Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSR-SCP- 24UC/ESAM4/2X1/1X2
Weight
0.193 kg
Series PSR-SCP

PSR-SCP- 24UC/ESAM4/2X1/1X2 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 2-channel operation, 2 enabling current paths, nominal input voltage: 24 V DC, plug-in screw terminal block

  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
  • Manually monitored and automatic activation in a single device
  • Reinforced insulation
  • 2 channel control
  • 2 enabling current paths, 1 signaling current path
Technical Specifications

Product properties

Product familyPSRclassic
ApplicationEmergency stop
ApplicationSafety door
Mechanical service lifeapprox. 107 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Electrical properties

Maximum power dissipation for nominal condition16.44 W (US = 26.4 V, IL² = 72 A², PTotal max = 2.04 W + 14.4 W)
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V
Rated surge voltage/insulationSee section “Insulation coordination”

General

Rated control circuit supply voltage US24 V DC -15 % / +10 %
Power consumption at UStyp. 1.68 W (DC)
Rated control supply current IStyp. 70 mA
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN70 mA DC (at Us)
Inrush Current< 3.5 A (Δt = 3 ms at Us)
Inrush Current< 100 mA (Δt = 500 ms, with Us/Ix at S12)
Inrush Current> -100 mA (Δt = 300 ms, with Us/Ix at S22)
Inrush Current< 6 mA (with Us/Ix to S34)
Inrush Current< 6 mA (with Us/Ix to S35)
Current consumptiontyp. 38 mA (S12)
Current consumptiontyp. -38 mA (S22)
Current consumptiontyp. 0 mA (with Us/Ix to S34)
Current consumptiontyp. 1 mA (with Us/Ix to S35)
Voltage at input/start and feedback circuitapprox. 24 V DC
Filter time5 ms (at A1 in the event of voltage dips at Us)
Filter timeNo test pulses permitted
Typical response time100 ms (Monitored/manual start)
Typical response time150 ms (automatic start)
Typ. starting time with Us250 ms (when controlled via A1)
Typical release time20 ms (on demand via the sensor circuit)
Typical release time45 ms (on demand via A1)
Concurrence
Recovery time1 s (following demand of the safety function)
Recovery time< 1 s (Boot time)
Protective circuitSurge protection; Suppressor diode
Max. permissible overall conductor resistanceapprox. 50 Ω (Input and start circuits at US)
Operating voltage displayGreen LED
Status displayGreen LED

Output data

Contact switching type2 enabling current paths
Contact switching type1 signaling current path
Contact MaterialAgSnO2, + 0.2 µm Au
Maximum Switching Voltage250 V AC
Minimum Switching Voltage10 V AC/DC
Limiting Continuous Current6 A (Observe derating and load limit curve)
Maximum Inrush Current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2 (Enabling current paths)
Sq. Total current36 A2 (Signaling current path 31/32)
Interrupting rating (ohmic load) max.see load limit curve
Switching capacity min.100 mW
Switching capacity in accordance with IEC 60947-5-16 A (DC13, enabling current paths)
Switching capacity in accordance with IEC 60947-5-15 A (AC15, enabling current paths)
Switching capacity in accordance with IEC 60947-5-12 A (DC13, signaling current paths)
Switching capacity in accordance with IEC 60947-5-11.5 A (AC15, signaling current paths)
Output fuse10 A gL/gG (Enabling current paths)
Output fuse4 A gL/gG (Low-demand enabling current paths)
Output fuse6 A gL/gG (Signaling current path)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category4
Performance level (PL)e (5 A DC13; 5 A AC15; 8760 switching cycles/year)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)3

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 60947-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact 2900525?

Proax is an authorized distributor of Phoenix Contact 2900525 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability