation |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2924210?
Proax is an authorized distributor of Phoenix Contact 2924210 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended