Series PSR-SCP
PSR-SCP- 24UC/URM4/5X1/2X2 - Extension module
1-channel or 2-channel contact extension, 5 N/O contacts, 1 N/C contact, 1 confirmation current path, together with basic device up to Cat. 4 PL e in accordance with EN ISO 13849 safe isolation, width: 35 mm, pluggable screw terminal block
- Five enabling, one signaling, and one confirmation current path
- 1- and 2-channel control
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
Technical Specifications
Product properties
Product family | PSRclassic |
Application | Extension module |
Mechanical service life | approx. 107 cycles |
Relay type | Safety relay for contact extension |
Times
Typ. starting time with Us | < 20 ms (at Us / when controlled via A11/A12) |
Typical release time | < 20 ms (at Us / when controlled via A11/A12) |
Recovery time | < 1 s |
Electrical properties
Maximum power dissipation for nominal condition | 15.8 W (US = 26.4 V, IL² = 72 A², PTotal max = 1.4 W + 14.4 W) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V |
Rated surge voltage/insulation | See section “Insulation coordination” |
General
Rated control circuit supply voltage US | 24 V -20 % ... +10 % |
Power consumption at US | 1 W (with DC) |
Power consumption at US | 1.2 W (with AC) |
Rated control supply current IS | typ. 39 mA (per channel, DC) |
Rated control supply current IS | typ. 50 mA (per channel, AC) |
Inrush Current | typ. 200 mA (Δt = 2 ms at Us, per channel) |
Protective circuit | Surge protection; Varistor (40 V breakdown voltage) |
Output data
Contact switching type | 5 enabling current paths |
Contact switching type | 1 confirmation current path |
Contact switching type | 1 signaling current path |
Contact Material | AgSnO2 |
Maximum Switching Voltage | 250 V AC/DC |
Minimum Switching Voltage | 5 V AC/DC |
Limiting Continuous Current | 6 A (N/O contact) |
Limiting Continuous Current | 3 A (N/C contact 11/12) |
Limiting Continuous Current | 6 A (N/C contact 71/72) |
Maximum Inrush Current | 6 A |
Inrush current, minimum | 10 mA |
Sq. Total current | 72 A2 (ITH2 = I12 + I22 + ... + I52) |
Switching capacity min. | 50 mW |
Switching capacity in accordance with IEC 60947-5-1 | 3 A (AC15) |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (DC13) |
Output fuse | 10 A gL/gG (N/O contact) |
Output fuse | 6 A gL/gG (N/C contact) |
Relay
Interrupting rating (ohmic load) max. | see load limit curve |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
Operating voltage display | 2 x green LED |
Dimensions
Width | 35 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 (In conjunction with suitable evaluating device) |
Performance level (PL) | e (In conjunction with suitable evaluating device) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
Air clearances and creepage distances between the power circuits
Standards/regulations | EN 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | Observe derating |
Mounting Position | vertical or horizontal |
Why Proax for Phoenix Contact 2963734?
Proax is an authorized distributor of Phoenix Contact 2963734 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |