PLC-RSC- 24DC/ 1ICT/ACT - Relay Module
PLC-INTERFACE for high inrush currents, consisting of PLC-BSC.../1 IC/ACT basic terminal block with screw connection and pluggable miniature relay, for mounting on DIN rail NS 35/7.5, max. inrush current up to 800 A, 1 N/O contact, 24 V DC input voltage
- Direct connection of load return line thanks to actuator version
- Efficient connection to system cabling using V8 adapter
- Safe isolation between coil and contact side
- Max. inrush current of 800 A
- Functional plug-in bridges
PLC-RSC
The Phoenix Contact PLC-RSC Series is part of the PLC-INTERFACE family, offering compact relay modules designed for efficient signal isolation and amplification in industrial automation systems. These modules are engineered for DIN rail mounting and feature plug-in miniature relays with power contacts, ensuring reliable performance in various control applications.
Key Features:
- ✅ Compact Design: With a slim 6.2 mm width, the PLC-RSC modules save space in control cabinets, allowing for high-density installations.
- ✅ Versatile Contact Configurations: Available with different contact types, including single changeover (SPDT) and double changeover (DPDT) contacts, to suit diverse application needs.
- ✅ Wide Input Voltage Range: Models support various input voltages, such as 24 V DC, 230 V AC, and 220 V DC, providing flexibility for integration into different control systems.
- ✅ High Switching Capacity: Designed to handle currents up to 6 A, these modules are suitable for switching both resistive and inductive loads.
- ✅ Integrated Protective Features: Equipped with reverse polarity protection and freewheeling diodes, the PLC-RSC modules ensure safe and reliable operation.
- ✅ Manual Operation Option: Certain models include a manual operation lever, facilitating easy testing and maintenance without the need for external actuation.
Notes
Notes on operation | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
Notes on operation | The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
Assembly instruction: | The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
Notes on operation | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Product properties
Product family | PLC-INTERFACE |
Application | high inrush currents |
Operating mode | 100% operating factor |
Mechanical service life | 3x 107 cycles |
Insulation characteristics
Insulation | Safe isolation, reinforced insulation |
Insulation characteristics: Standards/regulations
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 3 |
Electrical properties
Maximum power dissipation for nominal condition | 0.43 W |
Test voltage (Winding/contact) | 4 kV AC (50 Hz, 1 min., winding/contact) |
Standards/regulations
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 24 V DC |
Input voltage range | 20.2 V DC ... 33.6 V DC (20 °C) |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 18 mA |
Typical response time | 8 ms |
Typical release time | 10 ms |
Coil Voltage | 24 V DC |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Freewheeling diode; Freewheeling diode |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 1 N/O contact |
Type of switch contact | Single contact |
Note regarding the switch contact | With tungsten leading contact |
Contact Material | AgSnO |
Note | Main contact silver tin oxide (AgSnO2): lead contact tungsten |
Maximum Switching Voltage | 250 V AC/DC |
Minimum Switching Voltage | 12 V (100 mA) |
Limiting Continuous Current | 6 A |
Limiting Continuous Current | 10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged) |
Maximum Inrush Current | 165 A (20 ms) |
Maximum Inrush Current | 800 A (200 µs) |
Min. switching current | 100 mA (12 V) |
Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
Interrupting rating (ohmic load) max. | 58 W (at 48 V DC) |
Interrupting rating (ohmic load) max. | 48 W (at 60 V DC) |
Interrupting rating (ohmic load) max. | 50 W (at 110 V DC) |
Interrupting rating (ohmic load) max. | 80 W (at 220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (for 250 V AC) |
Interrupting rating (ohmic load) max. bridged | 240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
Interrupting rating (ohmic load) max. bridged | 2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
Switching capacity min. | 1200 mW |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 0.2 A (at 110 V, DC13) |
Switching capacity | 0.2 A (at 250 V, DC13) |
Switching capacity | 6 A (at 24 V, AC15) |
Switching capacity | 6 A (at 120 V, AC15) |
Switching capacity | 6 A (at 250 V, AC15) |
Connection data
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.6 Nm ... 0.8 Nm |
Dimensions
Width | 14 mm |
Height | 80 mm |
Depth | 94 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of protection (Relay) | RT II (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Standards/regulations
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
- PLC-V8L/FLK14/OUT - V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
- V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: minusschaltend
Why Proax for Phoenix Contact 1078680?
Proax is an authorized distributor of Phoenix Contact 1078680 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Pack Size | 10 |