2708290
SKU
PHX2708290
MPN
PSI-MOS-PROFIB/FO 660 E
Weight
0.247 kg
Series PSI-MOS-PROFIB-FO
PSI-MOS-PROFIB/FO 660 E - FO converters
FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (FSMA), 660 nm, for polymer/PCF fiber cable
- Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
- Supply voltage and data signals routed through the DIN rail connectors
- Connections can be plugged in via a COMBICON screw terminal block
- Automatic data rate detection or fixed data rate setting via DIP switches
- Redundant power supply
- High-quality electrical isolation between all interfaces (PROFIBUS // fiber optic ports // power supply // DIN rail connector)
- Approved for use in zone 2
- Integrated optical diagnostics for continuous monitoring of FO paths
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Floating switch contact for advance warning of critical FO paths
- Suitable for all data rates up to 12 Mbps
- Bit retiming for any cascading depth
- Shipbuilding approval in accordance with DNV GL
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area | 
| CCCex note | Use in potentially explosive areas is not permitted in China. | 
Product properties
| MTTF | 243 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) | 
| MTTF | 178 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | 
| MTTF | 110 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | 
| MTBF | 324 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) | 
| MTBF | 70 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | 
Electrical properties
| Electrical isolation | VCC // RS-485 | 
| Maximum power dissipation for nominal condition | 2.4 W | 
| Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) | 
Supply
| Supply Voltage Range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) | 
| Nominal Supply Voltage | 24 V DC (in acc. with UL) | 
| Typical current consumption | 100 mA (24 V DC) | 
| Max. current consumption | 130 mA | 
| Max. current consumption | ≤ 2 A (For operation in a joining station, via the DIN rail connector) | 
Switching
| Output name | Relay output | 
| Output description | Alarm output | 
| Number of Outputs | 1 | 
| Maximum Switching Voltage | 60 V DC (Resistive Load, General Load) | 
| Maximum Switching Voltage | 30 V AC (Resistive load) | 
| Maximum Switching Voltage | 42 V AC (peak, resistive load) | 
| Limiting Continuous Current | 0.46 A | 
Supply
| Connection Method | COMBICON plug-in screw terminal block | 
| Stripping length | 7.00 mm | 
| Tightening torque | 0.56 Nm ... 0.79 Nm | 
Interfaces
| Bit distortion, input | ± 35 % (permitted) | 
| Bit distortion, output | < 6.25 % | 
| Bit delay | < 1 bit (DIP 7 = OFF, standard operation) | 
| Bit delay | 11 bit (DIP 7 = ON, redundancy operation) | 
| Signal | PROFIBUS | 
Data: optical FO
| No. of channels | 1 | 
| Transmit capacity, minimum | -3 dBm (980/1000 µm) | 
| Transmit capacity, minimum | -15.4 dBm (200/230 µm) | 
| Transmission length incl. 3 dB system reserve | 70 m (F-P 980/1000 230 dB/km with quick mounting connector) | 
| Transmission length incl. 3 dB system reserve | 400 m (F-K 200/230 10 dB/km with quick mounting connector) | 
| Transmission protocol | Protocol-transparent to the RS-485 interface | 
| Connection Method | F-SMA | 
| Wavelength | 660 nm | 
| Minimum receiver sensitivity | -30 dBm | 
| Maximum receiver sensitivity | -3 dBm (980/1000 µm) | 
| Transmission medium | Polymer fiber | 
| Transmission medium | PCF fiber | 
Data: PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control
| Serial transmission speed | ≤ 12 Mbps | 
| Connection Method | D-SUB-9 female connector | 
| Transmission length | ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable) | 
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² | 
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² | 
| Max. AWG conductor cross section, flexible | 14 | 
| Min. AWG conductor cross section, flexible | 24 | 
| Single-wire/terminal point, rigid AWG max. | 14 | 
| Single-wire/terminal point, rigid AWG min. | 24 | 
| Transmission medium | Copper | 
| File format/coding | UART (11 Bit, NRZ) | 
| Data direction switching | Automatic control | 
| Output nominal voltage | 5 V ±0.25 (50 mA) | 
Dimensions
| Width | 35 mm | 
| Height | 99 mm | 
| Depth | 106 mm | 
Material specifications
| Color (Housing) | green (RAL 6021) | 
| Material (Housing) | PA 6.6-FR | 
FO cable
| Fiber types | 980/1000 µm | 
| Fiber types | 200/230 µm | 
| Fiber types | Polymer fiber | 
| Fiber types | PCF fiber | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -20 °C ... 60 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) | 
| Altitude | ≤ 2000 m (Hazardous locations) | 
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) | 
CE
| Certificate | CE-compliant | 
ATEX
| Identification |  II 3 G Ex nA nC IIC T4 Gc X | 
| Note | Please follow the special installation instructions in the documentation! | 
ATEX, FO interface
| Identification |  II (2) G [Ex op is Gb] IIC | 
| Identification |  II (2) D [Ex op is Db] IIIC | 
| Certificate | PTB 06 ATEX 2042 U | 
| Note | Please follow the special installation instructions in the documentation! | 
UL, USA/Canada
| Identification | Class I, Zone 2, AEx nc IIC T5 | 
| Identification | Class I, Zone 2, Ex nC nL IIC T5 X | 
| Identification | Class I, Div. 2, Groups A, B, C, D | 
PROFIBUS interoperability
| Note | Tested by independent PNO test laboratory (PN059-485-01) | 
ABB certification
| Identification | IndustrialIT enabled | 
| Note | This certification is a trademark of ABB. | 
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A | 
Shipbuilding
| Identification | DNV GL | 
DNV GL data
| Temperature | B | 
| Humidity | A | 
| Vibration | A | 
| EMC | B | 
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | 
EMC data
| Noise immunity | EN 61000-6-2:2005 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Noise emission | EN 55011 | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Contact discharge | ± 6 kV | 
| Discharge in air | ± 8 kV | 
| Comments | Criterion B | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Field intensity | 10 V/m | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Input | ± 2 kV | 
| Signal | ± 2 kV | 
| Comments | Criterion B | 
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 | 
| Input | ± 0.5 kV | 
| Signal | ± 1 kV | 
| Comments | Criterion B | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Emitted interference
| Standards/regulations | EN 55011 | 
| Comments | Class A, industrial applications | 
Criteria
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
Standards and Regulations
| Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 | 
Air clearances and creepage distances
| Standards/regulations | DIN EN 60664-1 | 
| Standards/regulations | VDE 0110-1 | 
| Standards/regulations | DIN EN 50178 | 
| Standards/regulations | EN 60950 | 
Mounting
| Mounting Type | DIN rail mounting | 
Accessories
 ME 17,5 TBUS 1,5/ 5-ST-3,81 KMGY - DIN rail connector, color: light grey, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-17,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts ME 17,5 TBUS 1,5/ 5-ST-3,81 KMGY - DIN rail connector, color: light grey, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-17,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
 SUBCON-PLUS-PROFIB/PG/SC2 - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks SUBCON-PLUS-PROFIB/PG/SC2 - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
 SUBCON-PLUS-PROFIB/90/PG/SC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks SUBCON-PLUS-PROFIB/90/PG/SC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
 SUBCON-PLUS-PROFIB/90/PG/IDC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; IDC terminal block connection SUBCON-PLUS-PROFIB/90/PG/IDC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; IDC terminal block connection
Why Proax for Phoenix Contact 2708290?
Proax is an authorized distributor of Phoenix Contact 2708290 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 
Recommended