Official Distributor
SKU
MPN
PSI-MOS-RS422/FO 660 E
Weight
0.245 kg
This product is Not Cancellable/Not Returnable
Series PSI-MOS-RS
PSI-MOS-RS422/FO 660 E - FO converters
FO converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4-wire/INTERBUS up to 2 Mbps, terminal device with one FO interface (FSMA), 660 nm, for polymer/PCF fiber cable
- Supply voltage routed through via DIN rail connectors
- Connections can be plugged in via a COMBICON screw terminal block
- Redundant power supply possible by means of optional system power supply unit
- High-quality electrical isolation between all interfaces (INTERBUS // FO ports // supply // DIN rail connector)
- Approved for use in zone 2
- Floating switch contact for advance warning of critical FO paths
- Integrated optical diagnostics for continuous monitoring of FO paths
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Automatic data rate detection for all data rates up to 2 Mbps
- Shipbuilding approval in accordance with DNV GL
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
MTTF | 1025 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 442 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 184 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
MTBF | 493 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
MTBF | 92 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Electrical properties
Electrical isolation | VCC // RS-422 |
Maximum power dissipation for nominal condition | 2.4 W |
Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 18 V DC ... 30 V DC |
Nominal Supply Voltage | 24 V DC (in acc. with UL) |
Typical current consumption | 100 mA (24 V DC) |
Max. current consumption | 130 mA |
Max. current consumption | ≤ 2 A (For operation in a joining station, via the DIN rail connector) |
Switching
Output name | Relay output |
Output description | Alarm output |
Number of Outputs | 1 |
Maximum Switching Voltage | 60 V DC |
Maximum Switching Voltage | 42 V AC |
Limiting Continuous Current | 0.46 A |
Supply
Connection Method | COMBICON plug-in screw terminal block |
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Bit distortion, input | ± 35 % (permitted) |
Bit distortion, output | < 6.25 % |
Signal | INTERBUS |
Transmission channels | 2 (1/1) RD, TD, full duplex |
Data: optical FO
No. of channels | 1 |
Transmit capacity, minimum | -4.6 dBm (980/1000 µm) |
Transmit capacity, minimum | -16.6 dBm (200/230 µm) |
Transmission length incl. 3 dB system reserve | 100 m (F-P 980/1000 230 dB/km with quick mounting connector) |
Transmission length incl. 3 dB system reserve | 800 m (F-K 200/230 10 dB/km with quick mounting connector) |
Transmission protocol | Transparent to protocol for RS-422 interface |
Connection Method | F-SMA |
Wavelength | 660 nm |
Minimum receiver sensitivity | -31.2 dBm |
Transmission medium | Polymer fiber |
Transmission medium | PCF fiber |
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Serial transmission speed | ≤ 2 Mbps |
Connection Method | Pluggable screw connection |
Transmission length | ≤ 1000 m (depending on the data rate, with shielded, twisted data cable) |
Termination resistor | 220 Ω |
Termination resistor | 100 Ω |
Termination resistor | 220 Ω |
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Max. AWG conductor cross section, flexible | 14 |
Min. AWG conductor cross section, flexible | 24 |
Single-wire/terminal point, rigid AWG max. | 14 |
Single-wire/terminal point, rigid AWG min. | 24 |
Transmission medium | Copper |
File format/coding | UART (11 Bit, NRZ) |
Dimensions
Width | 35 mm |
Height | 99 mm |
Depth | 103 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
FO cable
Fiber types | 980/1000 µm |
Fiber types | 200/230 µm |
Fiber types | Polymer fiber |
Fiber types | PCF fiber |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
ATEX, FO interface
Identification | II (2) G [Ex op is Gb] IIC |
Identification | II (2) D [Ex op is Db] IIIC |
Certificate | PTB 06 ATEX 2042 U |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | Class I, Zone 2, AEx nc IIC T5 |
Identification | Class I, Zone 2, Ex nC nL IIC T5 X |
Identification | Class I, Div. 2, Groups A, B, C, D |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Shipbuilding
Identification | DNV GL |
DNV GL data
Temperature | B |
Humidity | A |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2:2005 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV |
Signal | ± 2 kV |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV |
Signal | ± 1 kV |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55011 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2708342?
Proax is an authorized distributor of Phoenix Contact 2708342 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended