MACX MCR-EX-SL-RPSS-2I-2I-SP - Repeater power supply

Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.

  • 2-channel
  • 4 mA ... 20 mA input, intrinsically safe, [Ex ia], powered
  • Output 4 mA ... 20 mA, active
  • HART-compatible
  • Error indication according to NAMUR NE 43
  • Up to SIL 3 according to IEC/EN 61508
  • 5-way electrical isolation
  • Power supply possible via DIN rail connector
  • Installation in Ex zone 2 permitted
  • Plug-in connection terminals, push-in connection technology
  • Housing width: 12.5 mm
  • Minimal power dissipation
  • High transmission accuracy
Technical Specifications

Product properties

Product familyMACX Analog
ApplicationAnalog IN
No. of channels2
TypeEx i signal conditioners with SIL and PL Functional Safety

Electrical properties

Electrical isolation5-way isolation
Electrical isolation between input and outputyes
Signal transmission behaviorIn = Out
Step response (10-90%)< 1.3 ms (for 4 mA ... 20 mA step)
Maximum temperature coefficient< 0.01 %/K
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)

Electrical isolation

Overvoltage categoryII
Pollution degree2

Electrical isolation Input/output, power supply IEC/EN 61010-1

Standards/regulationsIEC/EN 61010-1
Rated Insulation Voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation

Electrical isolation Input/output IEC/EN 60079-11

Standards/regulationsIEC/EN 60079-11
Rated Insulation Voltage265 Vrms

Electrical isolation Input/power supply IEC/EN 60079-11

Standards/regulationsIEC/EN 60079-11
Rated Insulation Voltage265 Vrms

Electrical isolation Output 1/output 2/ power supply

Test voltage1.5 kV AC (50 Hz, 60 s)

Supply

Nominal Supply Voltage24 V DC -20 % ... +25 %
Supply Voltage Range19.2 V DC ... 30 V DC
Max. current consumption< 100 mA (24 V DC / 20 mA)
Power dissipation< 1.4 W (24 V DC / 20 mA)
Power consumption≤ 2.4 W

Signal: Current

Description of the inputIntrinsically safe
Number of Inputs2
Current Input Signal4 mA ... 20 mA
Transmitter supply voltage> 16 V (20 mA)
Underload/overload signal range0 mA ... 24 mA
Output descriptionCurrent output
Number of Outputs2
Current Output Signal4 mA ... 20 mA (active)
Load/Output Load Current Output≤ 450 Ω (20 mA)
Load/Output Load Current Output≤ 375 Ω (24 mA)
Output behavior in the event of an error< 3.6 mA (In the event of cable break at the input (as per NE 43))
Output behavior in the event of an error> 22.5 mA (In the event of cable short circuit at the input (as per NE 43))
Underload/overload signal range0 mA ... 24 mA

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section flexible (2 conductors with same cross section)0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG24 ... 14
Conductor cross section AWG24 ... 22 (TWIN ferrule without plastic sleeve)
Conductor cross section AWG20 ... 16 (TWIN ferrule with plastic sleeve)

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2
Ex i circuits (EPL)Ga
Ex i circuits (EPL)Da
Ex i circuits (EPL)Ma
Ex i circuits (EPL)Div. 1

Safety data

Max. output voltage Uo25.2 V
Max. output current Io93 mA
Max. output power Po587 mW
Safety-related maximum voltage Um253 V AC
Safety-related maximum voltage Um125 V DC
I (simple circuit): Max. external inductivity Lo / Max. external capacitance Co40 mH / 4.8 µF
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co26 mH / 2.9 µF
IIB (simple circuit): Max. external inductivity Lo / Max. external capacitance Co14 mH / 820 nF
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co3 mH / 107 nF
IIA (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co26 mH / 470 nF, 20 mH / 570 nF, 1 mH / 630 nF, 0.5 mH / 720 nF, 0.1 mH / 1.1 µF, 0.005 mH / 2.9 µF
IIB/III (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co16 mH / 370 nF, 500 µH / 510 nF, 200 µH / 660 nF, 100 µH / 820 nF
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co2.2 mH / 47 nF, 2 mH / 49 nF, 1 mH / 63 nF, 500 µH / 80 nF, 200 µH / 107 nF
I (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co37 mH / 0.54 µF, 0.35 mH / 1 µF, 0.009 mH / 2.9 µF, 0.001 mH / 4.15 µF

Data communication (bypass)

HART FunctionYes
Protocols SupportedHART-transparent

Signaling

Status displayGreen LED (supply voltage)

Dimensions

Width12.5 mm
Height107.9 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 60 °C (Any mounting position)
Ambient Temperature (Operation)-40 °C ... 70 °C (Derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)

Altitude range (≤ 2000 m)

Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Ambient Temperature (Operation)-40 °C ... 60 °C
Ambient Temperature (Operation)-40 °C ... 70 °C (Derating)
Rated Insulation Voltage375 VPP (Power supply, input / output)

Altitude range (≤ 3000 m)

Height Range> 2000 m ... 3000 m
Ambient Temperature (Operation)-40 °C ... 54 °C
Ambient Temperature (Operation)-40 °C ... 63 °C (Derating)
Rated Insulation Voltage190 V AC (Power supply, input / output)
Rated Insulation Voltage110 V DC (Power supply, input / output)

Altitude range (≤ 4000 m)

Height Range> 3000 m ... 4000 m
Ambient Temperature (Operation)-40 °C ... 48 °C
Ambient Temperature (Operation)-40 °C ... 56 °C (Derating)
Rated Insulation Voltage60 V AC/DC (Power supply, input / output)

Altitude range (≤ 5000 m)

Height Range> 4000 m ... 5000 m
Ambient Temperature (Operation)-40 °C ... 42 °C
Ambient Temperature (Operation)-40 °C ... 49 °C (Derating)
Rated Insulation Voltage60 V AC/DC (Power supply, input / output)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification II (1) G [Ex ia Ga] IIC
Identification II (1) D [Ex ia Da] IIIC
Identification II 3(1) G Ex ec [ia Ga] IIC T4 Gc
Identification I (M1) [Ex ia Ma] I
CertificateBVS 10 ATEX E 143 X

IECEx

Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
IdentificationEx ec [ia Ga] IIC T4 Gc
Identification[Ex ia Ma] I
CertificateIECEx BVS 10.0097X

CCC / China-Ex

Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
IdentificationEx ec [ia Ga] IIC T4 Gc
Certificate2022122316115972

UL, USA/Canada

IdentificationIS for Class I, II, III Div 1
IdentificationClass I, Div. 2
Certificate, C.D.-No 83104549
IdentificationClass I Div 2; IS for Class I, II, III Div 1
Certificate, C.D.-No 83104549

KC-s

Identification[Ex ia] IIC/IIB
Certificate17-KA4BO-0401X

Shipbuilding approval

CertificateDNV GL TAA000020C

Safety Integrity Level (SIL, IEC 61508)

Identification3

Performance Level (ISO 13849)

Identificationd

INMETRO

Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
IdentificationEx ec [ia Ga] IIC T4 Gc
CertificateDNV 18.0140 X

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Standards and Regulations

Electrical isolation5-way isolation

GB Standard

Standards/regulationsGB/T 3836.1
Standards/regulationsGB/T 3836.3
Standards/regulationsGB/T 3836.4

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2924676?

Proax is an authorized distributor of Phoenix Contact 2924676 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability