MPN
MACX MCR-EX-SL-SD-21-60-LP
Weight
0.173 kg
This product is Not Cancellable/Not Returnable

MACX MCR-EX-SL-SD-21-60-LP - Solenoid driver

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.

  • Mechanically compatible with the DIN rail connector
  • Various output characteristic curves compatible with standard solenoid valves
  • Loop-powered: the required power is supplied via the control signal on the input side.
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Up to SIL 3 in accordance with IEC 61508
  • 2-way electrical isolation
  • Input: 19.2 V DC … 30 V DC
  • Output [Ex ia] IIB
Technical Specifications

Product properties

Product familyMACX Analog
No. of channels1
TypeEx i signal conditioners with SIL functional safety
Compatible ValveASCO Coil 302 (12 V)
Compatible ValveASCO Coil 302 (24 V)
Compatible ValveBürkert Coil AC 10 standard
Compatible ValveBürkert Coil AC 10 high resistance
Compatible ValveFESTO Coil MFH-...IA-SA-EX GBXE022AIAD03
Compatible ValveFESTO Coil (J)MFH-...BIA-SA-EX GBXE022AIAD03
Compatible ValveNorgren Herion Coil 2050
Compatible ValveNorgren Herion Coil 2051
Compatible ValveNorgren Herion Coil 2052
Compatible ValveNorgren Herion Coil 2053
Compatible ValveParker Coil VZ95 482160.01 EEx ia IIB T6
NoteThis is an extract of possible combinations of valves and solenoid drivers.

Electrical properties

Electrical isolation2-way isolation
Maximum temperature coefficient0.01 %/K

Electrical isolation

Test voltage2.5 kV AC (50 Hz, 60 s)
Overvoltage categoryII
Pollution degree2

Electrical isolation Output/input IEC/EN 60079-11

Standards/regulationsIEC/EN 60079-11
Rated Insulation Voltage375 VPP

Electrical isolation Output/input IEC/EN 61010-1

Standards/regulationsIEC/EN 61010-1
Rated Insulation Voltage300 Vrms
InsulationSafe isolation

Supply

Supply Voltage Rangeloop-powered, no external supply necessary
Power dissipation< 1.325 W

Signal: Voltage

Number of Inputs1
Voltage input signal19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current input signal95 mA (Ue = 24 V DC)
Output descriptionintrinsically safe
Number of Outputs1
Output Voltage12.9 V DC (58 mA)
Output resistor133.4 Ω (Internal resistance Ri)
Current limitation58 mA
Response time20 ms
Non-load voltage21.9 V DC
Short-circuit-proofyes

Connection data

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Test socket

Max. diameter2 mm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2
Ex i circuits (EPL)Ga
Ex i circuits (EPL)Da
Ex i circuits (EPL)Ma
Ex i circuits (EPL)Div. 1

Safety data

Max. internal inductance Linegligible
Max. internal capacitance Cinegligible
Max. output voltage Uo25.1 V
Max. output current Io188 mA
Max. output power Po1.18 W
Safety-related maximum voltage Um253 V AC
Safety-related maximum voltage Um125 V DC
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co4 mH / 0.83 µF
IIB/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co2 mH / 300 nF, 1 mH / 370 nF, 0.5 mH / 460 nF, 0.1 mH / 790 nF

Signaling

Status displayYellow LED (switching state / status, lights up when output circuit is active)

Dimensions

Width12.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Degree of ProtectionIP20 (not assessed by UL)
Ambient Temperature (Operation)-40 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification II (1) G [Ex ia Ga] IIB/IIA
Identification II (1) D [Ex ia Da] IIIC
Identification II 3 (1)G Ex nA [ia IIB Ga] IIC T4 Gc X
CertificateIBExU 07 ATEX 1133X

UKCA Ex (UKEX)

Identification I (M1) [Ex ia Ma] I
Identification II (1) G [Ex ia Ga] IIB
Identification II (1) D [Ex ia Da] IIIC
Identification II 3 (1) Ex ec [ia IIB Ga] IIC T4 Gc
CertificateCML 22UKEX3526X

IECEx

Identification[Ex ia Ga] IIB/IIA
Identification[Ex ia Da] IIIC
IdentificationEx nA [ia IIB Ga] IIC T4 Gc
CertificateIECEx IBE 08.0002X

CCC / China-Ex

Identification[Ex ia Ga] IIC
Identification[Ex iaD]
IdentificationEx nA [ia Ga] IIC T4 Gc
CertificateNEPSI GYJ20.1316X

UL, USA/Canada

IdentificationUL 61010 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T4
IdentificationClass I, Div. 2, Groups IIC, IIB, IIA T4
IdentificationAssociated apparatus for use in Class I, Division 1, Groups C,D
IdentificationAssociated apparatus for use in Class II, Div.1 Groups E,F,G
IdentificationAssociated apparatus for use in Class III, Division 1
IdentificationAssociated apparatus for use in Class I, Zone 0,1,2, Groups IIB, IIA
Certificate, C.D.-No 83104549
IdentificationClass I Div 2; IS for Class I, II, III Div 1
Certificate, C.D.-No 83104549

Shipbuilding approval

CertificateDNV GL TAA000020C

Safety Integrity Level (SIL, IEC 61508)

Identification3

INMETRO

Identification[Ex ia Ga] IIC/IIB/IIA
Identification[Ex ia Da] IIIC
IdentificationEx nA [ia IIC Ga] IIC T4 Gc
CertificateDNV 18.0115 X

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Standards and Regulations

Electrical isolation2-way isolation

GB Standard

Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.4
Standards/regulationsGB 3836.8
Standards/regulationsGB 3626.20
Standards/regulationsGB 12476.1
Standards/regulationsGB 12476.4

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2865515?

Proax is an authorized distributor of Phoenix Contact 2865515 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability