MPN
AXL F AO4 1H
Weight
0.197 kg
Series AXL-F-AO

AXL F AO4 1H - Analog module

Axioline F, Analog output module, Analog outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

  • 4 analog output channels for the connection of either voltage or current signals
  • Bipolar voltage outputs, unipolar current outputs
  • Connection of actuators in 2-conductor technology
  • Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V
  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA
  • Short-circuit-proof outputs
  • No derating in all ranges
  • Short signal rise times
  • Driving of high loads
  • Device rating plate stored
Technical Specifications

Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Note on application

Note on applicationOnly for industrial use

Axioline F local bus

Number of interfaces2
Connection MethodBus base module
Transmission Speed100 Mbps

Module

Input address area8 Byte
Output address area8 Byte
Required parameter data 14 Byte
Required configuration data 7 Byte

Analog:

Output nameAnalog outputs
Connection MethodPush-in connection
Connection technology2-conductor
Note regarding the connection technologyshielded, twisted pair
Number of Outputs4
D/A converter resolution16 bit
Protective circuitShort-circuit and overload protection; electronic
Protective circuitTransient protection; Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values16 bits (15 bits + sign)
Process data update140 µs
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Load/Output Load Current Output≤ 500 Ω
Voltage output signal0 V ... 5 V
Voltage output signal-5 V ... 5 V
Voltage output signal0 V ... 10 V
Voltage output signal-10 V ... 10 V
Load/output load voltage output≥ 1 kΩ

Product properties

Product familyAxioline F
Typeblock modular
Mounting Positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition3.4 W

Potentials: Axioline F local bus supply (UBus)

Supply Voltage5 V DC (via bus base module)
Current drawmax. 150 mA
Current drawtyp. 120 mA

Potentials: Supply for analog modules (UA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 125 mA (4 current channels, 24 mA output, 500 Ω load)
Current drawtyp. 60 mA (4 voltage channels, 10 V output)
Current drawmax. 85 mA (4 voltage channels, 10 V output)
Current drawmax. 110 mA (4 current channels, 20 mA output, 500 Ω load)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitTransient protection; Suppressor diode

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply of the local bus (UBus)/analog outputs500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (I/O)/analog outputs500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min
Test voltage: Analog outputs/functional ground500 V AC, 50 Hz, 1 min

Connection technology

Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Axioline F connector

Connection MethodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany (no temperature derating)
Accessories

Why Proax for Phoenix Contact 2688527?

Proax is an authorized distributor of Phoenix Contact 2688527 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability