Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSI-MOS-PROFIB/FO1300 E
Weight
0.234 kg
This product is Not Cancellable/Not Returnable

PSI-MOS-PROFIB/FO1300 E - FO converters

Fiber optic converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, termination device with one fiber optic interface (SC-Duplex), 1300 nm, for fiberglass cable

  • Connections can be plugged in via a COMBICON screw terminal block
  • Supply voltage and data signals routed through the DIN rail connectors
  • Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
  • Automatic data rate detection or fixed data rate setting via DIP switches
  • Redundant power supply possible by means of optional system power supply unit
  • High-quality electrical isolation between all interfaces (PROFIBUS // fiber optic ports // power supply // DIN rail connector)
  • Approved for use in zone 2
  • Floating switch contact for advance warning of critical FO paths
  • Integrated optical diagnostics for continuous monitoring of FO paths
  • Bit retiming for any cascading depth
  • Suitable for all data rates up to 12 Mbps
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties

MTTF849 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF392 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF163 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF406 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
MTBF92 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))

Electrical properties

Electrical isolationVCC // RS-485
Maximum power dissipation for nominal condition1.32 W
Test voltage data interface/power supply1.5 kVrms (50 Hz, 1 min.)

Supply

Supply Voltage Range18 V DC ... 32 V DC (via pluggable COMBICON screw terminal block)
Nominal Supply Voltage24 V DC (in acc. with UL)
Typical current consumption55 mA (24 V DC)
Max. current consumption90 mA
Max. current consumption≤ 2 A (For operation in a joining station, via the DIN rail connector)

Switching

Output nameRelay output
Output descriptionAlarm output
Number of Outputs1
Maximum Switching Voltage60 V DC (Resistive Load, General Load)
Maximum Switching Voltage30 V AC (Resistive load)
Maximum Switching Voltage42 V AC (peak, resistive load)
Limiting Continuous Current0.46 A

Supply

Connection MethodCOMBICON plug-in screw terminal block
Stripping length7.00 mm
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces

Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
Bit delay< 1 bit (DIP 7 = OFF, standard operation)
Bit delay11 bit (DIP 7 = ON, redundancy operation)
SignalPROFIBUS

Data: optical FO

No. of channels1
Transmit capacity, minimum-3.4 dBm (50/125 μm, multimode fiberglass)
Transmit capacity, minimum-4.7 dBm (62.5/125 μm, multimode fiberglass)
Transmit capacity, minimum-5.5 dBm (9/125 μm, singlemode fiberglass)
Transmission length incl. 3 dB system reserve25 km (With F-G 50/125 0.7 dB/km at 1300 nm)
Transmission length incl. 3 dB system reserve22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm)
Transmission length incl. 3 dB system reserve45 km (With F-E 9/125 0,4 dB/km at 1300 nm)
Transmission protocolProtocol-transparent to the RS-485 interface
Connection MethodSC duplex
Wavelength1300 nm
Minimum receiver sensitivity-25.5 dBm (Multi mode)
Minimum receiver sensitivity-26.5 dBm (Singlemode)
Maximum receiver sensitivity0 dBm
Transmission mediumMulti-mode fiberglass
Transmission mediumSingle-mode fiberglass

Data: PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control

Serial transmission speed≤ 12 Mbps
Connection MethodD-SUB-9 female connector
Transmission length≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Transmission medium2-wire twisted pair, shielded
File format/codingUART (11 Bit, NRZ)
Data direction switchingAutomatic control
Output nominal voltage5 V DC ±0.25 (50 mA)

Dimensions

Width35 mm
Height105 mm
Depth106 mm

Material specifications

Color (Housing)gray (RAL 7042)
Material (Housing)PA 6.6-FR

FO cable

Fiber types50/125 µm
Fiber types62.5/125 µm
Fiber types9/125 µm
Fiber typesFiberglass

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Altitude≤ 2000 m (Hazardous locations)
Permissible humidity (operation)30 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateUL 21 ATEX 2550X
NotePlease follow the special installation instructions in the documentation!

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 21.00013X

UL, USA/Canada

IdentificationClass I, Zone 2, AEx ec IIC T4 Gc
IdentificationEx ec IIC T4 Gc X
IdentificationClass I, Div. 2, Groups A, B, C, D

Corrosive gas test

IdentificationISA-S71.04-1985 G3 Harsh Group A

EMC data

Noise immunityEN 61000-6-2:2005
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Discharge in air± 8 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Field intensity10 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input± 2 kV
Signal± 2 kV
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
Input± 0.5 kV
Signal± 1 kV
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
CommentsCriterion A
Voltage10 V

Emitted interference

Standards/regulationsEN 55011
CommentsClass A, industrial applications

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and Regulations

Free from substances that could impair the application of coatingin accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2708559?

Proax is an authorized distributor of Phoenix Contact 2708559 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability