Weight
0.194 kg
Series PSR-SCP
PSR-SCP- 24UC/ESL4/3X1/1X2/B - Safety relays
Safety relay for emergency stop, safety doors, and light grids up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
- Manually monitored and automatic activation
- Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- Three enabling and one signaling current path
- 1- and 2-channel control
Technical Specifications
Product properties
Product family | PSRclassic |
Application | Emergency stop |
Application | Safety door |
Application | Light grid |
Mechanical service life | approx. 107 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | 125 ms (automatic start) |
Typical response time | 110 ms (manual, monitored start) |
Typ. starting time with Us | 125 ms (when controlled via A1) |
Typical release time | 10 ms (on demand via the sensor circuit) |
Typical release time | 45 ms (on demand via A1) |
Restart time | < 1 s (Boot time) |
Recovery time | 1 s (following demand of the safety function) |
Electrical properties
Maximum power dissipation for nominal condition | 16.44 W (at US = 26.4 V, IL² = 72 A²;PTotal max=2.04 W+14.4 W) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V |
Rated Insulation Voltage | 250 V |
Rated surge voltage/insulation | See section “Insulation coordination” |
Supply
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Rated control supply current IS | typ. 70 mA (at US) |
Power consumption at US | typ. 1.68 W |
Inrush Current | < 3.5 A (typically with US, Δt = 3 ms) |
Filter time | 5 ms (in the event of voltage dips at Us, no test pulses allowed) |
Protective circuit | Serial protection against polarity reversal; Suppressor diode |
Digital: Logic (S12, S22)
Description of the input | safety-related |
Number of Inputs | 2 |
Input voltage range "0" signal | 0 V DC ... 5 V DC |
Input voltage range "1" signal | 20.4 V ... 26.4 V |
Input current range "0" signal | 0 mA ... 2 mA |
Inrush Current | max. 110 mA (typically with US, Δt = 3 ms) |
Filter time | max. 2 ms (Test pulse width low test pulses, at 100 ms test pulse rate) |
Filter time | No brightness test pulses / high test pulses permitted. |
Concurrence | ∞ |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 38 mA (typically with US) |
Digital: Start circuit (S34, S35)
Description of the input | non-safety-related |
Number of Inputs | 2 |
Input voltage range "1" signal | 20.4 V ... 26.4 V |
Inrush Current | < 6 mA (typically with US at S34/35, Δt = 70 ms) |
Filter time | No test pulses permitted |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 0 mA (Typically with US at S34) |
Current consumption | 1 mA (Typically with US at S35) |
Relay: Enabling current paths (13/14, 23/24, 33/34)
Output description | 2 N/O contacts each in series, safety-related, floating |
Number of Outputs | 3 |
Contact switching type | 3 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 10 V |
Switching voltage | max. 250 V AC |
Switching capacity | min. 100 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 6 A (DC13) |
Limiting Continuous Current | 6 A (Observe derating and load limit curve) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 10 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Relay: Signaling current path (41/42)
Output description | 2 N/C contacts parallel, non-safety-related, floating |
Number of Outputs | 1 |
Contact switching type | 1 signaling current path |
Contact Material | AgSnO2 |
Switching voltage | min. 10 V AC/DC |
Switching voltage | max. 250 V AC |
Switching capacity | min. 100 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 1.5 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 2 A (DC13) |
Limiting Continuous Current | 6 A |
Sq. Total current | 36 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 6 A gL/gG |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
Status display | 2 x green LEDs |
Operating voltage display | 1 x green LED |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 |
Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, amplitude 0.15 mm, 2g |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 60947-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Why Proax for Phoenix Contact 2981059?
Proax is an authorized distributor of Phoenix Contact 2981059 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended