MACX MCR-EX-SL-RTD-I-SP-NC - Temperature measuring transducer
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, spring-cage terminal blocks. Replacement item: 1050252 MACX MCR-EX-RTD-I-SP.
- Power supply possible via DIN rail connector
- Programming during operation with Ex measuring circuit connected and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
- Input for resistance thermometers and resistance-type sensors, [Ex ia] IIC
- Installation in zone 2, protection type "n" (EN 60079-15) permitted
- 3-way electrical isolation
- Output: 0 mA ... 20 mA or 4 mA ... 20 mA
- Status indicator for supply voltage, cable, sensor, and module errors
- Configuration via software (FDT/DTM): sensor type, connection technology, measuring range, measuring unit, filter, alarm signal, and output range
Technical Specifications
Product properties
| Application | Temperature |
| No. of channels | 1 |
| Type | Ex i signal conditioners |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Alignment span | ± 5 % |
| Alignment zero | ± 5 % |
| Electrical isolation | 3-way isolation |
| Step response (0–99%) | 700 ms |
| Step response (0–99%) | ≤ 1100 ms |
| Temperature coefficient, typical | 0.01 %/K |
Electrical isolation Input/output/power supply
| Rated Insulation Voltage | 300 Vrms |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Insulation | Safe isolation in accordance with IEC/EN 61010-1 |
Electrical isolation Input/output
| Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Electrical isolation Input/power supply
| Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Supply
| Nominal Supply Voltage | 24 V DC |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
| Power dissipation | < 1 W |
Signal
| Number of Inputs | 1 |
| Input Signal | Temperature |
| Input Signal | Resistor |
Measurement
| Description of the input | Intrinsically safe |
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
| Temperature measuring range | -200 °C ... 850 °C (Range depending on the sensor type) |
| Linear resistance measuring range | 0 Ω ... 2000 Ω |
| Max. permissible overall conductor resistance | 50 Ω (Per cable) |
| Sensor input current | 200 µA ... 1 mA |
| Temperature measuring range | min. 50 K |
Switching:
| Configurable/programmable | no |
Signal
| Output description | Current output |
| Number of Outputs | 1 |
| Configurable/programmable | Yes |
| Current Output Signal | 0 mA ... 20 mA |
| Current Output Signal | 4 mA ... 20 mA |
| Load/Output Load Current Output | ≤ 500 Ω |
| Output ripple (current) | < 50 µAPP |
| Output ripple (current) | < 10 µArms |
| Behavior in the event of a sensor error | As per NE 43 or can be freely defined |
Connection data
| Connection Method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
Safety data
| Max. output voltage Uo | 6 V |
| Max. output current Io | 6.3 mA |
| Max. output power Po | 9.4 mW |
| Safety-related maximum voltage Um | 253 V AC |
| Safety-related maximum voltage Um | 125 V DC |
| IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 100 mH / 1.4 µF, 10 mH / 1.9 µF, 1 mH / 2.7 µF |
| IIB (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 100 mH / 6.9 µF, 10 mH / 9.4 µF, 1 mH / 15 µF |
| IIA (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 100 mH / 10 µF, 10 mH / 13 µF, 1 mH / 21 µF |
Signaling
| Status display | Green LED (supply voltage, PWR) |
| Status display | Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR) |
| Status display | Red LED, flashing 1.2 Hz (service operation, ERR) |
| Status display | Red LED, permanently on (module error, ERR) |
Dimensions
| Width | 12.5 mm |
| Height | 116 mm |
| Depth | 114.5 mm |
Material specifications
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 (Housing) |
| Housing Material | PA 6.6-FR |
Ambient conditions
| Degree of Protection | IP20 (not assessed by UL) |
| Ambient Temperature (Operation) | -20 °C ... 60 °C (Any mounting position) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
| Note | and EN 61326 |
ATEX
| Identification | II (1) G [Ex ia Ga] IIC/IIB |
| Identification | II (1) D [Ex ia Da] IIIC |
| Identification | II 3(1) G Ex nA ic [ia Ga] IIC T4 Gc X |
| Certificate | IBExU 09 ATEX 1013 |
IECEx
| Identification | [Ex ia Ga] IIC |
| Identification | [Ex ia Da] IIIC |
| Identification | Ex nA ic [ia Ga] IIC T4 Gc |
| Certificate | IECEx IBE 09.0001X |
UL, USA/Canada
| Identification | Class I Div 2; IS for Class I, II, III Div 1 |
| Certificate | , C.D.-No 83104549 |
KC-s
| Identification | [Ex ia] IIC/IIB |
| Certificate | 17-KA4BO-0414X |
Shipbuilding approval
| Identification | C, EMC1 |
| Certificate | GL 86 644-10HH |
EAC Ex
| Identification | [Ex ia Ga] IIC |
| Identification | [Ex ia Da] IIIC |
| Certificate | RU C-DE.AB72.B.00093/19 |
INMETRO
| Identification | [Ex ia Ga] IIC |
| Identification | [Ex ia Da] IIIC |
| Identification | Ex nA [ia Ga] IIC T4 Gc |
| Certificate | DNV 18.0142 X |
EMC data
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 |
Electromagnetic HF field
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
Fast transients (burst)
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
Conducted interference
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
Standards and Regulations
| Electrical isolation | 3-way isolation |
Mounting
| Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2924168?
Proax is an authorized distributor of Phoenix Contact 2924168 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended