PSR-SCP- 24DC/ESP4/2X1/1X2 - Safety relays
Safety relay for SIL 3 high-demand and low-demand applications, also approved in accordance with EN 50156, DNV, and EN ISO 13849, emergency stop and safety door monitoring, 1-channel, 2 enabling current paths, 1 signal contact, plug-in screw terminal blocks, width: 22.5 mm
- Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- 1-channel control
- Safe isolation
- With inrush current reduction, therefore suitable for coupling to failsafe controllers (PSR-ESP4)
Technical Specifications
Product properties
Product family | PSRclassic |
Application | Emergency stop |
Application | Process technology |
Application | Safety door |
Mechanical service life | approx. 107 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | typ. 60 ms (For Us manual, monitored start) |
Typical response time | 60 ms (For Us autostart) |
Typ. starting time with Us | 60 ms (At Us/on demand via A1) |
Typical release time | typ. 20 ms (At Us/on demand via A1) |
Restart time | < 1 s (Boot time) |
Recovery time | ≥ 1 s (following demand of the safety function) |
Electrical properties
Maximum power dissipation for nominal condition | 16.12 W (At US = 26.4 V, IL² = 72 A², PTotal max= 1.72 W + 14.4 W) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V |
Rated Insulation Voltage | 250 V |
Rated surge voltage/insulation | See section “Insulation coordination” |
Digital: Logic (A1)
Description of the input | safety-related |
Number of Inputs | 1 |
Input voltage range "1" signal | 20.4 V ... 26.4 V |
Inrush Current | max. 1 A (typically with US, Δt = < 10 ms) |
Filter time | max. 3 ms (Test pulse width of low test pulses) |
Filter time | min. 200 ms (Test pulse rate for low test pulse) |
Filter time | No brightness test pulses / high test pulses permitted. |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 65 mA (typically with US) |
Digital: Start circuit (Y2)
Description of the input | non-safety-related |
Number of Inputs | 1 |
Input voltage range "1" signal | 20.4 V ... 26.4 V |
Inrush Current | < 14 mA (typically with US at Y2, Δt - 10 ms) |
Filter time | No test pulses permitted |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 0 mA (typically with US at Y2) |
Relay: Enabling current paths (13/14, 23/24)
Output description | 2 N/O contacts each in series, safety-related, floating |
Number of Outputs | 2 |
Contact switching type | 2 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 10 V |
Switching voltage | max. 250 V AC |
Switching capacity | min. 100 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (DC13) |
Limiting Continuous Current | 6 A (Observe derating and load limit curve) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 107 cycles |
Interrupting rating (ohmic load) max. | Observe derating and load limit curve |
Maximum interrupting rating (inductive load) | Observe derating and load limit curve |
Output fuse | 10 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Relay: Signaling current path (31/32)
Output description | 2 N/C contacts parallel, non-safety-related, floating |
Number of Outputs | 1 |
Contact switching type | 1 signaling current path |
Contact Material | AgSnO2 |
Switching voltage | min. 10 V AC/DC |
Switching voltage | max. 250 V AC |
Switching capacity | min. 100 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 1.5 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 2 A (DC13) |
Limiting Continuous Current | 6 A |
Sq. Total current | 36 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 107 cycles |
Interrupting rating (ohmic load) max. | Observe derating and load limit curve |
Maximum interrupting rating (inductive load) | Observe derating and load limit curve |
Output fuse | 6 A gL/gG |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Signaling
Status display | Green LED |
Operating voltage display | Green LED |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 |
Performance level (PL) | e |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 60947-1 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | On horizontal and vertical DIN rail |
Why Proax for Phoenix Contact 2981020?
Proax is an authorized distributor of Phoenix Contact 2981020 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended