PSR-SCP- 24DC/ESD/5X1/1X2/1T 5 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with a fixed dropout delay of 1.5 s, plug-in screw connection terminal blocks

  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Fixed delay times of 1.5 s
  • 1- and 2-channel control
  • 3 undelayed and 2 dropout delay contacts
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

ApplicationEmergency stop
ApplicationSafety door
ApplicationLight grid
Mechanical service life10x 106 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Electrical properties

Maximum power dissipation for nominal condition3.6 W
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV:between all current paths and housingSafe isolation, reinforced insulation 6 kV:between 13/14, 23/24, 33/34, and the remaining current pathsbetween 13/14, 23/24, 33/34 among one another

General

Rated control circuit supply voltage US24 V DC -15 % / +10 %
Power consumption at UStyp. 3.6 W
Rated control supply current IStyp. 150 mA
Inrush Current200 mA (at US)
Inrush Current< 40 mA (with Us/Ix to S10)
Inrush Current< 150 mA (with Us/Ix to S12)
Inrush Current> -60 mA (with Us/Ix to S22)
Inrush Current< 40 mA (with Us/Ix to S34)
Inrush Current< 40 mA (with Us/Ix to S35)
Current consumption< 40 mA (with Us/Ix to S10)
Current consumption< 40 mA (with Us/Ix to S12)
Current consumption> -40 mA (with Us/Ix to S22)
Current consumption0 mA (with Us/Ix to S34)
Current consumption< 5 mA (with Us/Ix to S35)
Voltage at input/start and feedback circuit24 V DC -15 % / +10 %
Filter time1 ms (at A1 in the event of voltage dips at Us)
Filter timemax. 1.5 ms (at S10, S12; test pulse width)
Filter time7.5 ms (at S10, S12; test pulse rate)
Filter timeTest pulse rate = 5 x Test pulse width
Typical response time< 600 ms (automatic start)
Typical response time< 70 ms (manual start)
Typ. starting time with Us< 600 ms (when controlled via A1)
Typical release time< 20 ms (when controlled via S11/S12 and S21/S22)
Typical release time< 20 ms (when controlled via A1)
Concurrence
Recovery time< 1 s
Delay timeK3(t), K4(t) fixed depending on model
Maximum switching frequency0.5 Hz
Protective circuitSurge protection; Suppressor diode
Max. permissible overall conductor resistanceapprox. 11 Ω (Input and start circuits at US)
Operating voltage display1 x green LED
Status display4 x green LEDs

Output data

Contact switching type5 enabling current paths
Contact switching type1 signaling current path
Contact MaterialAgSnO2
Maximum Switching Voltage250 V AC/DC (Observe the load curve)
Minimum Switching Voltage5 V AC/DC
Limiting Continuous Current6 A (N/O contact, pay attention to the derating)
Limiting Continuous Current6 A (N/C contact)
Maximum Inrush Current20 A (Δt  100 ms, undelayed contacts)
Maximum Inrush Current8 A (delayed contacts)
Inrush current, minimum10 mA
Sq. Total current55 A2 (observe derating)
Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.288 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.110 W (110 V DC, τ = 0 ms, delayed contacts: 77 W)
Interrupting rating (ohmic load) max.88 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000 VA)
Maximum interrupting rating (inductive load)42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W)
Maximum interrupting rating (inductive load)42 W (48 V DC, τ = 40 ms, delayed contacts: 40 W)
Maximum interrupting rating (inductive load)42 W (110 V DC, τ = 40 ms, delayed contacts: 35 W)
Maximum interrupting rating (inductive load)42 W (220 V DC, τ = 40 ms, delayed contacts: 33 W)
Switching capacity min.50 mW
Switching capacity (360/h cycles)4 A (24 V DC)
Switching capacity (360/h cycles)4 A (230 V AC)
Switching capacity (3600/h cycles)2.5 A (24 V (DC13))
Switching capacity (3600/h cycles)3 A (230 V (AC15))
Output fuse10 A gL/gG (N/O contact)
Output fuse6 A gL/gG (N/C contact)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section, rigid0.2 mm² ... 2.5 mm²
Conductor cross section, flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Stripping length7 mm
Screw threadM3

Dimensions

Width45 mm
Height99 mm
Depth114.5 mm

Material specifications

Coloryellow
Housing MaterialPBT

Safety data

Stop category0
Stop category1

Safety data: EN ISO 13849

Category4 (Undelayed contacts)
Category3 (delayed contacts)
Performance level (PL)e (for delayed contacts PL d)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3 (for delayed contacts SIL 2)

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)3 (for delayed contacts SIL 2)

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (for delayed contacts SIL 2)

Ambient conditions

Degree of ProtectionIP54
Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

CertificateCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178/VDE 0160

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany

Why Proax for Phoenix Contact 2981169?

Proax is an authorized distributor of Phoenix Contact 2981169 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability