2708575
SKU
PHX2708575
MPN
PSI-MOS-RS422/FO1300 E
Weight
0.254 kg
Series PSI-MOS-RS
PSI-MOS-RS422/FO1300 E - FO converters
Fiber optic converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4 wire/ INTERBUS up to 2 Mbps, termination device with one fiber optic interface (SC duplex), 1300 nm, for fiberglass cable
- Connections can be plugged in via a COMBICON screw terminal block
- Supply voltage routed through via DIN rail connectors
- Redundant power supply possible by means of optional system power supply unit
- High-quality electrical isolation between all interfaces (INTERBUS // FO ports // supply // DIN rail connector)
- Approved for use in zone 2
- Floating switch contact for advance warning of critical FO paths
- Integrated optical diagnostics for continuous monitoring of FO paths
- Automatic data rate detection for all data rates up to 2 Mbps
- Shipbuilding approval in accordance with DNV GL
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area | 
| CCCex note | Use in potentially explosive areas is not permitted in China. | 
Product properties
| MTTF | 891 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) | 
| MTTF | 397 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | 
| MTTF | 164 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | 
| MTBF | 544 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) | 
| MTBF | 113 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | 
Electrical properties
| Electrical isolation | VCC // RS-422 | 
| Maximum power dissipation for nominal condition | 2.75 W | 
| Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) | 
Supply
| Supply Voltage Range | 18 V DC ... 32 V DC | 
| Nominal Supply Voltage | 24 V DC (in acc. with UL) | 
| Typical current consumption | 110 mA (24 V DC) | 
| Max. current consumption | ≤ 2 A (For operation in a joining station, via the DIN rail connector) | 
Switching
| Output name | Relay output | 
| Output description | Alarm output | 
| Number of Outputs | 1 | 
| Maximum Switching Voltage | 60 V DC | 
| Maximum Switching Voltage | 42 V AC | 
| Limiting Continuous Current | 1 A | 
Supply
| Connection Method | COMBICON plug-in screw terminal block | 
| Tightening torque | 0.56 Nm ... 0.79 Nm | 
Interfaces
| Bit distortion, input | ± 35 % (permitted) | 
| Bit distortion, output | < 6.25 % | 
| Signal | INTERBUS | 
| Transmission channels | 2 (1/1) RD, TD, full duplex | 
Data: optical FO
| No. of channels | 1 | 
| Transmit capacity, minimum | -3.4 dBm (50/125 μm, multimode fiberglass) | 
| Transmit capacity, minimum | -4.7 dBm (62.5/125 μm, multimode fiberglass) | 
| Transmit capacity, minimum | -5.5 dBm (9/125 μm, singlemode fiberglass) | 
| Transmission length incl. 3 dB system reserve | 27 km (With F-G 50/125 0.7 dB/km at 1300 nm) | 
| Transmission length incl. 3 dB system reserve | 22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm) | 
| Transmission length incl. 3 dB system reserve | 45 km (With F-E 9/125 0,4 dB/km at 1300 nm) | 
| Transmission protocol | Transparent to protocol for RS-422 interface | 
| Connection Method | SC duplex | 
| Wavelength | 1300 nm | 
| Minimum receiver sensitivity | -25.5 dBm (50/125 µm) | 
| Minimum receiver sensitivity | -25.5 dBm (62,5/125 µm) | 
| Minimum receiver sensitivity | -26.5 dBm (9/125 µm) | 
| Maximum receiver sensitivity | 0 dBm | 
| Transmission medium | Multi-mode fiberglass | 
| Transmission medium | Single-mode fiberglass | 
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
| Serial transmission speed | ≤ 2 Mbps | 
| Connection Method | Pluggable screw connection | 
| Transmission length | ≤ 1000 m (depending on the data rate, with shielded, twisted data cable) | 
| Termination resistor | 220 Ω | 
| Termination resistor | 100 Ω | 
| Termination resistor | 220 Ω | 
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² | 
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² | 
| Max. AWG conductor cross section, flexible | 14 | 
| Min. AWG conductor cross section, flexible | 24 | 
| Single-wire/terminal point, rigid AWG max. | 14 | 
| Single-wire/terminal point, rigid AWG min. | 24 | 
| Transmission medium | Copper | 
| File format/coding | UART (11 Bit, NRZ) | 
Dimensions
| Width | 35 mm | 
| Height | 105 mm | 
| Depth | 103 mm | 
Material specifications
| Color (Housing) | green (RAL 6021) | 
| Material (Housing) | PA 6.6-FR | 
FO cable
| Fiber types | 50/125 µm | 
| Fiber types | 9/125 µm | 
| Fiber types | Fiberglass | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -20 °C ... 60 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) | 
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) | 
CE
| Certificate | CE-compliant | 
ATEX
| Identification |  II 3 G Ex nA nC IIC T4 Gc X | 
| Note | Please follow the special installation instructions in the documentation! | 
UL, USA/Canada
| Identification | 508 Listed | 
| Identification | 508 Recognized | 
KC approval for South Korea
| Certificate | MSIP-REI-PCK-2708575 | 
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A | 
Shipbuilding
| Identification | DNV GL | 
DNV GL data
| Temperature | B | 
| Humidity | A | 
| Vibration | A | 
| EMC | B | 
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | 
EMC data
| Noise immunity | EN 61000-6-2:2005 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Noise emission | EN 55011 | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Contact discharge | ± 6 kV | 
| Discharge in air | ± 8 kV | 
| Comments | Criterion B | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Field intensity | 10 V/m | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Input | ± 2 kV | 
| Signal | ± 2 kV | 
| Comments | Criterion B | 
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 | 
| Input | ± 0.5 kV | 
| Signal | ± 1 kV | 
| Comments | Criterion B | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Emitted interference
| Standards/regulations | EN 55011 | 
| Comments | Class A, industrial applications | 
Criteria
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
Standards and Regulations
| Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 | 
Mounting
| Mounting Type | DIN rail mounting | 
Accessories
Why Proax for Phoenix Contact 2708575?
Proax is an authorized distributor of Phoenix Contact 2708575 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 
Recommended