Official Distributor
SKU
MPN
PSR-SCP- 24DC/URM4/4X1/2X2/B
Weight
0.186 kg
This product is Not Cancellable/Not Returnable
Series PSR-SCP
PSR-SCP- 24DC/URM4/4X1/2X2/B - Extension module
1-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, undelayed, Cat. 4, PL e in accordance with EN ISO 13849, plug-in screw terminal blocks, width: 22.5 mm
- 4 enabling current paths, 1 signaling current path, and 1 confirmation current path
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
Technical Specifications
Product properties
Product family | PSRclassic |
Application | Extension module |
Mechanical service life | approx. 107 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typ. starting time with Us | 10 ms (when controlled via K1/K2) |
Typical release time | 10 ms (when requested via K1/K2) |
Electrical properties
Maximum power dissipation for nominal condition | 16.14 W (UN = 26.4 V, IL² = 72 A², PTotal max = 1.74 W + 14.4 W) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V |
Rated surge voltage/insulation | 4 kV / basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit/N/C contacts and enabling current paths). |
Digital: K1/K2
Description of the input | safety-related |
Number of Inputs | 1 |
Input voltage range "1" signal | 21.6 V DC ... 26.4 V DC |
Inrush Current | < 130 mA (Δt = 800 ms) |
Protective circuit | Suppressor diode |
Current consumption | typ. 60 mA |
Relay: Enabling current paths (23/24, 33/34, 43/44, 53/54)
Output description | 2 N/O contacts each in series, safety-related, floating |
Number of Outputs | 4 |
Contact switching type | 4 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 5 V AC/DC |
Switching voltage | max. 250 V AC |
Switching capacity | min. 50 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 6 A (DC13) |
Limiting Continuous Current | 6 A (Observe derating and load limit curve) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 10 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Relay: Confirmation current path (11/12)
Output description | Diagnostic contact, 2 NC in series, floating |
Number of Outputs | 1 |
Contact switching type | 2 N/C contacts in series, floating |
Contact Material | AgSnO2 |
Switching voltage | min. 5 V AC/DC |
Switching voltage | max. 26.4 V AC/DC |
Switching capacity | min. 50 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 1 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 1 A (DC13) |
Limiting Continuous Current | 1 A |
Sq. Total current | 1 A2 |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 1 A gL/gG |
Relay: Signaling current path (61/62)
Output description | 2 N/C contacts in parallel, floating |
Number of Outputs | 1 |
Switching voltage | min. 5 V AC/DC |
Switching voltage | 250 V AC |
Switching capacity | min. 50 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 1 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 1 A (DC13) |
Limiting Continuous Current | 1 A |
Sq. Total current | 1 A2 |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 1 A (gL/gG) |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
Operating voltage display | 1 x green LED |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 (In conjunction with suitable evaluating device) |
Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 60664-1 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2981677?
Proax is an authorized distributor of Phoenix Contact 2981677 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |