Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
UM-2KS50/32RM/MR/21/SPT/CS/C-L
Series UM

UM-2KS50/32RM/MR/21/SPT/CS/C-L - Active module

32-channel relay module for Yokogawa ADV 551 and ADV 561 digital output modules. Redundant system connection, spring-cage connection on the field side. Pluggable relays with status indicator (LED) per channel.

Technical Specifications

Product properties

No. of channels32
Operating mode100% operating factor
Mechanical service lifeapprox. 2x 10⁷ cycles

Insulation characteristics

InsulationSafe isolation, reinforced insulation

Insulation characteristics: Air clearances and creepage distances, input/output

InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree2

Insulation characteristics: Air and creepage distances, output/output

InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2

Air clearances and creepage distances, input/output

Rated Insulation Voltage300 V
Rated surge voltage6 kV (1.2/50 μs)

Air and creepage distances, output/output

Rated Insulation Voltage300 V
Rated surge voltage4 kV (1.2/50 μs)

Supported controller YOKOGAWA CS3000 CentumVP

Suitable I/O cardADV551
Suitable I/O cardADV561

Supported controller YOKOGAWA STARDOM

Suitable I/O cardNFDV551
Suitable I/O cardNFDV561

Input data

Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.8 ... 1.2
Input voltage range19.2 V DC ... 28.8 V DC
Typical input current at UN9 mA (Per relay (K1 ... K32))
Typical response time5 ms (K1 – K32)
Typical response time5 ms (K33)
Typical release time7 ms (K1 – K32)
Typical release time5 ms (K33)
Protective circuitPolarity protection diode
Protective circuitFreewheeling diode
Protective circuitFuse
Operating voltage displayGreen LED
Status display/channelYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgSnO
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage12 V AC/DC
Limiting Continuous Current4 A (see derating curve)
Min. switching current10 mA
Interrupting rating (ohmic load) max.96 W (24 V DC)
Interrupting rating (ohmic load) max.20 W (48 V DC)
Interrupting rating (ohmic load) max.18 W (60 V DC)
Interrupting rating (ohmic load) max.23 W (110 V DC)
Interrupting rating (ohmic load) max.40 W (220 V DC)
Interrupting rating (ohmic load) max.1000 VA (250 V AC)

Field level

Connection MethodSpring-cage connection
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Controller level

Connection MethodYokogawa KS-compatible
Number of Connections2
Number of Positions50
NoteUsable system cables: Phoenix Contact YUC50, Yokogawa AKB331
Tightening torque0.5 Nm

Supply

Connection MethodPush-in connection
Stripping length10 mm
Number of Connections1
Number of Positions6
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Pitch5.08 mm

Signaling

Status display presentYes

Dimensions

Width505.5 mm
Height125.5 mm
Depth60 mm

Ambient conditions

Degree of ProtectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient Temperature (Operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C
Altitude≤ 2000 m

Air clearances and creepage distances, input/output

Standards/regulationsEN 61010-2-201

Air and creepage distances, output/output

Standards/regulationsEN 61010-2-201

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany

Notes

Notes on operationObserve the maximum switching capacity of the relays used
Notes on operationDo not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
Notes on operationThe outputs are not suitable for switching different line conductors. The sum of the switching voltages used for adjacent outputs must not exceed the rated insulation voltage value
Notes on operationThe necessary requirements for insulation (basic insulation or reinforced insulation) from adjacent modules (in DIN-rail direction) must be realized by applying suitable measures (e. g., partition plates).
Notes on operationFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Why Proax for Phoenix Contact 2968535?

Proax is an authorized distributor of Phoenix Contact 2968535 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability