Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
AXL F AI4 U XC 1H
Weight
0.219 kg
This product is Not Cancellable/Not Returnable
Series AXL-F-AI

AXL F AI4 U XC 1H - Analog module

Axioline F, Analog input module, Analog inputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, connection technology: 2-, 3-, 4-conductor, transmission speed in the local bus: 100 Mbps, integrated sensor supply, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors

  • 4 analog, bipolar input channels for the connection of voltage signals
  • Connection of sensors in 2-, 3-, and 4-conductor technology
  • Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V
  • Simultaneous scanning of all channels by means of simultaneous sampling
  • High crosstalk attenuation between the channels, thanks to separate signal paths
  • Particularly robust against electromagnetic interference
  • Device rating plate stored
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Partially coated PCBs
Technical Specifications

Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area8 Byte
Output address area8 Byte
Required parameter data 7 Byte
Required configuration data 6 Byte

Analog: General

Input nameAnalog inputs
Description of the inputDifferential inputs, voltage
Number of Inputs4
A/D conversion time31.25 µs
A/D converter resolution16 bit
Connection MethodPush-in connection
Connection technology2-, 3-, 4-conductor
Note regarding the connection technologyshielded, twisted pair
Voltage input signal0 V ... 5 V
Voltage input signal-5 V ... 5 V
Voltage input signal0 V ... 10 V
Voltage input signal-10 V ... 10 V
Input resistance of voltage input268 kΩ (typical)
Data formatsIB IL, S7-compatible
Input filter30 Hz, 12 kHz and mean-value generation (can be parameterized)
Limit frequency (3 dB)30 Hz
Limit frequency (3 dB)12 kHz
Common mode voltage range signal - ground-50 V DC ... 50 V DC
Measured value representation16 bits (15 bits + sign bit)
Protective circuitTransient protection of inputs; Suppressor diode
Protective circuitOverload protection of the voltage inputs; ±30 V DC, maximum

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special Propertiesintegrated sensor supply
Special PropertiesExtreme conditions version

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials

Power consumptiontyp. 1.51 W (Device, total, plus the power consumption of the external sensors)
Power consumptionmax. 1.78 W (Device, total, plus the power consumption of the external sensors)

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 150 mA
Current drawtyp. 120 mA
Power consumptionmax. 0.75 W
Power consumptiontyp. 0.6 W

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC (I/O supply and sensor supply)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 245 mA (IiS = 4 x 50 mA (full load))
Current drawmax. 45 mA (IiS = 0 mA)
Current drawtyp. 118 mA (IiS = 4 x 20 mA (nominal load))
Current drawmax. 125 mA (IiS = 4 x 20 mA (nominal load))
Current drawtyp. 238 mA (IiS = 4 x 50 mA (full load))
Power consumptionmax. 5.88 W (Full load)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; up to HW 02: polarity protection diodefrom HW 03: parallel diode; with external 5 A fuse (for startup only)
Protective circuitTransient protection; Suppressor diode

Supply:

DesignationSensor supply UiS
Supply Voltage24 V DC (from UA)
Current consumptionmax. 50 mA (per channel)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog inputs500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Analog inputs/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

ATEX

Identification II 3 G Ex ec IIC T4 Gc
CertificateUL 20 ATEX 2441X
References to standardsEN IEC 60079-0, EN IEC 60079-7

UKEX

Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2701949X
References to standardsEN IEC 60079-0, EN IEC 60079-7

IECEx

IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 20.0026X
References to standardsIEC 60079-0 Ed. 7, IEC 60079-7 Ed. 5.1

UL, USA/Canada

IdentificationcULus
CertificateE238705

UL Ex, USA / Canada

IdentificationClass I, Zone 2, AEx ec IIC T4
IdentificationClass I, Division 2, Groups A, B, C, D, T4
IdentificationEx ec IIC T4 Gc X
CertificateE366272
References to standardsUL 60079-0 Ed. 7 / CSA C22.2 NO. 60079-0 Ed. 4
References to standardsUL 60079-7 Ed. 5 / CSA C22.2 NO. 60079-7 Ed. 2

CCC / China-Ex

IdentificationEx ec IIC T4 Gc
Certificate, 2021122309114456
References to standardsGB/T 3836.1-2021, GB/T 3836.3-2021

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact 2702008?

Proax is an authorized distributor of Phoenix Contact 2702008 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability