Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2981800
Weight
0.229 kg
Series PSR-SCP

PSR-SCP- 24DC/ESD/4X1/30 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, automatic or manual activation, 2 N/O contacts with a dropout delay of 0.1 s ... 30 s, plug-in screw connection terminal block

  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat. 3/4 and PL d/e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • 1- and 2-channel control
  • Protective labels to prevent manipulation of the set time (PSR-ESD-300) or electronic protection against manipulation (PSR-ESD-30)
  • Fixed delay times of 0.1 s ... 300 s
Technical Specifications

Product properties

Product familyPSRclassic
ApplicationEmergency stop
ApplicationSafety door
ApplicationLight grid
Set comprises1217839 PSR-SCP-24DC/ESD/4X1/30-SET35
Mechanical service lifeapprox. 107 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Typical response time150 ms (Monitored/manual and auto-start)
Typical release time20 ms (Undelayed contacts)
Typical release time100 ms (delayed contacts)
Delay time range0.1 s ... 30 s ±30 % (adjustable)
Recovery time330 ms (Restart)
Recovery time1 s (Electric torque)

Electrical properties

Maximum power dissipation for nominal condition1.8 W
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V
Rated surge voltage/insulation4 kV / basic insulation

Supply

Rated control circuit supply voltage US24 V DC
Inrush Currenttyp. 250 mA

General

Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN75 mA DC
Voltage at input/start and feedback circuitapprox. 24 V DC
Typical response time150 ms (Monitored/manual and auto-start)
Typical release time20 ms (Undelayed contacts)
Typical release time100 ms (delayed contacts)
Typical release time range0.1 s ... 30 s
Recovery time330 ms (Restart)
Recovery time1 s (Electric torque)
Protective circuitSuppressor diode, 33 V DC
Max. permissible overall conductor resistance500 Ω (Input and reset circuit at UN)
Operating voltage displayGreen LED
Status displayLED K1/K2 and K3(t)/K4(t), green

Output data

Contact switching type4 enabling current paths
Contact MaterialAgSnO2
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage15 V AC/DC
Limiting Continuous Current6 A (N/O contact)
Maximum Inrush Current6 A
Inrush current, minimum25 mA
Sq. Total current120 A2 (see to derating)
Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.288 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.90 W (110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.88 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)33 W (48 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)25 W (110 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)23 W (220 V DC, τ = 40 ms)
Switching capacity min.0.4 W
Switching capacity (360/h cycles)on request
Switching capacity (3600/h cycles)3 A (24 V (DC13))
Switching capacity (3600/h cycles)3 A (230 V (AC15))
Output fuse10 A gL/gG NEOZED (N/O contact)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Housing MaterialPolyamide

Safety data

Stop category0
Stop category1

Safety data: EN ISO 13849

Category4
Performance level (PL)e

Safety data

Safety Integrity Level (SIL)3

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 45 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 60947-1

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany

Why Proax for Phoenix Contact PSR-SCP- 24DC/ESD/4X1/30?

Proax is an authorized distributor of Phoenix Contact PSR-SCP- 24DC/ESD/4X1/30 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPSRSCP24DCESD4X130
Pack Size1
Recommended

Available for order