By Phoenix Contact

SKU
MPN
2981952
Weight
0.172 kg
Series PSR-SCP

PSR-SCP- 24UC/URM/5X1/1X2 - Coupling relay

Safe coupling relay with force-guided contacts, 5 N/O contacts, 1 N/C contact, plug-in screw terminal block, width: 22.5 mm

  • Up to Cat. 1/PL c in accordance with EN ISO 13849-1, SIL 1 in accordance with IEC 61508
  • Safe readback due to force-guided signal contact in accordance with EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • 1 or 2-channel control
  • 5 enabling current paths, 1 confirmation current path
Technical Specifications

Product properties

Product familyPSRclassic
ApplicationSafe switch off
ApplicationHigh demand
ApplicationLow demand
Mechanical service life10x 106 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Restart time< 1 s (Boot time)

Electrical properties

Maximum power dissipation for nominal condition8.56 W (at UB = 26.4 V DC, US = 24 V, IS = 47 mA, n = 1, IL² = 72 A², Rcontact = 0.1 )
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V
Rated Insulation Voltage250 V
Rated surge voltage/insulation4 kV / basic isolation (safe isolation, reinforced isolation and 6 kV between A1/A2, 53/54, 71/72 and 13/14, 23/24, 33/34, 43/44.)

General

Rated control circuit supply voltage US24 V AC/DC -15 % / +10 %
Power consumption at UStyp. 1.2 W
Rated control supply current IStyp. 47 mA
Input voltage range20.4 V AC/DC ... 26.4 V AC/DC
Inrush Currenttyp. 350 mA DC (Δt < 1 µs at Us)
Inrush Currenttyp. 350 mA AC (Δt = 2 ms at Us)
Typ. starting time with Ustyp. 20 ms (when controlled via A1)
Typical release timetyp. 20 ms (when controlled via A1)
Recovery time< 500 ms
Maximum switching frequency0.5 Hz
Protective circuitSurge protection; Varistor
Operating voltage display1 x green LED

Output data

Contact switching type5 enabling current paths
Contact switching type1 confirmation current path
Contact MaterialAgSnO2
Maximum Switching Voltage230 V AC/DC (Observe the load curve)
Minimum Switching Voltage5 V AC/DC
Limiting Continuous Current6 A (N/O contact)
Limiting Continuous Current6 A (N/C contact)
Maximum Inrush Current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2
Interrupting rating (ohmic load) max.144 W (N/O contact, 24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.288 W (N/O contact, 48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.240 W (N/O contact, 60 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.110 W (N/O contact, 110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.88 W (N/O contact, 220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.1380 VA (N/O contact, 230 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 48 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 60 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 110 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 220 V DC, τ = 40 ms)
Switching capacitymin. 50 mW
Switching capacity in accordance with IEC 60947-5-13 A (24 V (DC13))
Switching capacity in accordance with IEC 60947-5-13 A (230 V (AC 15))
Switching capacity (360/h cycles)4 A (24 V (DC13))
Switching capacity (360/h cycles)4 A (230 V (AC15))
Output fuse10 A gL/gG (N/O contact)
Output fuse4 A gL/gG (N/O contact, for low-demand applications)
Output fuse6 A gL/gG (N/C contact)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3
Tightening torque0.6 Nm

Dimensions

Width22.5 mm
Height114.5 mm
Depth99 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category1
Performance level (PL)c

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)1

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)1

Safety data

Safety Integrity Level (SIL)1

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitudemax. 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Vibration (Operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)

CE

CertificateCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178

Mounting

Mounting TypeDIN rail mounting
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact PSR-SCP- 24UC/URM/5X1/1X2?

Proax is an authorized distributor of Phoenix Contact PSR-SCP- 24UC/URM/5X1/1X2 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPSRSCP24UCURM5X11X2
Pack Size1
Recommended

Available for order