PSR-SCP- 24DC/ESD/5X1/1X2/ T 4 - Safety relays
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with a fixed dropout delay of 4 s, plug-in screw connection terminal blocks
- For emergency stop and safety door monitoring, plus evaluation of light grids
- Fixed delay times of 4 s
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Application | Emergency stop |
Application | Safety door |
Application | Light grid |
Mechanical service life | 10x 106 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Electrical properties
Maximum power dissipation for nominal condition | 3.6 W |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV:between all current paths and housingSafe isolation, reinforced insulation 6 kV:between 13/14, 23/24, 33/34, and the remaining current pathsbetween 13/14, 23/24, 33/34 among one another |
General
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Power consumption at US | typ. 3.6 W |
Rated control supply current IS | typ. 150 mA |
Inrush Current | 200 mA (at US) |
Inrush Current | < 40 mA (with Us/Ix to S10) |
Inrush Current | < 150 mA (with Us/Ix to S12) |
Inrush Current | > -60 mA (with Us/Ix to S22) |
Inrush Current | < 40 mA (with Us/Ix to S34) |
Inrush Current | < 40 mA (with Us/Ix to S35) |
Current consumption | < 40 mA (with Us/Ix to S10) |
Current consumption | < 40 mA (with Us/Ix to S12) |
Current consumption | > -40 mA (with Us/Ix to S22) |
Current consumption | 0 mA (with Us/Ix to S34) |
Current consumption | < 5 mA (with Us/Ix to S35) |
Voltage at input/start and feedback circuit | 24 V DC -15 % / +10 % |
Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
Filter time | max. 1.5 ms (at S10, S12; test pulse width) |
Filter time | 7.5 ms (at S10, S12; test pulse rate) |
Filter time | Test pulse rate = 5 x Test pulse width |
Typical response time | < 600 ms (automatic start) |
Typical response time | < 70 ms (manual start) |
Typ. starting time with Us | < 600 ms (when controlled via A1) |
Typical release time | < 20 ms (when controlled via S11/S12 and S21/S22) |
Typical release time | < 20 ms (when controlled via A1) |
Concurrence | ∞ |
Recovery time | < 1 s |
Delay time | K3(t), K4(t) fixed depending on model |
Maximum switching frequency | 0.5 Hz |
Protective circuit | Surge protection; Suppressor diode |
Max. permissible overall conductor resistance | approx. 11 Ω (Input and start circuits at US) |
Operating voltage display | 1 x green LED |
Status display | 4 x green LEDs |
Output data
Contact switching type | 5 enabling current paths |
Contact switching type | 1 signaling current path |
Contact Material | AgSnO2 |
Maximum Switching Voltage | 250 V AC/DC (Observe the load curve) |
Minimum Switching Voltage | 5 V AC/DC |
Limiting Continuous Current | 6 A (N/O contact, pay attention to the derating) |
Limiting Continuous Current | 6 A (N/C contact) |
Maximum Inrush Current | 20 A (Δt 100 ms, undelayed contacts) |
Maximum Inrush Current | 8 A (delayed contacts) |
Inrush current, minimum | 10 mA |
Sq. Total current | 55 A2 (observe derating) |
Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 288 W (48 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 110 W (110 V DC, τ = 0 ms, delayed contacts: 77 W) |
Interrupting rating (ohmic load) max. | 88 W (220 V DC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | 1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000 VA) |
Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W) |
Maximum interrupting rating (inductive load) | 42 W (48 V DC, τ = 40 ms, delayed contacts: 40 W) |
Maximum interrupting rating (inductive load) | 42 W (110 V DC, τ = 40 ms, delayed contacts: 35 W) |
Maximum interrupting rating (inductive load) | 42 W (220 V DC, τ = 40 ms, delayed contacts: 33 W) |
Switching capacity min. | 50 mW |
Switching capacity (360/h cycles) | 4 A (24 V DC) |
Switching capacity (360/h cycles) | 4 A (230 V AC) |
Switching capacity (3600/h cycles) | 2.5 A (24 V (DC13)) |
Switching capacity (3600/h cycles) | 3 A (230 V (AC15)) |
Output fuse | 10 A gL/gG (N/O contact) |
Output fuse | 6 A gL/gG (N/C contact) |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section, rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Dimensions
Width | 45 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color | yellow |
Housing Material | PBT |
Safety data
Stop category | 0 |
Stop category | 1 |
Safety data: EN ISO 13849
Category | 4 (Undelayed contacts) |
Category | 3 (delayed contacts) |
Performance level (PL) | e (for delayed contacts PL d) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 (for delayed contacts SIL 2) |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 (for delayed contacts SIL 2) |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 (for delayed contacts SIL 2) |
Ambient conditions
Degree of Protection | IP54 |
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Certificate | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 50178/VDE 0160 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Why Proax for Phoenix Contact 2981240?
Proax is an authorized distributor of Phoenix Contact 2981240 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended