PSI-TERMINATOR-PB-TBUS - Termination resistor
Active termination resistor for PROFIBUS and RS-485 bus systems, redundant power supply, routing of the supply voltage via DIN rail connector, electrical isolation, switchable termination, integrated programming interface
- Diagnostic LEDs for voltage and data activity
- Interference-free bus communication thanks to active termination
- Compact housing design
- Fixed programming interface in the network
- Termination can be connected externally
- Installation as single device or in combination with other devices
- Extended temperature range of -40 °C … +70 °C
- Electrical isolation of power supply and data interface
- Redundant power supply
- Supply voltage routed through a DIN rail connector for use in combination with other devices
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
MTTF | 3305 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 1923 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 911 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Electrical isolation | RS-485 // VCC |
Maximum power dissipation for nominal condition | 0.24 W |
Test voltage data interface/power supply | 1.5 kV AC (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Nominal Supply Voltage | 24 V DC (via pluggable COMBICON screw terminal block) |
Typical current consumption | 10 mA (24 V DC, no load on D-SUB) |
Typical current consumption | 60 mA (24 V DC, current drain at D-SUB of 150 mA) |
Max. current consumption | 12 mA (18 V DC, no load on D-SUB) |
Max. current consumption | 77 mA (18 V DC, current drain at D-SUB of 150 mA) |
Function
Status and diagnostic indicators | LEDs: US (power supply), ACT (data activity) |
Supply
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible [AWG] | 24 ... 12 |
Tightening torque | 0.6 Nm ... 0.8 Nm |
Interfaces
Signal | Modbus |
Signal | PROFIBUS |
Data: PROFIBUS acc. to IEC 61158, RS-485 2-conductor
Serial transmission speed | ≤ 12 Mbps |
Connection Method | D-SUB-9, COMBICON |
Transmission length | ≤ 1200 m (Depends on transmission speed and cable type) |
Termination resistor | 390 Ω |
Termination resistor | 220 Ω |
Termination resistor | 390 Ω (Can be connected) |
Single conductor/terminal point, rigid | 0.2 mm² ... 1.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 1.5 mm² |
Max. AWG conductor cross section, flexible | 16 |
Min. AWG conductor cross section, flexible | 24 |
Single-wire/terminal point, rigid AWG max. | 16 |
Single-wire/terminal point, rigid AWG min. | 24 |
Output nominal voltage | 5 V DC |
Dimensions
Width | 22.5 mm |
Height | 92 mm |
Depth | 73 mm |
Material specifications
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Altitude | ≤ 2000 m (Restrictions for ATEX applications) |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Air pressure (operation) | ≤ 80 kPa (When used in EX zone 2) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex nA IIC T4 Gc X |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | 508 Listed |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2.2 kV (Test Level 3) |
Signal | ± 2.2 kV (Test Level 3) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (sym./asym.) |
Signal | ± 1 kV (Data line, asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55011 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
- 2707437 - DIN rail connector, color: green, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2702636?
Proax is an authorized distributor of Phoenix Contact 2702636 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- PSI-TERMINATOR-PB, PROFIBUS or other RS-485 networks can be actively terminated at the end of the bus using the PSI-TERMINATOR-PB. This ensures safe communication even if the bus device is connected/disconnected during operation. In addition, the connectable termination enables the device to be operated as a service interface at any point in the bus system. For the operation of active programming and diagnostic devices, the required power supply is provided at the alternative D-SUB connection.