Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSI-MOS-RS422/FO 850 E
Weight
0.254 kg
This product is Not Cancellable/Not Returnable
Series PSI-MOS-RS

PSI-MOS-RS422/FO 850 E - FO converters

FO converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4-wire/INTERBUS up to 2 Mbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)

  • Supply voltage routed through via DIN rail connectors
  • Connections can be plugged in via a COMBICON screw terminal block
  • Redundant power supply possible by means of optional system power supply unit
  • High-quality electrical isolation between all interfaces (INTERBUS // FO ports // supply // DIN rail connector)
  • Approved for use in zone 2
  • Floating switch contact for advance warning of critical FO paths
  • Integrated optical diagnostics for continuous monitoring of FO paths
  • Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
  • Automatic data rate detection for all data rates up to 2 Mbps
  • Shipbuilding approval in accordance with DNV GL
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF1024 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF442 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF183 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF320 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
MTBF48 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))

Electrical properties

Electrical isolationVCC // RS-422
Maximum power dissipation for nominal condition2.88 W
Test voltage data interface/power supply1.5 kVrms (50 Hz, 1 min.)

Supply

Supply Voltage Range18 V DC ... 30 V DC
Nominal Supply Voltage24 V DC (in acc. with UL)
Typical current consumption120 mA (24 V DC)
Max. current consumption130 mA
Max. current consumption≤ 2 A (For operation in a joining station, via the DIN rail connector)

Switching

Output nameRelay output
Output descriptionAlarm output
Number of Outputs1
Maximum Switching Voltage60 V DC
Maximum Switching Voltage42 V AC
Limiting Continuous Current0.46 A

Supply

Connection MethodCOMBICON plug-in screw terminal block
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces

Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
SignalINTERBUS
Transmission channels2 (1/1) RD, TD, full duplex

Data: optical FO

No. of channels1
Transmit capacity, minimum-4.6 dBm (200/230 µm)
Transmit capacity, minimum-17.6 dBm (50/125 µm)
Transmit capacity, minimum-13.6 dBm (62,5/125 µm)
Transmission length incl. 3 dB system reserve2800 m (F-K 200/230 8 dB/km with quick mounting connector)
Transmission length incl. 3 dB system reserve4200 m (with F-G 50/125 2.5 dB/km)
Transmission length incl. 3 dB system reserve4800 m (with F-G 62,5/125 3.0 dB/km)
Transmission protocolTransparent to protocol for RS-422 interface
Connection MethodB-FOC (ST®)
Wavelength850 nm
Minimum receiver sensitivity-33.2 dBm
Transmission mediumPCF fiber
Transmission mediumMulti-mode fiberglass

Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1

Serial transmission speed≤ 2 Mbps
Connection MethodPluggable screw connection
Transmission length≤ 1000 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor220 Ω
Termination resistor100 Ω
Termination resistor220 Ω
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Transmission mediumCopper
File format/codingUART (11 Bit, NRZ)

Dimensions

Width35 mm
Height99 mm
Depth103 mm

Material specifications

Color (Housing)green (RAL 6021)
Material (Housing)PA 6.6-FR

FO cable

Fiber types200/230 µm
Fiber types50/125 µm
Fiber types62.5/125 µm
Fiber typesPCF fiber
Fiber typesFiberglass

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)30 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex nA nC IIC T4 Gc X
NotePlease follow the special installation instructions in the documentation!

ATEX, FO interface

Identification II (2) G [Ex op is Gb] IIC
Identification II (2) D [Ex op is Db] IIIC
CertificatePTB 06 ATEX 2042 U
NotePlease follow the special installation instructions in the documentation!

UL, USA/Canada

IdentificationClass I, Zone 2, AEx nc IIC T5
IdentificationClass I, Zone 2, Ex nC nL IIC T5 X
IdentificationClass I, Div. 2, Groups A, B, C, D

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

Shipbuilding

IdentificationDNV GL

DNV GL data

TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2:2005
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV
Signal± 2 kV
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV
Signal± 1 kV
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
CommentsCriterion A
Voltage10 V

Emitted interference

Standards/regulationsEN 55011
CommentsClass A, industrial applications

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2708355?

Proax is an authorized distributor of Phoenix Contact 2708355 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability