2708423
SKU
PHX2708423
MPN
PSI-MOS-RS232/FO 850 T
Weight
0.269 kg
This product is Not Cancellable/Not Returnable
Series PSI-MOS-RS
PSI-MOS-RS232/FO 850 T - FO converters
FO converter with integrated optical diagnostics, alarm contact, for RS-232 interfaces up to 115.2 kbps, T-coupler with two FO interfaces (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
- Supply voltage and data signals routed through the DIN rail connectors
- Connections can be plugged in via a COMBICON screw terminal block
- Redundant power supply possible by means of optional system power supply unit
- High-quality electrical isolation between all interfaces (RS-232 // fiber optic ports // power supply // DIN rail connector)
- Approved for use in zone 2
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Integrated optical diagnostics for continuous monitoring of FO paths
- Floating switch contact for advance warning of critical FO paths
- Automatic data rate detection for all data rates up to 115.2 kbps
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area | 
| CCCex note | Use in potentially explosive areas is not permitted in China. | 
Product properties
| MTTF | 789 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) | 
| MTTF | 324 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | 
| MTTF | 134 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | 
| MTBF | 177 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) | 
| MTBF | 26 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | 
Electrical properties
| Electrical isolation | VCC // V.24 (RS-232) | 
| Maximum power dissipation for nominal condition | 2.88 W | 
| Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) | 
Supply
| Supply Voltage Range | 18 V DC ... 30 V DC | 
| Nominal Supply Voltage | 24 V DC (in acc. with UL) | 
| Typical current consumption | 120 mA (24 V DC) | 
| Max. current consumption | 120 mA | 
Switching
| Output name | Relay output | 
| Output description | Alarm output | 
| Number of Outputs | 1 | 
| Maximum Switching Voltage | 60 V DC | 
| Maximum Switching Voltage | 42 V AC | 
| Limiting Continuous Current | 0.46 A | 
Supply
| Connection Method | COMBICON plug-in screw terminal block | 
| Tightening torque | 0.56 Nm ... 0.79 Nm | 
Interfaces
| Bit distortion, input | ± 35 % (permitted) | 
| Bit distortion, output | < 6.25 % | 
| Signal | Modbus | 
| Transmission channels | 2 (1/1), RxD, TxD, full duplex | 
Data: optical FO
| No. of channels | 2 | 
| Transmit capacity, minimum | -4.6 dBm (200/230 µm) | 
| Transmit capacity, minimum | -17.6 dBm (50/125 µm) | 
| Transmit capacity, minimum | -13.6 dBm (62,5/125 µm) | 
| Transmission length incl. 3 dB system reserve | 2800 m (F-K 200/230 8 dB/km with quick mounting connector) | 
| Transmission length incl. 3 dB system reserve | 4200 m (with F-G 50/125 2.5 dB/km) | 
| Transmission length incl. 3 dB system reserve | 4800 m (with F-G 62,5/125 3.0 dB/km) | 
| Transmission protocol | Transparent to protocol for RS-232 interface | 
| Connection Method | B-FOC (ST®) | 
| Wavelength | 850 nm | 
| Minimum receiver sensitivity | -33.2 dBm | 
| Transmission medium | PCF fiber | 
| Transmission medium | Multi-mode fiberglass | 
Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
| Serial transmission speed | 4.8 Kbps ... 115.2 Kbps | 
| Connection Method | D-SUB 9 plug | 
| Transmission length | ≤ 15 m | 
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² | 
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² | 
| Max. AWG conductor cross section, flexible | 14 | 
| Min. AWG conductor cross section, flexible | 24 | 
| Single-wire/terminal point, rigid AWG max. | 14 | 
| Single-wire/terminal point, rigid AWG min. | 24 | 
| Transmission medium | Copper | 
| File format/coding | UART (11 Bit, NRZ) | 
| Data direction switching | Automatic control | 
Dimensions
| Width | 35 mm | 
| Height | 99 mm | 
| Depth | 105 mm | 
Material specifications
| Color (Housing) | green (RAL 6021) | 
| Material (Housing) | PA 6.6-FR | 
FO cable
| Fiber types | 200/230 µm | 
| Fiber types | 50/125 µm | 
| Fiber types | 62.5/125 µm | 
| Fiber types | PCF fiber | 
| Fiber types | Fiberglass | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -20 °C ... 60 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) | 
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) | 
CE
| Certificate | CE-compliant | 
ATEX
| Identification |  II 3 G Ex nA nC IIC T4 Gc X | 
| Note | Please follow the special installation instructions in the documentation! | 
ATEX, FO interface
| Identification |  II (2) G [Ex op is Gb] IIC | 
| Identification |  II (2) D [Ex op is Db] IIIC | 
| Certificate | PTB 06 ATEX 2042 U | 
| Note | Please follow the special installation instructions in the documentation! | 
UL, USA/Canada
| Identification | Class I, Zone 2, AEx nc IIC T5 | 
| Identification | Class I, Zone 2, Ex nC nL IIC T5 X | 
| Identification | Class I, Div. 2, Groups A, B, C, D | 
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A | 
EMC data
| Noise immunity | EN 61000-6-2:2005 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Noise emission | EN 55011 | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Contact discharge | ± 6 kV | 
| Discharge in air | ± 8 kV | 
| Comments | Criterion B | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Comments | Criterion B | 
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 | 
| Comments | Criterion B | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Emitted interference
| Standards/regulations | EN 55011 | 
| Comments | Class A, industrial applications | 
Criteria
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
Standards and Regulations
| Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 | 
Mounting
| Mounting Type | DIN rail mounting | 
Accessories
 PSM-HCS-KONFTOOL/B-FOC - HCS assembly kit for B-FOC(ST) quick mounting connectors, including stripping blade, stripping pliers, aramide yarn scissors, fiber stripper, microscope, fiber cleaving tool for standard HCS and HCS GI fibers, four B-FOC(ST) connectors for standard HCS fiber, and documentation PSM-HCS-KONFTOOL/B-FOC - HCS assembly kit for B-FOC(ST) quick mounting connectors, including stripping blade, stripping pliers, aramide yarn scissors, fiber stripper, microscope, fiber cleaving tool for standard HCS and HCS GI fibers, four B-FOC(ST) connectors for standard HCS fiber, and documentation
Why Proax for Phoenix Contact 2708423?
Proax is an authorized distributor of Phoenix Contact 2708423 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 